ambient gas sampling Articles

  • Ambient Air Sampling Methods

    Pollutants are nothing but any substance that may present in an atmosphere in such a concentration that it may harmful to surrounding, living organism or human being. Sampling and analysis of air pollutants is known as Air quality monitoring and it is major part of environmental monitoring. There are many advanced types of ambient air Sampling methods. we will learn here only which are most ...


    By Perfect Pollucon Services

  • Evaluating Leaks in a Soil Gas Sampling Train

    ABSTRACT The current advisory for active soil gas investigations in California requires leak tests to be conducted at eveiy soil gas probe while taking a sample. A leak may allow ambient ak into the sample train thus diluting the soil gas and underestimating the results. Also, the leak check compound itself may have impurities thereby contaminating the sample. The advisoiy suggests leak ...


    By Eurofins Air Toxics Inc

  • Why measuring the ambient NO2 without conversion?

    Nitrogen oxides NOx are pollutants that may have particular impact in terms of greenhouse gases, acidifying air etc ... issuance increased significantly since 1950 with the massive development of transport and industries. It therefore becomes necessary to provide measures always safer these pollutant gases, and to know the reliability of results. Currently, 60% of emissions of NO and NO2 are ...


    By Environnement S.A

  • Area Monitoring: Diffusion Sampling

    Indoor and outdoor gas hazards that exist in open areas are usually monitored using diffusion-type sensors. A diffusion sensor has no active sample-drawing system; diffusion sensors rely on the ambient air movement and pressure to deliver the sample to the sensing element. Diffusion-type sensors are a reliable and cost-effective way to monitor open area gas hazards. When installing diffusion ...

  • Vertical and Diurnal characterization of volatile organic compounds in ambient air in Urban areas

    More than half of the world’s population lives in cities, and their populations are rapidly increasing. Information on vertical and diurnal characterizations of volatile organic compounds (VOCs) in urban areas with heavy ambient air pollution can help further understand the impact of ambient VOCs on the local urban environment. This study characterized vertical and diurnal variations in ...

  • Field demonstration of a near-real-time multi-metals ambient fence line monitor case study

    National emissions standards for hazardous air pollutants (HAPs) are required under Section 112 of the Clean Air Act to limit the release of specified HAPs. Permitting, monitoring and enforcement of these emission limits are an integral part of managing air quality to protect human health and the environment. However, this is difficult and highly uncertain in the case of fugitive emissions ...


    By Cooper Environmental

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Low-Flow (Minimal Drawdown) Ground-Water Sampling Procedures

    Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water ...


    By Solinst Canada Ltd.

  • Advanced gas detection technology supports arctic greenhouse gas research

    Enormous quantities of greenhouse gases (GHG) exist within Arctic ice and frozen soils, so with the threat of global warming, a clear understanding of the relationship between GHG in the atmosphere and in the ice/soil is vital because melting of permafrost could cause a dangerous climate tipping point. There can be few more challenging environments for monitoring gases, but PhD researcher Martin ...


    By Quantitech Ltd

  • Advanced Gas Detection Technology supports Arctic Greenhouse Gas Research

    Enormous quantities of greenhouse gases (GHG) exist within Arctic ice and frozen soils, so with the threat of global warming, a clear understanding of the relationship between GHG in the atmosphere and in the ice/soil is vital because melting of permafrost could cause a dangerous climate tipping point. There can be few more challenging environments for monitoring gases, but PhD researcher Martin ...


    By Gasmet Technologies Oy

  • Gas detector communication technology for offshore oil and gas platforms

    In few applications is safety as important as on offshore oil and gas platforms. Explosive hazards from hydrocarbon gases and vapours are an ever-present risk, whilst toxic hydrogen sulphide gas and depleted oxygen environments can pose significant risks to personnel. Gas detectors are therefore essential to provide dependable early warning of gas hazards. Gas detectors are permanently installed ...

  • EPA studies identify techniques for critical leak testing prior to soil-vapor sampling

    Researchers at EPA’s National Risk Management Research Laboratory (NRMRL) in Ada, OK, are developing quality assurance (QA) measures for soil-gas and sub-slab sampling methods that help differentiate contaminant vapors due to vapor intrusion from background sources. Recent research focused on measures to identify leakage of ambient air into conventional vapor probes, which can significantly ...

  • New gas calibration method eases TOC analysis

    LAR Process Analysers AG of Berlin,  Germany expanded the range of feaiures of its measuring device QuickTOC, which facilitates the monitoring of ultra pure and cooling water, boiler feed and condensate measurement, and industrial wastewaters. For many years, the Berlin company lias been developing, high quality measuring devices and processes for the TOC analysis of condensates and boiler ...


    By LAR Process Analysers AG

  • A Guide to Gas Detector Tubes. Your Questions Answered

    Gas detector tubes are easy to use, are low cost, and the method is intrinsically safe, allowing it to be deployed in all industries. Because detector tubes don’t require calibration, users see the benefits of this technology over electronic gas detectors due to their ease of ...


    By a1-cbiss

  • Canopy gas exchange measurements of cotton in an open system

    A portable, open transparent chamber system for measuring canopy gas exchanges was developed and tested. Differentials between incoming and outgoing atmospheric H2O and CO2 concentrations were used to calculate canopy transpiration (E) and net assimilation (A) at 10-s intervals using solenoid valve actuated sample lines connected to an infrared gas analyzer. A programmable data logger controlled ...

  • Gas Monitoring for Ventilation Control and Energy Management

    The growing demand for underground and enclosed parking and maintenance garages (resulting from limitations on land availability) has increased the awareness and need for proper ventilation and control systems. In addition, increased health and safety programs have only added to the concerns of toxic and combustible gases in confined or enclosed spaces. Historically, ventilation and make-up air ...


    By Arjay Engineering Ltd.

  • Environics - Reducing calibration gas cost by up to 60%

    EPA's appendix 'M' 40 CFR 51 reduces calibration gas cost by 60%By: Terrence P. Dunn, President of EnvironicsOn May 30, 1995, the EPA published the final version of Method 205 for inclusion in Appendix M of 40 CFR Part 51 entitled, 'Verification of Gas Dilution Systems for Field Instrument Calibrations.' Continuous emissions monitoring systems (CEMS) require ...


    By Environics, Inc.

  • Gas analysers support management of Swindon fire

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents. Arrangements have been made in England to bring together experts from the Environment Agency ...


    By Quantitech Ltd

  • Improved HF monitoring in Primary Aluminium Smelters with Laser Gas Detectors

    Primary aluminium smelting generates large amounts of hydrogen fluoride gas (HF). Concerns for worker safety and ambient air quality require that HF be monitored at several locations in smelters. Historically, a variety of methods have been used for HF monitoring. Cassette samplers and wet chemistry techniques, coupled with complex and expensive ...


    By Boreal Laser Inc.

  • FTIR gas analyzers support management of fire at UK waste facility

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents.  Arrangements have been made in England to bring together experts from the Environment ...


    By Gasmet Technologies Oy

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you