blowdown discharge Articles

  • Solar Power Plant Recycles Blowdown Water to Save Fresh Water - Case Study

    PROJECT DETAILS LOCATION Ashalim, Israel CUSTOMER GE-Alstom, Israeli Government SOLUTION Cooling tower wastewater treatment system TECHNOLOGIES Containerized Systems Featuring Automatic Disc Filtration and Ultrafiltration, Brackish Water Reverse Osmosis, Gas Transfer ...


    By Fluence Corporation

  • Zero discharge system handles german power station’s fgd wastewater

    Evaporator/Crystallizer Combined with Salt Exchange Pretreatment is the Answer for this Demonstration Plant. The Facility A major European utility has several power block units fitted with wet limestone FGD scrubbers at their 600 MW power station in southern Germany. The blowdown from the scrubbers is treated to remove the heavy metals and suspended solids. The ...

  • What are the best companies for Zero Liquid Discharge Equipment and Technology?

    With an increasing push for environmental protection, many industrial facilities and effluent regulators are making decisions that lessen their impact on the environment and human health. Changes and implementations are constantly being discussed and met both nationally and internationally to change the way industrial facilities discharge waste, and it is important to know which companies are the ...


    By SAMCO Technologies, Inc.

  • Five common problems with zero liquid discharge and how to solve them

    As more and more facilities are turning to zero liquid discharge (ZLD) for wastewater treatment and effluent reduction—whether it’s to comply with local discharge regulations or recycle and reuse as much water as possible in your process—more information is becoming available about the possible issues your facility might face while using ZLD technology. Because of the scope of ...


    By SAMCO Technologies, Inc.

  • Case study - Die casting wastewater treatment

    The Client Our Client is a company that operates in the field of aluminum products for the food industry since 1936 producing pots for local and foreign markets. The production line also includes all the mechanical processing from plates to finished products. The challenge The goal to be achieved was the reduction of the disposal ...


    By EVALED-Evaporator

  • Republic Steel: CapDI for Cooling Towers - Case Study

    Introduction & process description Water is often a hidden cost of industrial sites and can contribute significantly to operational costs. Cooling towers are used to reject heat through the natural process of evaporation providing cooled water across a broad range of applications. Due to evaporative losses, the water remaining in the cooling tower becomes concentrated with dissolved ...


    By Voltea B.V.

  • MBR at General Mills Covington USA

    Aquabio has designed and built an advanced membrane bioreactor plant with Building Crafts Inc. & Dynatec, NJ at the General Mills Cereal production facility at Covington GA, USA. The plant efficiently removes organics and suspended solids to very low levels suitable for ...


    By Aquabio Ltd

  • Ozone for cooling tower systems – an update and lessons learned at the kennedy space center

    KEYWORDS: Ozone, Cooling Water, Stand-Alone Treatment, and Large Capacity Cooling Tower SUMMARY: The operational experience and performance of the successful use of ozone as a stand-alone cooling water treatment method are discussed. Several guidelines for design parameters and operational controls are presented. From a wide field of application experience, the author ...


    By Zentox Corporation

  • Ozone for Cooling Tower Systems - An update and lessons learned at the Kennedy Space Center

    Keywords: Ozone, Cooling Water, Stand-Alone Treatment, and Large Capacity Cooling Tower Summary: The operational experience and performance of the successful use of ozone as a stand-alone cooling water treatment method are discussed. Several guidelines for design parameters and operational controls are presented. From a wide field of application experience, the author ...


    By Absolute Systems Inc.

  • Common Cooling Tower Water Treatment Problems and How to Solve Them

    For companies using cooling towers to remove heat from an industrial process or for cooling large buildings, there are several issues that can surface during the cooling tower water treatment process that we see on a regular basis. Because these issues occur often, it’s important to know what to look out for in advance, perhaps saving you some time and resources down the line. ...


    By SAMCO Technologies, Inc.

