autosampler Articles

  • Residual indicator bacteria in autosampler tubing: a field and laboratory assessment

    Microbial contamination in surface waters has become a worldwide cause for concern. As efforts are made to reduce this contamination, monitoring is integral to documenting and evaluating water quality improvements. Autosamplers are beneficial in such monitoring efforts, as large data sets can be generated with minimized effort. The extent to which autosamplers can be utilized for microbial ...


    By IWA Publishing

  • Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

    The US EPA developed Method 524.2¹, “Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry”, for identifying and measuring purgeable volatile organic compounds (VOC) in surface water, groundwater, and drinking water. Due to the required sensitivity of this method, the use of purge and trap gas chromatography is vital. This ...


    By Teledyne Tekmar

  • Comparison of the CMVX-7100 Micro-Volume Workstation

    Comparison of the CETAC MVX-7100 Micro-Volume Workstation with an Established Laboratory Method for the Assessment of Lead, Mercury, and Arsenic in Human Whole Blood. Conventional autosamplers used in clinical ICP-MS are largely based on the needs of non-clinical environments. Their disadvantages are numerous and include high ...


    By Teledyne CETAC Technologies

  • New Automation Guide for Improved Titration Workflows

    Find valuable tips and tricks on how to optimize your titration workflows in the new METTLER TOLEDO Automation Guide. Download the Titration Automation Guide today and learn how titration processes can be automated for highest efficiency and security in the laboratory. Modern laboratories look into automation to address the demands for high throughput and variety of samples and workflows. ...


    By Mettler - Toledo Int. Inc

  • Increased laboratory productivity for ICPOES applied to U.S. EPA method 6010C

    The use of an ESI SC FAST autosampler coupled to a Perkin Elmer Optima 7300 DV ICP can dramatically improve productivity for the analysis of environmental samples using EPA SW-846 Method 6010C. Sample throughput, as determined by sample-to-sample run time can be improved by as much as 100% as compared to traditional sample introduction systems and autosampler configurations. Both sample analysis ...


    By PerkinElmer, Inc.

  • Increased laboratory productivity for ICPOES applied to U.S. EPA method 6010C

    The use of an ESI SC FAST autosampler coupled to a Perkin Elmer Optima 7300 DV ICP can dramatically improve productivity for the analysis of environmental samples using EPA SW-846 Method 6010C. Sample throughput, as determined by sample-to-sample run time can be improved by as much as 100% as compared to traditional sample introduction systems and autosampler configurations. Both sample analysis ...


    By PerkinElmer, Inc.

  • Increased sample throughput for ICP-OES on drinking water and waste water

    The application of an SC-FAST sample introduction system to the analysis of natural and certified water samples is described. The SC-FAST system consists of an autosampler, sample loop, switching valve, high efficiency nebulizer and a glass cyclonic spray chamber to perform analysis by direct nebulization. The potential benefits of this introduction system are numerous and include: increased ...


    By PerkinElmer, Inc.

  • High Throughput LC-MS-MS Analysis of Carbendazim in Orange Juice

    Highly sensitive analytical methods are necessary to prevent contaminated produce from entering the food supply. In order to help move fresh imports through customs without delay, methods must be rapid and cost effective, in order to test imports thoroughly. LC-MS offers the highly sensitive, robust measurement needed, while ultra high performance liquid chromatography enables high speed ...

  • Improved performance in the analysis of drinking waters and wastewaters by U.S. EPA Method 200.8 with an SC-FAST System

    The application of an SC-FAST introduction system to the analysis of natural and certified water samples is described. The SC-FAST system consists of an autosampler, a switching valve, a high efficiency PFA-ST nebulizer and Peltier-cooled cyclonic spray chamber to perform analysis by direct nebulization. The potential benefits of this introduction system are numerous and include increased ...


    By PerkinElmer, Inc.

  • Increased sample throughput for ICP-OES applied to U.S. EPA method 200.7

    The application of an SC-FAST sample introduction system to the analysis of natural and certified water samples is described. The SC-FAST system consists of an autosampler, sample loop, switching valve, high efficiency nebulizer and a glass cyclonic spray chamber to perform analysis by direct nebulization. The potential benefits of this introduction system are numerous and include: increased ...


    By PerkinElmer, Inc.

