ambient analyser Articles

  • Solid waste management in Patna – analyses of ambient air and ground water pollution

    Municipal Solid Waste (MSW) in Patna is disposed of in an unscientific manner without considering environmental impacts. The wastes are dumped in the low-lying areas without compliance of the MSWM Rules, 2000. The dumped wastes are mixed with biomedical wastes making it hazardous. Ambient air quality and ground water were analysed at two dump sites to study the possible impacts of MSW. The ...


    By Inderscience Publishers

  • Why measuring the ambient NO2 without conversion?

    Nitrogen oxides NOx are pollutants that may have particular impact in terms of greenhouse gases, acidifying air etc ... issuance increased significantly since 1950 with the massive development of transport and industries. It therefore becomes necessary to provide measures always safer these pollutant gases, and to know the reliability of results. Currently, 60% of emissions of NO and NO2 are ...


    By ENVEA

  • Energy and exergy analyses of a supercritical power plant

    Energy and exergy efficiencies of a supercritical power plant have been studied in this paper. The effect of ambient weather condition was considered on the condenser pressure. It was shown that high ambient temperature has more adverse effect on the exergy efficiency than the energy efficiency. As ambient temperature increases, the exergy efficiency of the boiler, condenser, heaters and feed ...


    By Inderscience Publishers

  • How Does a Gas Analyser Work?

    Whatever you want to detect, you need to identify a property of the object that is easy-enough to measure. When it comes to monitoring and analysis of gaseous species (atoms or more commonly molecules), it turns out that it often is possible to utilize the optical properties of the gas. You need a light source, a light detector, and a characteristic behaviour of the gaseous species in question ...


    By Opsis AB

  • Ambient Air Fence Line Application case study

    Customer: Confidential Application: Ambient air Fenceline application Background: The Victoria Environmental Protection Agency installed an Opsis DOAS open path system to measure Benzene & ...


    By Ecotech Pty Ltd

  • Status of black carbon monitoring in ambient air in Europe

    Black carbon (BC) is increasingly discussed in science and environmental policy areas as an example of an air pollutant that affects both human health and contributes to climate change (e.g. WHO, 2012; UNEP/WMO, 2011; Bond et al., 2013; IPCC, 2013). In order to be able to make comparable measurements of BC in ambient air and to relate BC monitoring to health impacts and climate change it is ...

  • Understanding ambient air quality instrument operating ranges

    In order to maximize the performance of an air quality monitoring station, careful selection of instrumentations is essential. One of the key issues is to have a good understanding of what pollutants need to be measured and at what concentrations. There are several different types of air quality monitoring, these include: Trace/Background Monitoring This is performed in areas where ...


    By Ecotech Pty Ltd

  • Surface roughness vision measurement in different ambient light conditions

    Machine vision method was used to measure the surface roughness for different Φ38 mm grinding axes in different ambient light conditions. To analyse the effect of ambient light, a method based on the grey-level co-occurrence matrix was applied at the first step. Then, a new calculation method was proposed to minimise the effect of ambient light during measurement. At the calibration stage, ...


    By Inderscience Publishers

  • An ambient air quality monitoring network for Buenos Aires city

    This paper proposes an objective methodology for designing a multi-pollutant urban air-quality monitoring network to detect concentrations greater than reference concentration levels (CL). The network design includes both air quality simulation and an objective analysis based on monitoring tasks. The proposed methodology is applied to the city of Buenos Aires. Pollutants of concern are nitrogen ...


    By Inderscience Publishers

  • Case study - Ambient air monitoring by PID detection - airTOXIC

    First Case THE PROBLEM: How to monitor air quality from 1 spot in 12 different towns ? THE SOLUTION The airToxic PID with the communication protocol MODBUS allows to transfer the results of the 12 instruments to a central room RESULTS airToxic PID allows to have an improved ...


    By Chromatotec Group

  • FTIR resolution requirements for industrial gas analyses

    FTIR Spectroscopy FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epitreatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D faciltities, FTIR is applied to combustion ...