  • East coast power plant realizes 95% water recovery

    The Facility Bechtel Power Corporation builta power plant in Northampton, Pennsylvania for U.S. Generating Company. The power plant burns culm, a lower quality coal rejected from use in previous decades. By using culm as the fuel, U.S. Generating will clean up a solid disposal site. The power plant contains the usual systems including cooling towers and demineralizers that produce waste ...

  • California’s city of roseville chooses HERO ZLD

    The Facility The Roseville Energy Park (REP) will be a natural gas-fired, combined-cycle electrical generating facility. The project, planned for a 12-acre site, will be owned by the city and will use state-of-the-art equipment to locally generate about 60 percent of Roseville’s electricity needs. The Roseville Energy Park will use recycled wastewater from the nearby Pleasant Grove ...

  • A New Day Dawns

    As demand for water increases nationwide and around the globe, tougher restrictions have been placed on several industries to incentivize reuse and repurposing and discourage contaminant discharge. Across the country, regional power companies are turning to outside experts for solutions that meet their competing needs of being environmentally friendly and economically feasible. For example, GE ...


    By Modern Pumping Today

  • Stormwater Solids Reduction for NPDES Permits

    Finally obtaining a National Pollution Discharge Elimination System (NPDES) Permit is often a relief but is by far not the end of the story. Meeting the requirements of that permit often proves to be quite difficult and stiff fines are freely doled out to those who fail to meet regulatory limits. For one Midwest jet propulsion manufacturing facility, the issue of total daily solids discharge ...

  • Ozone treatment for cooling towers

    Abstract The use of ozone as a maintenance treatment for cooling towers has good potential for operation and maintenance savings in the Federal secior. A small amount of ozone acts as a powerful biocide thai decreases or nearly eliminates the need to remove quantities of water from the cooling tower in order to decrease the concentration of organic and mineral solids in the system. ...


    By Zentox Corporation

  • What Is a Cooling Tower Water Treatment System and How Does It Work?

    For industrial companies using a cooling tower for its facility, some type of cooling tower water treatment system is usually necessary to ensure an efficient process and long equipment service life. If cooling tower water is left untreated, organic growth, fouling, scaling, and corrosion can reduce plant productivity, cause plant downtime, and require costly equipment replacements down the ...


    By SAMCO Technologies, Inc.

  • Coal fired power plant achieves ZLD for FGD wastewater

    The Facility Illinois’ City of Springfield’s Dallman Power Station’s three coal-fired units and soon to be installed fourth unit, are equipped with flue gas desulfurization (FGD) systems (scrubbers) to control sulfur dioxide (SO2) emissions. The Problem A sharp increase in boron concentration in the FGD wastewater required that The City ...

  • High Rate Clarifier Start-up and Operation in Shreveport, Louisiana

     ABSTRACT In 2004, the city of Shreveport received permits from the Louisiana Department of Environmental Quality and the U.S. Environmental Protection Agency to construct and operate a high rate clarifier (HRC) at both the North Regional and Lucas wastewater treatment plants. The HRC provides wastewater treatment for flow in excess of the peak plant capacities. Each HRC unit uses ...

  • New Energy BFP - Case Study

    Clarification and Dewatering Control Industrial TSS The New Energy Corporation facility in South Bend IN produces 380,000 M3 per year (100 million gallons per year) of ethanol from corn feedstock. It also produces about 272,000 tonnes per year (300,000 tons per year) of carbon dioxide and 299,000 tonnes per year (330,000 tons per year) of distillers' dried grains with solubles (DDGS) as ...


    By Komline-Sanderson

  • How Do You Know If You Need a Cooling Tower Water Treatment System for Your Plant?

    In order to keep your production flowing smoothly and avoid costly damage to your cooling tower equipment, the proper treatment of your cooling tower water is essential. If cooling tower water is not properly treated, organic growth, fouling, scaling, and corrosion can reduce plant productivity, cause plant downtime, and require costly equipment replacements down the road. ...


    By SAMCO Technologies, Inc.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you