  • Determination of Ammonia and Nitrogen

    Customer: CAE Grand Ouest, France CAE is a laboratory of the Veolia Group located in Western France. The laboratory is specializing in environmental analysis, especially in water and soil analysis. Application: Determination of Ammonia and TKN in waste water and soil Total Kjeldahl Nitrogen (TKN) and Ammonia are common parameters for the evaluation of ...


    By BÜCHI Labortechnik AG

  • Advances in Bromine Speciation by HPLC/ICP-MS

    Bromine is a natural component found in waters, most commonly as the bromide ion, Br-. A common procedure for purifying drinking waters is treatment with ozone to kill bacteria. A byproduct of ozonolysis is the conversion of bromide to bromate (BrO3-), a known carcinogen. Therefore, a need exists to measure both bromide and bromate in drinking waters, as opposed to total bromine content. Our ...


    By PerkinElmer, Inc.

  • MVX-7100 Micro-Volume Injection System for ICP-MS

    Micro-Volume Injection System for ICP-MS. The MVX-7100 Workstation when paired with a DS-5 total consumption nebulizer creates a paradigm shift in ICP-MS sample introduction. It is a long overdue tool for trace element researchers wanting to measure elements at trace levels in microliter sized samples. In this study the MVX-7100 is used with quadrupole ICP-MS for injection of 20 micro L and 100 ...


    By Teledyne CETAC Technologies

  • Analysis of biogenic amines food and physiological samples

    Histamine and other polyamines such as Putrescine, Cadaverine, Spermidine and Spermine are products of decomposition. The level of histamine, in particular, has been used as a regulatory guideline for degree of decomposition in fish. Also, Histamine and Tyramine levels are of interest to producers of wine and cheese. The polyamines, Spermidine, Spermine and Putrescine are elevated in neoplastic ...


    By Pickering Laboratories, Inc.

  • Calibration stability of the sievers 900 series TOC analyzers

    Objective One of the advantages of the membrane conductivity measurement system employed in the Sievers 900 Series TOC Analyzers, compared to other TOC analyzers, is the excellent stability of the calibration. To illustrate this, a series of tests were conducted on three 900 Series analyzers over the course of a 14-month period and the results are  summarized in this report . The 900 ...


    By GE Analytical Instruments

  • Aminoglycoside Antibiotics in Feed Apramycin, Gentamicin, Neomycin

    Aminoglycoside antibiotics are among those commonly used in animal feeds to manage intestinal microorganisms. The beneficial effects include improved growth and generally healthier animal populations. Use of antibiotics creates a demand for analytical procedures to verify concentrations in pre-mixes and feeds and in some instances for residue analysis in animal products. This note describes a ...


    By Pickering Laboratories, Inc.

  • Tips to maintain your HPLC & UHPLC systems and columns

    Recently, Ade Kujore (Cecil Instruments), Tracie Brombos (GenTech Scientific) and I were asked by Angelo De Palma, a well-respected writer for Lab Manager magazine, to contribute to an article about maintaining and caring about your laboratory instruments. Here are my tips/best practices for column and HPLC/UHPC/UPLC system maintenance. Maintaining your ...


    By Waters Corporation

  • Increased sample throughput for ICP-OES applied to U.S. EPA method 200.7

    The application of an SC-FAST sample introduction system to the analysis of natural and certified water samples is described. The SC-FAST system consists of an autosampler, sample loop, switching valve, high efficiency nebulizer and a glass cyclonic spray chamber to perform analysis by direct nebulization. The potential benefits of this introduction system are numerous and include: increased ...


    By PerkinElmer, Inc.

  • Analysis of Na, K, Ca and Mg in Mineralwater using the Microsampling Method

    Sodium, Potassium, Calcium, and Magnesium belong to the essential mineral substances in the human organism. These elements take influence in the generation of enzymes and hormones, control the osmotic pressure in tissues and body fluids and are important for the exchange procedures in the cell membranes. In this application, the control of Na, K, Ca and Mg in a variety of mineral waters has been ...

  • Water and environmental analysis according to US EPA regulations using the lambda 25/35/45 UV/Vis spectrophotometers

    UV/Vis spectroscopy is an important analytical technique used for the determination of many water constituents. Environmental regulations in many countries prescribe the use of UV/Vis spectroscopy. Depending on the method, UV/Vis determinations of metal and organic nonmetal analytes in water have a minimum detectability in the ppb-ppm range. The Lambda UV/Vis Spectrophotometers ...


    By PerkinElmer, Inc.