autosampler Articles
-
Validation of USEPA Method 524.2 Using a Stratum PTC and the New AQUATek 100 Autosampler
Abstract Automation is the key to increasing laboratory productivity and minimizing costs. It is equally important to prove that the changes in technology to achieve these results may be done without sacrificing sample integrity or data quality. The AQUATek 100 is a new vial autosampler which features many new benefits to help increase productivity, minimize carryover, and provide more ...
-
Increased laboratory productivity for ICPOES applied to U.S. EPA method 6010C
The use of an ESI SC FAST autosampler coupled to a Perkin Elmer Optima 7300 DV ICP can dramatically improve productivity for the analysis of environmental samples using EPA SW-846 Method 6010C. Sample throughput, as determined by sample-to-sample run time can be improved by as much as 100% as compared to traditional sample introduction systems and autosampler configurations. Both sample analysis ...
-
Increased laboratory productivity for ICPOES applied to U.S. EPA method 6010C
The use of an ESI SC FAST autosampler coupled to a Perkin Elmer Optima 7300 DV ICP can dramatically improve productivity for the analysis of environmental samples using EPA SW-846 Method 6010C. Sample throughput, as determined by sample-to-sample run time can be improved by as much as 100% as compared to traditional sample introduction systems and autosampler configurations. Both sample analysis ...
-
Comparison of the CMVX-7100 Micro-Volume Workstation
Comparison of the CETAC MVX-7100 Micro-Volume Workstation with an Established Laboratory Method for the Assessment of Lead, Mercury, and Arsenic in Human Whole Blood. Conventional autosamplers used in clinical ICP-MS are largely based on the needs of non-clinical environments. Their disadvantages are numerous and include high sample volume consumption, large dead volumes resulting in wasted ...
-
Residual indicator bacteria in autosampler tubing: a field and laboratory assessment
Microbial contamination in surface waters has become a worldwide cause for concern. As efforts are made to reduce this contamination, monitoring is integral to documenting and evaluating water quality improvements. Autosamplers are beneficial in such monitoring efforts, as large data sets can be generated with minimized effort. The extent to which autosamplers can be utilized for microbial ...
-
Using Alternative Carrier Gases for US EPA VOC Drinking Water Methods
Abstract Limited supplies and the rising cost of helium have spurred the need for analytical methods allowing more economical alternatives. With this in mind, new purge and trap VOC methods are being developed and evaluated using nitrogen purge gas, replacing helium. Building upon this new methodology, replacing the helium carrier gas with hydrogen or nitrogen offers the potential for additional ...
-
New Automation Guide for Improved Titration Workflows
Find valuable tips and tricks on how to optimize your titration workflows in the new METTLER TOLEDO Automation Guide. Download the Titration Automation Guide today and learn how titration processes can be automated for highest efficiency and security in the laboratory. Modern laboratories look into automation to address the demands for high throughput and variety of samples and workflows. ...
-
Shenzhen Environmental Monitoring Center - Case Study
Shenzhen Environmental Monitoring Center is one of the earliest institutions in China to apply the three-stage cryogentic trap preconcentration technology for environmental air analysis and monitoring. Nutech’s Air Lab Prep Suite (Autosampler, Preconcentrator, Precision Static Dilutor & Canister Cleaning System) has been serving for more than 10 years. ...
-
Understanding Intellidilution for Use with the Torch High Temperature Combustion Analyzer
Introduction The Torch is a High Temperature Combustion (HTC) Analyzer that utilizes a patent pending Static Pressure Concentration (SPC) technology for the analysis of carbon and nitrogen. The Torch Analyzer contains a built in autosampler with three vial rack options and PC driven controls. Automated calibration and Intellidilution, which automatically dilutes over-range samples to within the ...
-
Using Alternative Carrier Gas for US EPA 524.3
Abstract Due to regional shortages and increasing costs of helium, the preferred carrier gas in gas chromatography, alternative carrier gas options are in ever increasing demand. This study will evaluate the Teledyne Tekmar Atomx Multimatrix Autosampler in conjunction with a Thermo Scientific TRACE 1310 / ISQ GC/MS, while employing hydrogen carrier gas and nitrogen purge gas to perform USEPA ...
