air monitoring method Articles

  • Advanced monitoring method for air environment

    The Ogawa Passive Sampler is one of the only known methods of passive simultaneous monitoring of more than two components in the air. The first advantage of Ogawa Sampler is to have two chambers with the same configuration where one can place two different kinds of collection filter pads. In the case of simultaneous collection of NO and NO2, The  O2 collection filter foated with triethanolamine ...


    By Ogawa & Company, USA, Inc.

  • Ambient Air Sampling Methods

    Pollutants are nothing but any substance that may present in an atmosphere in such a concentration that it may harmful to surrounding, living organism or human being. Sampling and analysis of air pollutants is known as Air quality monitoring and it is major part of environmental monitoring. There are many advanced types of ambient air Sampling methods. we will learn here only which are most ...


    By Perfect Pollucon Services

  • Selecting the Right Air Quality Monitor

    There are many types of air quality monitors available, but which one is the best choice for measuring gaseous air pollutant concentrations? There are two classes of such air quality monitors: sampling monitors and in-situ monitors (“in-situ” = “in the original position”). Sampling monitors utilises a manifold through which the air to be analysed is pumped. A small air ...


    By Opsis AB

  • Lisbon air quality forecast using statistical methods

    Ozone and particulate matter levels in Southern European countries are particularly high, exceeding the established limit values, and the information and alert thresholds (in the case of ozone). Therefore, it is relevant to develop a good prediction methodology for the concentrations of these pollutants. Statistical models based on Multiple Regression (MR) analysis and classification and ...


    By Inderscience Publishers

  • Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas

    This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three ...


    By Ogawa & Company, USA, Inc.

  • Air quality modelling as a supplementary assessment method in the framework of the European Air Quality Directive

    According to the European Air Quality (AQ) Directive, member states must annually report their AQ to the European Commission (EC). This report can be based on modelling data if the concentration levels do not exceed the established lower assessment thresholds (LAT), or on combined data from modelling and monitoring systems (supplementary assessment methods) if concentrations levels are below the ...


    By Inderscience Publishers

  • Cartography for air quality monitoring: the geostatistical approach

    Being able to provide quick and accurate pollutant maps from readings at isolated measurement stations is becoming more important today in light of the European norms on air quality and the public’s demand to be informed. Commonly used algorithms for cartography are quick but their accuracy remains to be determined.Firstly, the choice of method is arbitrary and based on user’s subjective ...


    By Geovariances

  • The challenges and benefits of local air quality monitoring

    A new generation of air quality monitors is now being offered to provide localised, real-time air quality readings – but the potential benefit is only just starting to be realised. It is generally accepted that whilst measurements from air quality reference stations are highly accurate, they are not sufficiently location-specific. Key pollutants – such as NO2 and PM2.5 ...


    By AQMesh

  • Designing and Implementing Perimeter Air Monitoring Programs

    Perimeter or fenceline ambient air quality and meteorological monitoring programs have become increasingly valuable at hazardous waste, landfill, dredging, ports, and MGP remediation sites. Air quality monitoring programs protect public health and reduce owner liability ...


    By AECOM

  • A method for reducing purge volumes in deep monitoring wells: a purging experiment.

    Regulatory agencies often require three well casing volumes or more be purged prior to collection of groundwater samples for chemical analysis. Costs are high for testing and disposing of potentially hazardous purge water; therefore, efforts must be made to minimize waste-water volume while obtaining representative groundwater samples. Lockheed sponsored a purge experiment on two deep monitor ...


    By Hargis + Associates Inc

  • Lead Monitoring

    New lead standards are going to require new sampling methods. Fortunately, the latest samplers are making those requirements easier to cope with. Careful planning and research will produce valid, defensible results, while improvements in monitoring technology have increased the effectiveness and accuracy of modern high volume samplers. Today's samplers can save time and money, providing useful ...


    By American Ecotech LLC

  • Double benefit of monitoring Indoor Air Quality (IAQ)

    It is a difficult balance to save money and energy yet maintain a comfortable and healthy indoor air environment. A logical solution to controlling indoor air pollution is good ventilation coupled with IAQ monitoring using gas sensors. This can ensure healthy indoor air as well as a more efficient HVAC system.  Typical IAQ investigation and examination consists of taking single-point ...


    By PPM Technology

  • AQMesh: a new option for flexible air quality monitoring

    AQMesh has an impressive collection of global users and performance results measuring ambient air quality in applications ranging from traffic planning and urban hotspots to industrial fence line monitoring, building ventilation management, or environmental lobbying. This pole-mounted unit comes with an independent power supply and communications, so offering the possibility of measuring air ...


    By AQMesh

  • Rough set-based regionalisation in air quality monitoring

    Regionalisation is to organise a large set of spatial objects into spatially contiguous regions despite optimising the homogeneity of the derived regions, while representing social and economic geography. To confront this problem, it is necessary to classify the regions to form groups that are homogeneous in air quality attributes. It is to develop a system that applies data mining techniques to ...


    By Inderscience Publishers

  • Status of black carbon monitoring in ambient air in Europe

    Black carbon (BC) is increasingly discussed in science and environmental policy areas as an example of an air pollutant that affects both human health and contributes to climate change (e.g. WHO, 2012; UNEP/WMO, 2011; Bond et al., 2013; IPCC, 2013). In order to be able to make comparable measurements of BC in ambient air and to relate BC monitoring to health impacts and climate change it is ...

  • Air quality Monitors Track Pollution Hot-Spots

    Situated in the south west of Wales, in a largely rural area bordering the Brecon Beacons, Carmarthenshire’s air quality is predominantly good. However, there are areas of concern where major roads pass through some of the County’s larger towns, including Llanelli, Carmarthen and Llandeilo, where air quality is dominated by the effects of road traffic. The County Council is therefore ...


    By Air Monitors Ltd.

  • A method for mapping the air pollution in cities with the combined use of measured and calculated concentrations

    The aim of this paper is to develop the technique for mapping the air pollution in cities using measured and computed concentrations. It is based on the combined use of deterministic and stochastic modelling. Two different approaches are applied to extrapolate the measurements to the regular grid points covering the city. The first uses the method of the principal components, and the second is ...


    By Inderscience Publishers

  • Dust monitoring

    Generally, two different approaches are used to measure the amount of dust deposited on a surface; Determination of the soiling of a surface, by a change in its properties; Determination of the quantity of dust deposited, by weight. WHAT IS DUST? Dust is a generic term used to describe fine particles that are suspended in the atmosphere. Dust comes from a wide variety of sources, including soil, ...


    By Queensland Laboratory

  • A Method of Assessing Air Toxics Concentrations in Urban Areas Using Mobile Platform Measurements

    ABSTRACTThe objective of this paper is to demonstrate an approach to characterize the spatial variability in ambient air concentrations using mobile platform measurements. This approach may be useful for air toxics assessments in Environmental Justice applications, epidemiological studies, and environmental health risk assessments. In this study, we developed and applied a method to characterize ...

  • Monitoring of air pollution in Indian metropolitan cities: modelling and quality indexing

    Air quality in cities is the result of a complex interaction between natural and anthropogenic environmental conditions. Delhi, as well as many other cities in India, is facing problems concerning air pollution. The increase in industrialisation and the vehicle fleet, poor control on emissions and little use of catalytic converters, produce a great amount of particulate and toxic gases. Data on ...


    By Inderscience Publishers

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you