    By CIC Photonics

  • Short-term variations in ambient particulates and their sources in Taichung, Taiwan

    Ambient particulate measurements were carried out using TE-PUF sampling and a Universal Air Sampler between 8 March and 25 April 2001 at Taichung. Samples were collected every 6 hours beginning at 0100 LST (Local Standard Time) each day at two sites, one at a university campus and the other at a roadside. Chemical species (Cl-, NO3-, ...


    By Inderscience Publishers

  • Gas analysers support management of Swindon fire

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents. Arrangements have been made in England to bring together experts from the Environment Agency ...


    By Quantitech Ltd

  • Gas Chromatography: MCERTS Certification for Ambient Air Analysis on Benzene and VOCs

    Due to environmental issues, the world of gas analysis is evolving very rapidly. Governments set the rules to limit and control the environmental pollution through legislation. Volatile organic compounds (VOCs), often produced by human activities, are amongst the sources of pollution that need to be identified and quantified for safety reasons. Exposure to high concentrations of certain VOCs is ...


    By Chromatotec Group

  • Experiences in the modelling of traffic policy measures for ambient air quality management in Lithuania

    This paper presents the application of the Integrated Transport Effect Modelling System (ITEMS) in the city of Kaunas, Lithuania, taking into consideration some factors such as existing vehicle fleet, traffic flows, and ambient air quality monitoring data. The objective of this study is to estimate the exhausts of CO, NOx, and SO2 released by motor vehicles in relation to predictive traffic ...


    By Inderscience Publishers

  • New Nitrogen Dioxide Ambient Air Quality Standard Could Pose Challenges

    In the more than 200 air quality modeling analyses that ALL4 meteorologists have conducted, demonstrating compliance with the annual nitrogen dioxide (NO2) National Ambient Air Quality Standard (NAAQS) of 53 parts per billion (ppbv) has rarely been an issue.  The relative ease for demonstrating compliance with the annual NO2 NAAQS is due to two (2) factors.  First, the ...


    By All4 Inc.

  • Case study : VOC analysis in ambient air by FID dectection - Complete system airmOzone

    Ozone concentration has been multiplied by 5 in the last century in the middle latitudes of the northern hemisphere from 10 PPB in 1874 to approximately 50 PPB today. This is an increase of 1.6% per year; the trend is probably higher (2.4% a year) over the last decades. (Chapter 1 of the International Geosphere-Biosphere Program - World Climate Research Program) In order to stop this global ...


    By Chromatotec Group

  • FTIR analyser improves anaesthetic gas detection at Torbay Hospital

    A unique gas measurement technology has enabled South Devon Healthcare’s Pharmacy Manufacturing Unit (PMU) at Torbay Hospital to conduct highly effective and detailed analysis of anaesthetic gases in a variety of hospital locations. The primary function of the PMU’s quality control department is to check active ingredient levels and sterility in manufactured pharmaceutical ...


    By Gasmet Technologies Oy

  • A positive association between cryptosporidiosis notifications and ambient temperature, Victoria, Australia, 2001–2009

    Increased temperatures provide optimal conditions for pathogen survival, virulence and replication as well as increased opportunities for human–pathogen interaction. This paper examined the relationship between notifications of cryptosporidiosis and temperature in metropolitan and rural areas of Victoria, Australia between 2001 and 2009. A negative binomial regression model was used to analyse ...


    By IWA Publishing

  • Weekday/Weekend Differences in Ambient Air Pollutant Concentrations in Atlanta and the Southeastern United States

    Abstract The authors quantified changes between mean weekday and weekend ambient concentrations of ozone (O3) precursors (volatile organic compounds [VOC], carbon monoxide [CO], nitric oxide, and oxides of nitrogen [NOx]) in Atlanta and surrounding areas to observe how weekend precursor emission levels influenced ambient O3 levels. The authors analyzed CO, nitric oxide (NO), and NOx ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you