-
Increased sample throughput for ICP-OES applied to U.S. EPA method 200.7
The application of an SC-FAST sample introduction system to the analysis of natural and certified water samples is described. The SC-FAST system consists of an autosampler, sample loop, switching valve, high efficiency nebulizer and a glass cyclonic spray chamber to perform analysis by direct nebulization. The potential benefits of this introduction system are numerous and include: increased ...
-
Increased sample throughput for ICP-OES on drinking water and waste water
The application of an SC-FAST sample introduction system to the analysis of natural and certified water samples is described. The SC-FAST system consists of an autosampler, sample loop, switching valve, high efficiency nebulizer and a glass cyclonic spray chamber to perform analysis by direct nebulization. The potential benefits of this introduction system are numerous and include: increased ...
-
Calibrating Gasoline Range Organics (GROs) using an automated dilution scheme with the Atomx Concentrator/Multimatrix Autosampler
Abstract In developing the Atomx Automated Sample Prep System, Teledyne Tekmar integrated both a P&T concentrator and a multi-matrix autosampler into a single platform system that can be used in the analysis of soil, water, and soils requiring methanol extraction. This “all-in-one” setup has allowed for greatly increased throughput and efficiency through the built in features it ...
-
Comparison of Mold Odor Analysis in Water by Purge and Trap (PTC) and Solid-Phase Microextraction (SPME)
Abstract Taste and odor are important to consumers when it comes to drinking water. Two compounds that are responsible for many taste and odor issues are geosmin and 2-methylisoborneol. Both of these compounds are produced by microbes and have very low odor thresholds. Because of this, many drinking water laboratories require detection levels of below 10ppt. Analysis of these compounds is usually ...
-
Micro‐Volume Injection System for ICP‐MS
The MVX‐7100 L Workstation when paired with a DS‐5 total consumption nebulizer creates a paradigm shift in ICP‐MS sample introduction. It is a long overdue tool for trace element researchers wanting to measure elements at trace levels in microliter sized samples. In this study the MVX‐7100 is used with quadrupole ICP‐MS for injection of 20 L and 100 ...
-
High Throughput LC-MS-MS Analysis of Carbendazim in Orange Juice
Highly sensitive analytical methods are necessary to prevent contaminated produce from entering the food supply. In order to help move fresh imports through customs without delay, methods must be rapid and cost effective, in order to test imports thoroughly. LC-MS offers the highly sensitive, robust measurement needed, while ultra high performance liquid chromatography enables high speed ...
-
An Alternative Method to RSK 175 using a Purge and Trap Concentrator and GC/FID
Abstract With the growing price of oil, many alternative energy sources are being explored. Natural gas prices are actually decreasing, in large part to the use of hydraulic fracturing in areas like the Marcellus Shale in Pennsylvania. Due to increased concern over the hydrofracturing process and the release of methane and other chemicals into the local drinking water, a need has developed for ...
-
An Inert Desolvating Nebulizer System and Rapid Washout Accessory for Tungsten Isotope Measurements with Multicollector ICP-MS
Abstract: Multicollector ICP-MS instruments are specialized devices for high-precision isotope ratio measurements. Prepared liquid samples may be concentrated (100 to 1000 µg/L) in elements of interest; these higher concentrations can cause longer analyte washout times and signal spikes. This poster will describe an inert, low flow (50 to 200 µL/min) desolvating nebulizer system with ...
-
Improved performance in the analysis of drinking waters and wastewaters by U.S. EPA Method 200.8 with an SC-FAST System
The application of an SC-FAST introduction system to the analysis of natural and certified water samples is described. The SC-FAST system consists of an autosampler, a switching valve, a high efficiency PFA-ST nebulizer and Peltier-cooled cyclonic spray chamber to perform analysis by direct nebulization. The potential benefits of this introduction system are numerous and include increased ...
-
US EPA Method 8260 with the Teledyne Tekmar Lumin P&T Concentrator, AQUATek LVA and the Agilent 7890B GC/5977A MSD
Abstract US EPA Method 8260 was used to determine the concentration of volatile organic compounds (VOCs) in water samples. The Teledyne Tekmar Lumin purge and trap (P&T) concentrator, along with an AQUATek LVA liquid autosampler and an Agilent 7890B Gas Chromatograph (GC)/5977A Mass Spectrometer (MS) was used to create a working linear calibration curve and method detection limits (MDLs) for ...