calibration kit Articles

  • How Often You Should Calibrate A Sound Level Meter

    Do you calibrate a sound level meter frequently? Most sound level meter users know they must calibrate their sound level meters but a questions I frequently get asked if “how often?” Here’s my best practice advice so you can calibrate with confidence. What Do We Mean by Sound Level Meter ...


    By Cirrus Research plc

  • `Good to Go™ tags´ manage your daily or weekly calibration and safety checks

    Keeping up with safety regulations can be complicated and time-consuming. Having an easy to complete, simple visual guide to carry out safety or calibration checks solves this problem and helps to keep the workplace safe. One glance and you can see the equipment is “Good to ...


    By Camlab Limited

  • How to Set Up an Outdoor Sound Monitoring Kit

    What do demolition sites, construction, industrial and mechanical equipment, outdoor events, transportation facilities, traffic, and air crafts have in common? They all cause noise pollution. Environmental noise can cause adverse effects to those around it which is why it is critical monitor. At RAECO Rents we make outdoor sound monitoring easy! ...


    By Raeco Rents

  • Preparation of <25x or >100x dilutions with the rapid prep universal range extension kit

    GENERAL COMMENTS: This procedure describes how to prepare dilutions of less than 25x or greater than 100x using the appropriate RaPID AssaysÒ Sample Diluent and components of the RaPID PrepÔ Universal Range Extension Kit. Preparing dilutions of 25x to 100x are already described in the package insert of the Universal Range Extension Kit. Serial dilutions using components of the ...


  • Use of PCB RaPID ASSAY kits for semi-quantitative screening consistent with SW-846 method 4020

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Use of TNT RaPID ASSAY kits for semi-quantitative screening consistent with SW-846 method 4050

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Use of SDI 2,4-d rapid assay kits for semi-quantitative screening consistent with SW-846 METHOD 4015

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators and reports results in semi-quantitative ranges lying above, below or ...


  • Use of SDI pentachlorophenol rapid assay kits for semi-quantitative screening consistent with sw-846 method 4010

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators and reports results in semi-quantitative ranges lying above, below or ...


  • Use of PAHs RaPID ASSAY kits for semi-quantitative screening consistent with SW-846 Methood 4035

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Use of SDI total btex/tph rapid assay kits for semi-quantitative screening consistent with sw-846 method 4030

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Use of SDI carcinogenic PAHs RaPID assay kits for semi-quantitative screening consistent with SW-846 method 4035

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Nottinghamshire County Council Chooses Casella Sound Level Meter Kits - Case Study

    When Nottinghamshire County Council needed to upgrade its 20-year-old noise monitoring equipment, it made sense to choose two of the latest high performance 63x series sound level meter kits from previous supplier, Casella - leading global specialist in occupational health and environmental risk management solutions Nottinghamshire County Council is the Minerals and Waste Planning Authority ...


    By Casella

  • Detection of chlordane in water

    MATRIX: Water (surface, ground and drinking) ANALYTE: Chlordane RANGE OF DETECTION: 2.0 to 60.0 ppb MATERIALS: EnviroGard Chlordane in Soil Test Kit (Item #73110) Methanol (pesticide grade) Glass vials with teflon lines caps PROCEDURAL NOTES: Water samples should be collected in glass ...


  • Detection of DDT in water

    MATRIX: Water (surface, ground and drinking) ANALYTE: DDT RANGE OF DETECTION: 10 to 500 ppb MATERIALS: EnviroGard DDT in Soil Test Kit (Item #73100). Methanol (pesticide grade). Glass vials with teflon lines caps. PROCEDURAL NOTES: Water samples should be collected in glass vessels with teflon cap ...


  • Testing Tar & Asphalt for Polyaromatic Hydrocarbons

    New regulations by the European Union require laboratory testing for polyaromatic hydrocarbons (PAHs) when recycling or disposing old tar or asphalt from road planings. Sitelab’s portable UVF-3100D and TD-500D analyzers have similar sensitivity to these types of compounds. The equipment is easy to operate and samples can be tested in the field in less than ...

  • Case study - TPH in produced sand for overboard discharge

    Customer uses TD-500D to measure TPH concentrations in produced sand on an offshore oil platform in Malaysia.  The sand contains high levels of crude oils and must be treated on-site prior to dumping it overboard.  The TD-500D was calibrated to Sitelab's TPH calibration kit, product CAL-056.  Methanol solvent was used to extract the samples.  For comparison, samples were also ...


    By Sitelab Corporation

  • Case study - EPH in soil with No. 6 fuel oil

    No. 6 fuel oils (heavy fuel oil, bunker C oil) is often used in industry for heat, steam or power generation. A consultant used Sitelab to investigate two different spill sites contaminated with subsurface plumes of NAPL resulting from leaking underground storage tanks (USTs). Soils were collected from borings using a drill rig and field screened for their EPH aromatic content. Split samples ...


    By Sitelab Corporation

  • Grab £1000 of free benefits with the dBAdvantage Card from Cirrus Research

    The dBAdvantage Card from Cirrus is the quick and easy way to grab £1000 of FREE benefits when you buy a Cirrus sound level meter or doseBadge noise dosimeter kit. As a dBAdvantage Card member you’ll automatically get access to the following benefits: 1. A FREE place, each ...


    By Cirrus Research plc

  • Analysis of PCB in water using the envirogard test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Aroclor 1248: 1 ppm Aroclor 1260: 2 ppm Aroclor 1242: 2 ppm Aroclor 1254: 1.1 ppm BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A chemical reaction is induced that causes a color change ...


  • Case study - EDRO in soil at wharf remediation site

    Sitelab Calibration Kit CAL-042 is used for EDRO analysis. The UVF-3100 detects hydrocarbons in the C10-C36 range. A Licensed Site Professional (LSP) used Sitelab to investigate a commercial waterfront property, contaminated with a plume of LNAPL resulting from fuel tanks which once stored heating oil, diesel and gasoline dating back to the 1950s. The site is in Massachusetts, where laboratories ...


    By Sitelab Corporation