ambient air gas meter Articles

  • Ambient Air Sampling Methods

    Pollutants are nothing but any substance that may present in an atmosphere in such a concentration that it may harmful to surrounding, living organism or human being. Sampling and analysis of air pollutants is known as Air quality monitoring and it is major part of environmental monitoring. There are many advanced types of ambient air Sampling methods. we will learn here only which are most ...


    By Perfect Pollucon Services

  • TDLAS Gas Detection Instrumentation

    PKL Technologies Inc. manufactures tunable diode laser (TDLAS) based gas detectors and monitors. Spectra-1 open path gas sensors are used in a variety of environmental and safety remote sensing applications. Spectra-1 gas sensors have been designed in a compact, easy to use, robust and portable format. Spectra-1 has been developed using proprietary hardware and software, to produce a low cost ...


    By PKL Technologies Inc.

  • A Review of 1-Hour NO2 NAAQS Air Quality Modeling

    During the development of this 4TR article, proposed revisions to Appendix W to 40 CFR Part 51 – Guideline on Air Quality Models (Guideline) were published in the Federal Register. As a result of revisions which propose to establish Tier 3 nitrogen dioxide (NO2) atmospheric chemical reaction screening techniques as default methods, ...


    By All4 Inc.

  • Continuous monitoring of BTEX and PAH using automatic thermal desorption-gas chromatography

    Polycyclic Aromatic Hydrocarbons (PAHs) are a group of over 100 different chemicals that are known to be formed typically during incomplete combustion of organic matter at high temperature. Their major sources in the atmosphere include industrial processes, vehicle exhausts, waste incinerations, and domestic heating emissions. Due to their carcinogenic/mutagenic effects, 16 PAHs are currently ...


    By Chromatotec Group

  • Continuous Monitoring of BTEX and PAH using Automatic Thermal Desorption-Gas Chromatography

    Polycyclic Aromatic Hydrocarbons (PAHs) are a group of over 100 different chemicals that are known to be formed typically during incomplete combustion of organic matter at high temperature. Their major sources in the atmosphere include industrial processes, vehicle exhausts, waste incinerations, and domestic heating emissions. Due to their carcinogenic/mutagenic effects, 16 PAHs are currently ...


    By Chromatotec Group

  • What`s the Best Air Pollution Control Technology for My Process?

    Air pollution control equipment is not something that business owners address by saying, “Let’s do the right thing for the environment and install an oxidizer!” In fact, the scenario is more likely to be “We need to increase productivity (always a good thing!), but that will put us over our annual emissions limits. Do we know what we will need? Where do we start? Who can ...

  • Case study - N°AA4 – Ambiant air monitoring – WWP TRS MEDOR Stripping

    Context & Challenges Globally, the wastewater treatment is the first public health issue. Urban development leads to urbanization near waste water treatment plant and extension of sewerage network. These aspects induce to an augmentation of sulfur compounds (H2S, mercaptans and sulfides) which are very corrosive, odorant and toxic. To monitor this compounds online CHROMATOTEC® ...


    By Chromatotec Group

  • A Comparison of Point Sensors and Open Path Monitors For Toxic Gas (esp. HF) Monitoring

    Point Sensors Ion Mobility Spectroscope (IMS) – a gas sample is ionized by a radioactive source (Ni63). Differences in ion drift under the influence of an applied electric field produce a spectrum that is dependent on the mass, charge, and shape of the component ions. The detector signal and strength is tuned to the drift time of the ion of interest (in this case HF) and signal strength is ...


    By Boreal Laser Inc.

  • Safety Systems Depend on Reliable Field Sensors (Emphasis on Fire and Gas Detectors)

    Abstract Because not all hazards are the same, identifying and quantifying the hazard is the starting point in choosing sensing technology. Not all detectors are the same, and they should be selected according to their ability to detect the hazard. This paper gives a broad summary of technologies that provide users reliable responses to hazardous conditions, that minimise false ...

  • Canarina DISPER software · Safety engineering · commands 22

    The necessary data is: Physical stack height (m): This is the physical stack height in meters. Stack gas exit velocity vs (m/s): This is the stack gas exit velocity. It can be around 15 m/s. Stack ...

  • EPA studies identify techniques for critical leak testing prior to soil-vapor sampling

    Researchers at EPA’s National Risk Management Research Laboratory (NRMRL) in Ada, OK, are developing quality assurance (QA) measures for soil-gas and sub-slab sampling methods that help differentiate contaminant vapors due to vapor intrusion from background sources. Recent research focused on measures to identify leakage of ambient air into conventional vapor probes, which can significantly ...

  • Continuous measurement of Process oxygen for Claus sulfur recovery unit (sru) start-ups and shut-downs case study

    During start-up and shut-down, any time a sulfur recovery unit (SRU) transitions from ambient temperature through fuel gas warm up to the introduction of acid gas, measurement of 02 stoichiometry is critical. Historically, operators have manually taken samples using a portable electrochemical type Os analyzer. While giving more or less satisfactory results, the requirement for more stringent ...

  • Nitrogen Demand Increases for Semiconductor: How Safe Are You?

    As users demand ever-smaller smartphones and better televisions, semiconductor manufacturing plants are tasked with developing new products faster and using new materials. Key to the continued success of the semiconductor industry are inert gases, which include nitrogen and argon. When used safely, both nitrogen and argon play a number of important roles within the semiconductor ...

  • Who Needs Continuous Emissions Monitoring?

    Continuous emissions monitoring (CEM) is about monitoring air pollutants generated by a specific activity and emitted to the ambient air, typically through a tall stack or other exhaust pipe. The “activity” can be some industrial process like a power plant or a waste incinerator, but it can also be on a much smaller scale such as a car equipped with an internal-combustion engine. ...


    By Opsis AB

  • How to Save with Cooling Tower Credits

    Cooling towers dissipate heat from recirculating water used to cool chillers, air conditioners, or other process equipment to the ambient air. Heat is rejected to the environment from cooling towers through the process of evaporation. Therefore, by design, cooling towers use significant amounts of water. The thermal efficiency and longevity of the cooling tower and equipment depend on the proper ...


    By WaterSignal

  • Japanese Organics Recycling Association Formed

    Another backyard composting adage states that compost should have the feel of a wrung-out sponge — damp but not dripping wet. Actually, a wrung-out sponge may be on the dry side for composting, but the analogy does provide a great image for understanding the reasons for balancing moisture. Like a compost pile (or windrow or material in a vessel), a sponge is a solid mass containing an enormous ...


    By BioCycle Magazine

  • Flying High

    Operating a biogas plant without gas quality and flow instrumentation is like trying to fly a ...


    By Gas Data Ltd

  • Compost Data Tracking And Analysis

    From tip fee invoice tracking to process control to compost product sampling, information gathering, analysis and reporting are key to successful facility operations.   COMPOSTING is a highly regulated component ...


    By BioCycle Magazine

  • Ask Enhesa Vol. 6

    Featuring contributions from Gabriela Troncoso, Katsiaryna Anoshka, Elise Saade, Kengo Okuda, Paige Samson, Caitlin O’Sullivan, Ruth White and Wassila Nabourema and Tjeerd Hendel-Blackford ...

  • Making wet waste destruction a sustainable reality

    Irish environmental company SCFI was supported by the European Union’s Eco-Innovation initiative in a project to build a portable unit to demonstrate its innovative AquaCritox wet waste treatment technology. This White Paper describes the science behind hydrothermal oxidation (HTO) as a waste treatment methodology and its potential across a range of industrial applications, which is now, ...


    By SCFI Group Limited

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you