baghouse bag Articles

  • Ineffective cleaning in generic baghouses

    ABSTRACT: Background In a typical “generic” baghouse application, the cleaning is accomplished by back-flushing the filter with compressed air that travels through an orifice hole in a purge tube (blow pipe) and through a venturi. A typical generic cleaning system allows dust to be filtered at an air-to-cloth ratio of 5:1. That means for every 5 CFM of airflow, there is 1 square foot ...


    By Scientific Dust Collectors

  • Improving the cleaning cycle in baghouse collectors

    ABSTRACT: Background The reverse pulse jet baghouse has been around for over 45 years and the cleaning cycle has not changed very much since that time. The cleaning cycle is the most important part of the dust collector because it controls efficiency and media life. In a generic baghouse, the cleaning system is comprised of a blowpipe that is located typically approximately three inches above ...


    By Scientific Dust Collectors

  • Advantages of cleaning without a venturi in baghouse collectors

    ABSTRACT: Background The cleaning cycle is the most important part of the dust collector because it controls efficiency and media life. In order to clean a row of bags in a reverse pulse jet baghouse first the flow of filtered air must be momentarily stopped and then back flushed or “induce” air to knock the dust cake off the outside of the filter media. A venturi at the top of the ...


    By Scientific Dust Collectors

  • New Nozzle Technology “Cleaning More with Less”

    This technical paper will explain the new nozzle technology developed by Scientific Dust Collectors that allows high air-to-cloth ratio baghouses to use 80psig of compressed air instead of the industry standard 100psig.   The reverse pulse jet baghouse has been around for over 50 years and the cleaning cycle has not changed very much during that time. The cleaning cycle is the most important ...


    By Scientific Dust Collectors

  • High-Tech Filters

    The current economic situation of the cement industry creates sensitivity regarding off-times and process stability. More stringent air-pollution laws, especially when using waste-derived fuels, are drawing more attention to the off-gas cleaning facilities, usually bag filters. This article does not deal with electrostatic precipitators - as even they have well known disadvantages. By using more ...


    By Evonik Fibres GmbH

  • Solid / gas separation with fabric filters

    A myriad of filter media are utilized today for separation of particulate matter in industrial gas filtration applications. These media range from single use (deposable) to semi-permanent media and include fiber, fabric, ceramic, membrane, metal mesh, and sintered metal media. Semi-permanent media are usually cleanable, either on or off-line, and are primarily intended for long-term (up to ...

  • Asbestos contaminated soil case study

    An active gypsum manufacturing facility discovered they had a large area of gypsum waste containing asbestos mixed with soil at the back of their property. The waste had accumulated over the years before the dangers of asbestos were known and now required remediation due to communication wires buried in the waste. Excavators could not be used due to the presence of the communication wires that ...


    By Enviro-Vac Corp.

  • To prevent blinding in dust collection systems, consider filter type, filter size and selection of the filter media used

    All dust collection systems, regardless of size, share a common problem—dust blinding. Simply stated, blinding is defined as when dust particles plug the holes in a filter and stop the flow of air through the filter, resulting in the dust collector performing poorly. All types of collectors, whether stand-alone units, cyclones or full-scale baghouses, are subject to blinding. To better ...


    By American Fabric Filter Co

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Controlling Stack Emissions in the Wood Products Industry

    Electrostatic precipitation has been a reliable technology since the early 1900's. Originally developed to abate serious smoke nuisances, the manufacturers of zinc, copper, and lead quickly found electric gas cleaning a cost efficient way to recover valuable product carried out of the stacks from furnace operations. Today electrostatic precipitators are found mainly on large power plants, cement ...


  • Difficult Complex Decisions For Coal-fired Power Plant Operators

    Changing fuel prices, government regulations and technology all combine to make decision making difficult for operators and developers of coal-fired power generation facilities around the world. Power plant designers in developing countries face new local environmental regulations plus additional requirements stipulated by lenders such as the World Bank. In the developed world, the regulations ...


    By The McIlvaine Company

  • A cure for Environmental Emissions case study

    Disposing of nearly 1 million pounds of medical waste a month is no easy task. The wet electrostatic precipitator, installed at Rochester, MN-based Mayo Clinic, seems to be just what the doctor ordered. While the medical waste incinerator at Mayo Clinic in Rochester, MN, consistently met state and federal emission requirements, facility leadership recognized that installing a wet electrostatic ...


    By Bionomic Industries Inc.

  • Manufacturing facility cleaning case study

    The Challenge A large Industrial manufacturing facility found that their process used to perform the necessary tasks was creating an undesirable accumulation of heavy metals dust throughout the entire plant. Not only was this a potential health risk to the plant workers, there was a structural and safety problem because the dust could spark and cause a fire or explosion. ...


    By Enviro-Vac Corp.

  • EPA Proposed “Franken-MACT” for Utilities

    EPA published the highly anticipated proposed Maximum Available Control Technology (MACT) Standard for the utility sector (40 CFR 63 Subpart UUUUU). When considered together with the growing list of proposed and final rules impacting the utility sector (Transport Rule/Cross-State Rule, Coal Combustion Byproducts Rule, Cooling Water Intake Rule, Regional Haze Rule, revised National Ambient Air ...


    By Trinity Consultants

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you