air sampling unit Articles

  • Recent Develoments in Uranium Mining Air Sampling Programs in the United States

    Introduction and History Commercial uranium mining operations in the United States, beginning in the post World War II era, were primarily open pit mining. Open pit mining was the primary extraction method until in-situ recovery (ISR) began in the State of Wyoming in 1961. ISR is also known as in situ leaching (ISL), or solution mining. It is a mining process utilized to ...

  • Building Services Management - Air Sampling -

    Untitled Document Maintenance professionals are often the first responders to mold complaints in their facilities. building occupants can be exposed to fungal (mold) ...


    By EMSL Analytical, Inc.

  • General Air Sampling Guidelines (PDF)

    This Standard Operating Procedure (SOP) provides guidance in developing and implementing sampling plans to assess the impact of hazardous waste sites on ambient air. It presents the United States Environmental Protection Agency/Environmental Response Team's (U.S. EPA/ERT's) approach to air sampling and monitoring and identifies equipment requirements. It is not within the scope of this SOP to ...

  • A Dynamic Site Investigation: Adaptive Sampling and Analysis Program for Operable Unit 1 at Hanscom Air Force Base, Bedford, Massachusetts

     Abstract In this study, field analytical instrumentation and methods were used to support a risk assessment study at the airfield at Hanscom Air Force Base (HAFB, Bedford, Massachusetts). The site investigation is part of an ongoing effort to determine contaminant risk to ground water from soil. The field tools supported a dynamic workplan/adaptive sampling and analysis demonstration. Over ...

  • Analysis of Stack Emissions Using VOST Air Sampling Tubes and Capillary GC

    United States EPA SW-846, Method 0030, Volatile Organic Sampling Train (VOST), describes the sampling of emissions for volatile compounds from hazardous waste incinerator stacks. Supelco's VOST air sampling tubes are designed to fulfill the method requirements and provide low background levels.               ...


    By MilliporeSigma

  • Gas Analyser Unit

    Gas Analysers are used in several industries, chemical industries in particualr use gas analysers to monitor their gas emission levels, air quality samples are compared to high purity reference gases to analyse and measure the emissions.  A common practice is to “calibrate” the sample air against clean, dry pure reference gases such as H2, He, Ar, or N2. The ...


    By Fike UK

  • Bioremediation of fuel oil spill at a coastal naval air station in the united kingdom

    Introduction Approximately 1000 gallons of fuel oil had seeped from broken storage tank lines into the soil matrix beneath a boiler house. Oil was subsequently forced from beneath the boiler building by periodic heavy rainfall. The fuel oil migrated down a slope into a farmer"s field causing extensive damage to the vegetation and grazing area inhabited by sheep. ...


    By Microbac Ltd

  • Teledyne Scientific Instruments - Direct Sampling MS and MS/MS for Real Time Air Monitoring

    Presented at the 44th ASMS Conference on Mass Spectrometry, May 12-16, 1996 Portland, OR. Published in the Proceedings of the 44th ASMS Conference on Mass Spectrometry May 12-16, 1996 Portland, OR, in press. DIRECT SAMPLING MS AND MS/MS FOR REAL TIME AIR MONITORING C. Remigi, P.T. Palmer, Dept. of Chemistry & Biochemistry, SF State University, SF, CA ...


    By Environics, Inc.

  • United States Virgin Islands

    Our firm was privileged to perform an indoor air quality related abatement that also had a historical context. This involved an adverse exposure to the Governor of the USVI at the Governor's residence in Catharineberg, St. Thomas. We determined that Stachybotrys and other toxigenic fungi were present in the residence as a result of water leaks from the roof and indirect effects from air ...


    By Indoor Air Solutions, Inc

  • Setting the standards for headspace sampling by PID

    The responsiveness of PIDs to virtually all VOCs has seen them become the accepted tool for initial site entry assessment, ensuring optimal detection of unknown and often toxic or hazardous chemicals found at hazardous waste sites and chemical emergencies. The speed and accuracy of modern PID equipment means that many worker and community safety concerns during initial and ongoing operations can ...


    By Ion Science Ltd.

