air conditioning control Articles

  • Energy Saving in Air Conditioning is a must!

    Energy Efficiency is now a must! Air Conditioning in residential and commercial buildings is the largest single consumer of electricity so tenants and owners are now looking for ways to reduce their air conditioning energy costs. EnviroTech, a company based in the UAE, Oman, KSA and South America with all products Made in England, is ...


    By EnviroTech Limited

  • Air Conditioning That`s Out of This World

    New materials enhance the cooling effects from outer space to reduce energy use in small- to medium-sized buildings Reducing air conditioning energy use by using new materials to enhance the cooling effects from outer space may not be such a far-out idea. In a simulation study using DOE's Energy Plus software and ...


    By US Department of Energy

  • Simultaneous determination of PM fractions, particle number and particle size distribution in high time resolution applying one and the same optical measurement technique

    Abstract The Fidas fine dust monitoring systems comprise an optical aerosol spectrometer, which is characterized by very good instrument characteristics, and utilize a sophisticated approach to convert the measured information on particle number and particle size into mass concentrations. As monitoring of PM requires reliable and quality-controlled performance of the measuring systems, ...


    By Palas GmbH

  • Reduced Emissions for Landfill Gas Installations

    The use of landfill gas as a source of renewable energy is increasing. For environmental and safety reasons, the owners of the waste storage sites have to strictly monitor and control the construction, operations, and emissions generated. Sulzer offers solutions to control these emissions within the limits given by the government. Landfill gas is similar to natural gas, but it is created by ...


    By Sulzer

  • Self–tuning fuzzy PID decoupling controller for VAV air–conditioning system

    One of the most important challenges in nonlinear, multi–input and multi–output (MIMO) and time variant systems is designing a controller with acceptable performance. This paper focuses on design a new adaptive fuzzy PID decoupling controller, applied in the VAV air–conditioning system. In this approach, the PID parameters are adjusted by fuzzy rules. Diagonal matrix decoupling method is employed ...


    By Inderscience Publishers

  • Netherlands’ Mobile Emergency Pumps Provide Rapid Flood Response

    The Western European nation has 20 mobile diesel-driven pumps on standby, ready to assist in national and international emergencies. One of the smallest and most densely populated countries in Western Europe, the Netherlands has nearly 10 million residents who live and work below sea level. Without active water management and primary flood defenses, ...


    By BBA Pumps

  • BBA Mobile Emergency Pumps Provide Rapid Response for Floods

    Netherlands’ Mobile Emergency Pumps Provide Rapid Flood Response In its latest edition, the North American PUMPS & SYSTEMS magazine publishes an in-depth article featuring the history and current usage of emergency mobile pumps. The Western European ...


    By BBA Pumps

  • Smart operation of air-conditioning (A/C) and lighting systems for national load management

    In the countries of Arabian Peninsula, demand for electric power, primarily controlled by the air-conditioning (A/C) and generally peaking at 15:00 h, is currently growing well over 5% annually. Adaptations of smart operation of A/C and lighting systems in government and institutional buildings that commonly function between 07:00 h and 14:00 h has been evaluated as a technique for national load ...


    By Inderscience Publishers

  • Policy influence of formaldehyde exposure risk in air-conditioned office environment

    Long-term measurement of indoor air quality (IAQ) over a general community could be a good approach to evaluate the influence of policy on pollutant exposure levels. However, this approach requires considerable measurement efforts and in many circumstances an updated data set will not be available. Formaldehyde is an indoor pollutant that presents a health hazard to building occupants in the long ...


    By SAGE Publications

  • From air conditioning to urban planning, defaults and standards create dysfunction by design

    How can we stop outdated assumptions from forcing us to waste? Personal heaters are a summer survival tool for many office workers chilled to the bone by hyperactive ventilation systems — an act of self-defense against an epidemic of overcooling that is wasting energy and confounding comfort in not only offices but also large shops, schools and other buildings. An audit ...


    By Ensia

  • Performance evaluation of multi-passive solar applications of a non air-conditioned building

    This paper describes the performance evaluation of solar passive cooling techniques such as solar shading insulation of building components and air exchange rate. Thermal performance of the non air-conditioned building is predicted by analysing a one-dimensional numerical model. Numerical calculation has been made corresponding to three different climates, viz. composite, hot and dry and warm and ...


    By Inderscience Publishers

  • Fires at Composting Facilities: Causes and Conditions

    The subject of fires at composting facilities is a bad news/good news situation. The bad news is that fires are more common than we realize. Ask a group of facility operators if they have had to deal with a fire, and the majority will quietly admit they have. The good news is that we don’t realize that fires are fairly common at composting facilities. Most are neither frequent nor destructive ...


    By BioCycle Magazine

  • Using Rn-222 to manage the air quality of air conditioned buildings in Hong Kong

    This paper proposes a pragmatic methodology to manage the air quality of an air conditioned building as well as optimizing energy consumption during venting. Radon-222 (Rn-222) is used as a tracer to quantify the specific production rates and resultant losses of pollutants for which the information is important in indoor air quality management. A term, indoor pollutant inventory, is introduced ...


    By SAGE Publications

  • Integrated maximum efficiency air pollution control system

    A major uranium refiner required an air pollution control system to control emissions from their hazardous incinerator. The presence of radioactive material demanded that outlet emissions approach non-detectable levels. Macrotek was contracted to design and supply the system. Advanced, cutting edge technology was used to design a system with the lowest possible emissions, which has been ...


    By Macrotek Inc.

  • Maintenance solutions for air pollution control equipment

    Manufacturing facilities are constantly under pressure to meet production forecasts at the lowest possible cost. These two goals; production output and cost control, can be difficult to obtain consistently in any manufacturing operation. Additional frustration to meet these goals can be exaggerated in today’s lean manufacturing climates that have trimmed budgets and reduced workforce. ...

  • Time to address the air pollution control residue problem

    The incineration of municipal solid waste is gaining increasing importance in the UK, especially as the burning of waste can be used to generate energy, providing a more sustainable solution to our waste problem by diverting it from landfill sites. An issue with incineration is that some of our waste contains hazardous chemicals such as chlorine and lead which are volatilised during the process. ...

  • Efficient Operation of Lighting, Hot Water and Air Conditioning: Hotel Inter Continental Sydney

    To improve its environmental performance and save nearly $300,000 per year, the Hotel Inter Continental Sydney changed some practices that seemed insignificant in themselves but which collectively, wasted massive resources. The changes cost around $275,000 and no adverse affect on guest amenity. They included lowering the power of lights that were too bright, lowering the temperature of ...


  • Air Pollution Control: Ready for the 21st Century

    The textile industry is plagued by air pollution problems which must be resolved. In particular, smoke and odor arising in the process require abatement. Air pollution control technology is available today which will serve the textile industry well into the 21st century. The nature of the problem The major air pollution problem in the textile industry occurs during the finishing stages, ...


  • The implement of the electro-static and magnetic precipitation technique through the centeral air-conditioning systems

    In this paper we will introduce the electrostatic and magnetic precipitation technique, to deposit the solid dust within the air–conditioning systems .Recently such technique becomes a very important subject for human life and to the college and universities, both the teaching, and researching programs. Viruses can be spread very fast, where the central air-condition systems probably take the ...


  • Controlling condensation- controlling mold

    You know those water stains on the ceiling tiles in your office that you are certain are caused by a leaky roof. Of course, the maintenance man thinks your crazy, since your office is not on the top floor. He dutifully changes the ceiling tile and a month later the water stain is back but this time it has those little black circles that look like mold colonies. Sound familiar? There seems to be ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you