automatic meter reading meter Articles

  • Consumption estimation with a partial automatic meter reading deployment

    Automatic water meter reading (AMR) is now the best kind of technology to supply real time information on water consumption. Complete equipment of a district metered area enables the assessment of the total consumption of a finite size population, for a time scale sometimes as short as an hour. However, its cost for generalization can generate high capital expenditures (CAPEX), unaffordable for ...


    By IWA Publishing

  • How to Use Manual Energy Data Readings (New App)

    Today we introduce a new app that will make it easier for you to import data to your energy analytics platform or correct mistakes on readings. Say hi to the Manual Readings App. Manual Reading is Not a Best Practice, ...


    By DEXMA

  • Radiation Monitors and Meters

    Light Description and Applications The light meter is a portable unit designed to measure visible, UV, and near-UV light in the workplace. (The CTC has a UV light meter available through its loan program, ALEP.) The light meter is capable of reading any optical unit of energy or power level if the appropriate detector has been calibrated with the meter. The spectral range of the instrument is ...

  • The key advantages of FlashRES resistivity meter

    FlashRES-UNIVERSAL is the first instrument in the world that can fully utilise all its electrodes during data collection.  It is a significant technological breakthrough. FlashRES-UNIVERSAL has following key advantages: FlashRES is a 61-channal resistivity/IP system and it is extremely fast For each current injection, conventional resistivity systems usually collect ...

  • Electronic Water Meter For Leakage Repair - Case Study

    Every year, EMS (Energy Management System) produces and markets smart electronic water meters (domestic/ bulk), wireless transmission data logger (GSM/ GPRS), and advanced AMR (Automatic Metering Reading) systems. Unlike traditional mechanical water meter, the magnet-free electronic smart water meter with class C (CNS 14866) metrological performance can maintain 12 years battery lifespan. With a ...

  • Soil CO2 Flux Measurements -- Addressing Spatial Variability: Determining the Number of Readings Required

    Soils can be highly variable in terms of CO2 flux values. Even at a seemingly uniform site, the soil CO2 flux might range from 2 μmol/m2/s at one location to over 4 mol/m2/s just a few meters away. To obtain reliable site mean flux values, it is important to determine how many readings might be required so that time and resources can be properly allocated before starting an investigation. In ...


    By LI-COR

  • Wastewater Plant Relies on Thermal Flow Meter for Co-Gen Power Gas Blending Process

    The Rahway Valley Sewerage Authority (RVSA), which operates a large wastewater treatment plant in New Jersey, embarked on a green co-generation waste-to-energy project to power a portion of its operations. The plant performs primary, secondary, tertiary and sludge treatment processes in serving over 250,000 residential customers and 3000 industrial and commercial customers in a 40-plus square ...


    By Modern Pumping Today

  • Detecting leaks through AMR data analysis

    Automatic meter reading (AMR) provides real-time consumption data, enabling to collect a huge amount of information about daily, even hourly, consumptions. It is then easy to assess lost volumes on the network, using supplied volumes information. However, because of the multiple components of water losses, the metering and calculation inaccuracies, the occurrence of new (detectable) leaks is ...


    By IWA Publishing

  • City of Groningen – going for sustainable

    The city of Groningen, counting over 180,000 inhabitants is the largest city of the northern provinces of the Netherlands. The city is known for its lovely architecture, its vibrant nightlife and many cultural destinations. And lately the city wants to be known as well for its ambition to become Holland’s most sustainable city. Energy saving is the most effective way to obtain ...


    By eSight Energy

  • What You Need to Know about Electronic Automation of Hydraulically-operated, Diaphragm-actuated Control Valves

    Hydraulically controlled, diaphragm-actuated control valves are the mainstay of the waterworks industry to control pressure, flow, level, pump control, and at times to meter. These automatic control valves are controlled by pilots to do specific tasks and are mainly single-set-point systems. With the need to remotely actuate and control the valves and the applications becoming more complex, ...


    By IWA Publishing

  • Decision support system for main pumping station control, BOS Delfland

    The waterboard Delfland uses a DSS to automatically control the 7 pumping stations in its main canal system. Delfland manages a small part of the dutch watersystem in the south-west of the country. The area is mostly below sealevel and it is intensively used, for residential areas, greenhouses and industry. It is only 400 km/2, yet houses 1,6 million inhabitants, multiple cities among which the ...


    By IWA Publishing

  • What are the key steps in measuring pH? Why do I need to calibrate?

    pH is a useful parameter which is used across all industries for quality control, environmental monitoring, lab work and much more. There are 10 key steps which should be followed to ensure pH measurements using a meter are accurate. pH is a useful parameter which is used across all industries for quality control, environmental monitoring, lab work and much ...


    By Camlab Limited

  • Stormwater Solids Reduction for NPDES Permits

    Finally obtaining a National Pollution Discharge Elimination System (NPDES) Permit is often a relief but is by far not the end of the story. Meeting the requirements of that permit often proves to be quite difficult and stiff fines are freely doled out to those who fail to meet regulatory limits. For one Midwest jet propulsion manufacturing facility, the issue of total daily solids discharge ...

  • Optimizing Metals Removal

    Optimizing Wastewater Metals Removal Making Wastewater Metals Insoluble for Easy Removal To remove metals from wastewater, the metals need to be insoluble (not in solution). Many facilities, such as in the ...


    By Integrated Engineers Inc.

  • Legoland Windsor chooses eSight to monitor energy consumption across site

    LEGOLAND Windsor is part of the Merlin Entertainments Group. Opened in 1996, the park extends over 150 acres and is one of four LEGOLAND parks in the world. LEGOLAND Windsor contains over 50 interactive rides, shows and attractions, 11 restaurants and cafes and 7 shops The Requirement The requirement was for the supply of both hardware and software for the LEGOLAND theme park ...


    By eSight Energy

  • How to monitor your energy consumption effectively

    An increased need to act on energy management issues has put a priority on aM&T systems for any company wanting to monitor their energy use effectively. Rising energy costs and the current economic crisis have put an increased focus on controlling costs, providing more reasons than ever to act on energy management issues. Industrial and commercial organisations are seen themselves ...


    By Vital Efficienci Ltd.

  • Radio Solution brings real-time monitoring benefits for water supplier

    Introduction of wireless data collection and analysis improves leak detection and water supply efficiency Companies whose business is the delivery of water to consumers, do not only have a responsibility to provide high quality drinking water to both domestic and industrial users, but also to ensure that it is done so economically and reliably. The WLV association ...

  • Noise 101: What is Equivalent Continuous Sound Level (Leq)?

    For anyone that is measuring sound, you’ve probably come across the term Leq or Equivalent Continuous Sound Level. But what is it and how can it help us when measuring noise with a sound level meter? Setting the Scene Imagine you work on a busy construction site that is operating all day. You have diggers, cranes, trucks and other ...


    By Cirrus Research plc

  • Case Study - Amistad Dam: Scan for Leaks in Earthen Dam

    At the Amistad Dam site an investigation was made with a 56 electrode STING/Swift system to determine the location of leaks which have effectively drained the giant dam of water. As it was not immediately obvious which array type would return the best data three different arrays were recorded on the same electrode layout. The resulting three 2D profiles show both similarities and differences. The ...


    By Advanced Geosciences, Inc.

  • Does traditional calibration hide errors in your demand analysis?

    Untitled Document A well-calibrated water distribution model can address numerous ...


    By Innovyze

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you