air sampling kit Articles

  • General Air Sampling Guidelines (PDF)

    This Standard Operating Procedure (SOP) provides guidance in developing and implementing sampling plans to assess the impact of hazardous waste sites on ambient air. It presents the United States Environmental Protection Agency/Environmental Response Team's (U.S. EPA/ERT's) approach to air sampling and monitoring and identifies equipment requirements. It is not within the scope of this SOP to ...

  • Detection of chlorpyrifos in air using low volume polyurethane foam (PUF) sampling with immunoassay

    MATRIX: Air samples ANALYTE: Chlorpyrifos RANGE OF DETECTION: 0.088 to 1.200 mg/m3 MATERIALS: Chlorpyrifos RaPID AssayÒ Kit and Sample Diluent. Reagents: methanol (pesticide grade). Equipment: 40 mL glass vials with Teflon lined caps, 13 x 100 mm glass test tubes, 5 mL and 20 mL serological pipets, micropipet ...


  • Casella intrinsically safe TUFF personal air sampling pump and dBadge sound level meter are a hit down under with Australian department of defence

    Following a competitive tender process, the Australian Department of Defence has taken delivery of 180 TUFF personal air sampling pumps and 180 CEL-350 dBadge personal noise dosimeters from Casella CEL (www.casellameasurement.com; 01234 844100), leading global specialist in industrial hygiene and occupational health monitoring equipment. Ronald Azar, ...


    By Casella

  • Expanding Reservoir Air Filters

    In all vented tanks, the rise and fall of fluid levels is offset by a corresponding volume of incoming and outgoing air. Keeping the incoming replacement air clean is essential for contamination control and thus the reliability of hydraulic systems. While targeting the system's reliability, JLM Systems Limited has developed the OilMiser™ Reservoir Aspirator (ORA) kit. This product represents a ...


    By JLM Systems Ltd

  • External exposure due to natural radioactivity in some household kits

    Specific activities (Bq/kg and ppm) of naturally occurring radionuclides were measured for about 57 samples from some household kits. The maximum specific activity values were 76.12, 118.37 and 3340.6 Bq/kg for U-238, Th-232 and K-40, respectively. The external exposure rate (μR/h) and dose rate (nG/h) were calculated. The maximum mean annual effective dose due to U-238 from Chinese ceramic ...


    By Inderscience Publishers

  • Detection of carbaryl in soil

    MATRIX: Soil ANALYTE: Carbaryl RANGE OF DETECTION: 40 to 500 ppb MATERIALS: SDI Carbaryl RaPID AssayÒ kit and Sample Diluent. SDI RaPID PrepÔ Soil Collection Kit (optional). SDI RaPID PrepÔ Extraction Kit: Type II (extraction solution, optional) Reagents: Methanol (pesticide grade), distilled or ...


  • Dewatering of moist sediments and soils for application to RaPID Prep AND RaPID assays procedures

    BACKGROUND INFORMATION: High moisture content (>30% by weight) can significantly lower concentrations of analytes detected in the RaPID Prep soil methods. In these methods, water associated with a sample will increase the volume of the extraction solution (liquid phase) and decrease the amount of soil (solid phase) in a weighed sample. In some cases, water may also decrease the ...


  • Detection of chlorpyrifos in soil

    MATRIX: Soil ANALYTES: Chlorpyrifos RANGE OF DETECTION: Chlorpyrifos: 10-500 ppb MATERIALS: Chlorpyrifos RaPID AssayÒ Kit and Sample Diluent. Methanol (pesticide grade). Sample Extraction Kit (call SDI for details0. SAMPLE PREPARATION: Allow frozen samples to thaw. Break up large ...


  • Detection of PCB on gauze wipes

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe, High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Kit and Sample Diluent. RaPID Prepä PCB Sample Extraction Kit. Reagents: hexane (pesticide grade). Equipment: 3 inch x 3 inch cotton gauze pads ...


  • Detection of parathion-methyl on gauze wipes

    MATRIX: Cotton gauze pad (wipe) ANALYTE: Parathion-methyl RANGE OF DETECTION: 0.08 mg per wipe (100 cm2) MATERIALS: EnviroGard Parathion Plate Kit (item #75000). SDI Wipe Extraction Kit. Protective gloves. WIPE PROCEDURE: Caution: Wear protective gloves for this procedure. Saturate a gauze ...