  • Innovations in Site Characterization. Case Study: Hanscom Air Force Base, Operable Unit 1 (Sites 1, 2, and 3)

     Executive Summary Field analytical instrumentation and methods were used to support a site characterization study at the Airfield at Hanscom Air Force Base (HAFB) Operable Unit 1. HAFB is located in Middlesex County, Massachusetts, and occupies land in the towns of Bedford, Concord, Lexington, and Lincoln. U.S. Air Force military operations began in 1941 and continued through 1973. With ...

  • Soil CO2 Flux Measurements -- Using the LI-8100 System to Collect Air Samples for Estimating Soil Trace Gas Flux

    Air samples can be collected from the same air stream used to measure soil CO2 flux with the LI-8100 Automated Soil CO2 Flux System, for estimating the flux of trace gas, such as methane (CH4), ammonia (NH3), nitrous oxide (N2O), isotopic species, etc. This application note describes a simple method for obtaining air samples from the LI- ...


    By LI-COR

  • Sustainable sampling of native bromeliads for environmental monitoring

    By analysing the leaves of bromeliads, the availability of chemical elements in the atmosphere can be assessed. However, sampling steps affect the reliability of using such plants for environmental quality studies. This paper describes a novel and sustainable sampling methodology for conservation units, in which small discs (6 mm diameter) of bromeliad leaves could be taken without removing ...


    By Inderscience Publishers

  • Casella intrinsically safe TUFF personal air sampling pump and dBadge sound level meter are a hit down under with Australian department of defence

    Following a competitive tender process, the Australian Department of Defence has taken delivery of 180 TUFF personal air sampling pumps and 180 CEL-350 dBadge personal noise dosimeters from Casella CEL (www.casellameasurement.com; 01234 844100), leading global specialist in industrial hygiene and occupational health monitoring equipment. Ronald Azar, ...


    By Casella

  • A Breath of Fresh Air for Your

    As the full effect of the Federal Clean Air Act (CAA) Amendments continue to impact today’s industry, many companies will be required to install new or additional air pollution control equipment.  With over two decades of proven success, catalytic oxidation is a popular method for controlling volatile organic compound (VOC) emissions.During the past 25 years, industry has made progress in ...


    By The CMM Group, LLC

  • Mcclellan air force base diffusion

    Parsons Engineering Science, Inc. (Parsons ES) was retained by the US Air Force Center for Environmental Excellence Technology Transfer Division (AFCEE/ERT) to perform an evaluation of passive groundwater diffusion sampling technology. The diffusion sampler evaluation was funded under Contract F11623-94-D0024, Delivery Order RL72, as part of the AFCEE/ERT Remedial Process Optimization (RPO) ...


    By EON Products Inc.

  • Expanding Reservoir Air Filters

    In all vented tanks, the rise and fall of fluid levels is offset by a corresponding volume of incoming and outgoing air. Keeping the incoming replacement air clean is essential for contamination control and thus the reliability of hydraulic systems. While targeting the system's reliability, JLM Systems Limited has developed the OilMiser™ Reservoir Aspirator (ORA) kit. This product represents a ...


    By JLM Systems Ltd

  • EISC success at United States Enrichment Corporation

    Client: United States Enrichment Corporation (USEC) in Paducah, Kentucky EISC’s Analytical Review and Reporting Suite (R & R Suite) lab data automation solution was provided to United States Enrichment Corporation (USEC) in Paducah, Kentucky. The R & R Software Systems automated the laboratory analytical process for Metals, General Chemistry, Semi-Volatiles, Volatiles, ...


    By EISC

  • The ‘ins and outs’ of air quality monitoring

    The National Institute for Health and Care Excellence (NICE) recently issued draft guidance on ‘Air pollution - outdoor air quality and health.’ In the following article Jim Mills, Managing Director of Air Monitors Ltd, explains why there will need to be more funding for monitoring if the mitigation measures mentioned in the guidance are to be implemented effectively. Jim also ...


    By Air Monitors Ltd.

  • Low-Flow (Minimal Drawdown) Ground-Water Sampling Procedures

    Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water ...


    By Solinst Canada Ltd.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you