analytical test kit Articles

  • Detection of PCB in water using the ensys test kit

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: 1260: 50 ppb 1254: 50 ppb 1248: 100 ppb 1242: 200 ppb 1232: 400 ppb 1016: 400 ppb MATERIALS: Ensys PCB 12 Test Kit, item # 7020301. Ensys PCB Soil Extraction Kit #7020300EA. Clean tap or deionized water. Equipment: Ensys Field System ...


  • Detection of 2,4-D in pears using the rapidassay test kit

    MATRIX: Pears ANALYTE: 2,4-D LIMIT OF DETECTION: 10 ppb MATERIALS: RapidAssay 2,4-D test kits. RapidAssay 2,4-D sample diluent. Food Prep Test Kit (part number A00149). Acetone (not provided). NOTES: Because pears contain a substance that could potentially interfere with the immunoassay, ...


  • Testing of numerical advection schemes and splitting techniques used in pollution dispersion modelling on an analytic solution

    In the real nature the processes of pollutants advection, their release in and removal from the atmosphere take place simultaneously. In dispersion modelling, these processes are considered separately, one after another within a time step, which causes the generation of some specific errors. Two types of numerical advection schemes, typical Eulerian and semi-Lagrangian one, are considered. The ...


    By Inderscience Publishers

  • When Consumables Kits are Greater Than the Sum of their Parts

    ProteinWorks and GlycoWorks kits address more than sample prep challenges One of the most challenging parts of an LC-MS workflow happens before analytical chemists even turn to their instrument: Sample preparation. Get it right, and the analytical run performs as expected. Get it wrong, and the assay has any number of problems, from poor sensitivity to poor reproducibility. The ...


    By Waters Corporation

  • Interpretation of total petroleum hydrocarbon (TPH) results with RaPID assay kits

    SUMMARY The SDI RaPID Assays for petroleum hydrocarbon fuels (Total BTEX, PAHs) have been shown to provide excellent correlation with GC based (8015M) and IR based (418.1) methodologies for testing Total Petroleum Hydrocarbons (TPH). Linear relationships between immunoassay and TPH results with both gasoline and diesel fuels are demonstrated. Fuel reactivities with immunoassay are shown to ...


  • Preparation of <25x or >100x dilutions with the rapid prep universal range extension kit

    GENERAL COMMENTS: This procedure describes how to prepare dilutions of less than 25x or greater than 100x using the appropriate RaPID AssaysÒ Sample Diluent and components of the RaPID PrepÔ Universal Range Extension Kit. Preparing dilutions of 25x to 100x are already described in the package insert of the Universal Range Extension Kit. Serial dilutions using components of the ...


  • Analysis of PCB in water using the envirogard test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Aroclor 1248: 1 ppm Aroclor 1260: 2 ppm Aroclor 1242: 2 ppm Aroclor 1254: 1.1 ppm BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A chemical reaction is induced that causes a color change ...


  • Analysis of PCB in water using the Dtech test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Color Card: 100 ppb (as aroclor 1254), DTECHTOR meter: 50 ppb (as aroclor 1254) BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A 1:2 dilution of the sample in methanol is made to minimize adsorptive losses. A ...


  • Detection of PAH IN WATER using the ensys test system

    MATRIX: Water ANALYTES: PAH LIMIT OF DETECTION: 15 ppb MATERIALS: Ensys PAH Risc Soil Test Kit. Methanol (ACS Reagent Grade). Deionized water. Equipment: Ensys Field Accessory System. SAMPLE PREPARATION/ANALYSIS: Follow procedures are outlined in the Ensys PAH Risc Test Kit User’s ...


  • High range chlorine testing – what are the options?

    Higher range chlorine solutions are typically used for disinfecting products but standard chlorine meters often cannot measure to higher ranges. For example the Hach Pocket Colorimeter II for chlorine measures to a maximum of 2mg/L, and the ...


    By Camlab Limited

  • Analysis of TNT AND RDX on gauze wipes using the dtech test system

    MATRIX: Gauze Wipe ANALYTE: TNT and RDX LIMIT OF DETECTION: TNT: 2.25 ug/100 cm2, RDX: 2.25 ug/100 cm2 BACKGROUND: This application describes a field screening method for determining TNT or RDX concentrations on gauze wipes. Acetone is used to extract the TNT or RDX from the gauze wipe and a chemical reaction is ...


  • Detection of PCB on gauze wipes using the rapid assay test system

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe. High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Test Kit (A00133) and Sample Diluent (A00136). PCB Wipe Sample Extraction Kit (A00137WA). Reagents: Methanol (ACS Reagent grade). Equipment: 3 inch x 3 ...


  • Detection of polychlorinated biphenyls (PCBs) in concrete using the dtech test system

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: DTECHTOR: 500 ppb to 25 ppm (as aroclor 1254). Color Card: 1 ppm to 25 ppm (as aroclor 1254) MATERIALS: DTECH PCB Test Kit. DTECH PCB Sample Extraction Kit. Reagents: table salt (sodium chloride) or salt packets used by restaurants ...


  • Use of PAHs RaPID ASSAY kits for semi-quantitative screening consistent with SW-846 Methood 4035

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Use of SDI carcinogenic PAHs RaPID assay kits for semi-quantitative screening consistent with SW-846 method 4035

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Use of SDI total btex/tph rapid assay kits for semi-quantitative screening consistent with sw-846 method 4030

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Detection of polychlorinated biphenyls (PCBs) in concrete using the ensys test system

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: Aroclor 1254: 0.5 ppm Aroclor 1260: 0.5 ppm Aroclor 1248: 1.0 ppm Aroclor 1242: 2.0 ppm Aroclor 1232: 4.0 ppm Aroclor 1016: 4.0 ppm MATERIALS: Ensys PCB in Soil Test Kit. Ensys PCB Sample Extraction Kit. Reagents: table salt ...


  • Use of TNT RaPID ASSAY kits for semi-quantitative screening consistent with SW-846 method 4050

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Use of SDI 2,4-d rapid assay kits for semi-quantitative screening consistent with SW-846 METHOD 4015

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators and reports results in semi-quantitative ranges lying above, below or ...


  • Use of SDI pentachlorophenol rapid assay kits for semi-quantitative screening consistent with sw-846 method 4010

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators and reports results in semi-quantitative ranges lying above, below or ...