  • Detection of carbofuran in soil

    MATRIX: Soil ANALYTE: Carbofuran RANGE OF DETECTION: 10 to 500 ppb MATERIALS: Carbofuran RaPID AssayÒ kit and Sample Diluent. Reagents: methanol (pesticide grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) with ...


  • Detection of 2,4-D in soil

    MATRIX: Soil ANALYTES: 2,4-D RANGE OF DETECTION: 150 ppb to 7.5 ppm MATERIALS: 2,4-D RaPID AssayÒ Kit and Sample Diluent Reagents: methanol (pesticide grade), distilled or deionized water, glacial acetic acid. Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) ...


  • Detection of carbendazim in soil

    MATRIX: Soil ANALYTE: Carbendazim, a metabolite of benomyl RANGE OF DETECTION: 37.5 to 750 ppb MATERIALS: Benomyl/Carbendazim RaPID Assay kit and Sample Diluent Reagents: methanol (pesticide grade), sodium hydroxide (ACS grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles ...


  • Detection of atrazine, alachlor, cyanazine and metolachlor in soil

    MATRIX: Soil ANALYTES: Atrazine, Alachlor, Cyanazine, and Metolachlor RANGE OF DETECTION: Atrazine: 15-750 ppb Alachlor: 15-750 ppb Cyanazine: 15-450 ppb Metolachlor: 15-750 ppb MATERIALS: RaPID Assay Kit and Sample Diluent Reagents: methanol (pesticide grade), distilled or deionized water. ...


  • Detection of pentachlorophenol in wood

    MATRIX: Wood, reduced to fine shavings or sawdust ANALYTE: Pentachlorophenol (PCP) RANGE OF DETECTION: 1 to 100 ppm MATERIALS: Pentachlorophenol RaPID AssayÒ Kit and Sample Diluent Reagents: acetonitrile (pesticide grade). Equipment: reciprocating shaker, plastic bottles (polypropylene or high density ...


  • Hydrogen Sulfide Continuous Emission Monitoring of Odor Control Systems

    ABSTRACT This paper discusses the use of the Sycamore Continuous Emissions Monitor (CEM) for monitoring Hydrogen Sulfide Gas concentrations within odor control systems. The CEM is configurable as a single, two or three point system and can measure from 5 ppb to 2 PPM, 0.1 – 20 PPM, and 0 – 200 PPM and is designed for monitoring of scrubbers, carbon adsorbers, biofilters and biotrickling ...

  • Detection of pentachlorophenol in soil

    MATRIX: Soil ANALYTES: Pentachlorophenol (PCP) RANGE OF DETECTION: 100 ppb to 10 ppm MATERIALS: Pentachlorophenol RaPID AssayÒ kit and Sample Diluent Reagents: methanol (reagent grade), sodium hydroxide (ACS grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles (polypropylene or ...


  • An investigation and remediation of TNT contaminated soils.

    An investigation and remediation of TNT contaminated soils and wastes was conducted at the Apache Powder Superfund Site in Cochise County, Arizona during 1999 and 2000. TNT contamination was most likely the result of salvage operations of World War I munitions. Characterized by a steep hillside and arroyo cutting through the wastes, the site offered challenges of stability, access, health and ...


    By Hargis + Associates Inc

  • Drill King International is exploring reverse-circulation drilling opportunities in Chile

    The new XT RC50 hammer from Drill King International completed drilling trials at the beginning of August 2016. This 5in (127mm) reverse-circulation (RC) hammer is the first one from the XT (Extreme Torque) series, introduced by the down-the-hole (DTH) drilling equipment manufacturer from Texas, US. The XT RC hammer series will complement Drill King's extensive line of DTH air- and water-powered ...

  • Case study - GRO in soil at gasoline UST site

    These case studies show the performance using Sitelab’s UVF-3100 analyzer testing gasoline range organic hydrocarbons.  This includes benzene, xylene, BTEX and other volatile petroleum compounds in the GRO or VPH C6 to C10 hydrocarbon range. When calibrated using Sitelab's GRO calibration kit (CAL-025), the UVF analyzer produces test results that correlate well to laboratory ...


    By Sitelab Corporation

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you