benchtop edxrf Articles

  • Using EDXRF to quantify the amount of Metals in Asphalt Binders

    This article reviews these sources and proposes a scheme for measuring and quantifying the amounts of metals in their source materials used to bind asphalt used in making roads. The use of bench top EDXRF to characterize binders before blending them into asphalt cements is possible because the metal values are in the 10s – 1000s of ppms and are readily monitored. ...


    By Xenemetrix Ltd.

  • P-METRIX - bringing edxrf lab analysis to the field

    The P-Metrix is wrapped in a portable case that acts as a self-contained EDXRF laboratory and allows you to roll it to any site for your elemental analysis test. P-Metrix, bridging new frontiers in lab-to-field analysis, will be presented at the 2017 ACS Spring Meeting, at San Francisco, April 2nd - 4th, booth # 1706. The analytical and industrial instrumentation from Xenemetrix range from ...


    By Xenemetrix Ltd.

  • In compliance with the ASTM D 4294-08 method at low concentrations of sulfur in diesel.

    This application note show the excellent performance of Xenemetrix EDXRF benchtop analyzers X-Calibur and S-Mobile for ultra low sulfur in diesel determinations according to the requirements of the ASTM method D4294-08.The applicable concentration range of the ASTM method is from 17.0 ppm to 4.6 mass%.  This  note show the performance at the very low concentration end ...


    By Xenemetrix Ltd.

  • Quantitative Analysis of Geological Samples- X-Calibur

    Abstract Quantitative and qualitative analysis of geological samples (rocks and river sediments) was performed on Xenemetrix EDXRF Benchtop Spectrometer System, model X-Calibur  Objective: Perform XRF measurements on certified geological reference materials to build calibration curves for the major oxides (Na2O, MgO, SiO2, Al2O3, SiO2, P2O5, ...


    By Xenemetrix Ltd.

  • Application Note - Comparison of minimum detection limits on X-Calibur with SDD detyector or Si-PIN diode detector

    ABSTRACT - The minimum detection limits of several different elements in water and in oil solutions were determined on X-Calibur with a SDD detector installed or a Si-PIN diode detector installed. The MDL was determined at 3 sigma and 300 seconds acquisition times. The result is reported here. OBJECTIVE - To perform a quantitative comparison between the performance of ...


    By Xenemetrix Ltd.

  • Minimum detection limits of several different elements in water and in oil

    Abstract  The minimum detection limits of several different elements in water and in oil solutions were determined on X-Calibur with a SDD detector installed or a Si-PIN diode detector installed. The MDL was determined at 3 sigma and 300 seconds acquisition times. The result is reported here. Objective  To perform a quantitative comparison between the ...


    By Xenemetrix Ltd.

  • Application note issue #5 - Cement Analysis August 2017

    Cement analysis using FP program (Fundamental Parameters) Cement is a blend of several minerals. It is critical to control the elemental composition and properties such as strength, setting, time and color. ED-XRF is being used to analyze the raw components, raw meal, clinker, and the final cement product (Na, Mg, Al, ...


    By Xenemetrix Ltd.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you