chemical oxygen demand analyzer Articles

  • What is Chemical Oxygen Demand (COD)?

    Chemical Oxygen Demand (COD) analysis is a measurement of the oxygen-depletion capacity of a water sample contaminated with organic waste matter. Specifically, it measures the equivalent amount of oxygen required to chemically oxidize organic compounds in water. Why Measure COD? COD is used as a general indicator of water quality and is an integral part of all water quality ...


    By MANTECH Inc.

  • PeCOD® Analyzer 15-minute chemical oxygen demand (C0D) analysis

    The revolutionary PeCOD® Analyzer technology provides Chemical Oxygen Demand results in under 15 minutes in a Simple-Safe-Effective manner. With our mercury and dichromate free chemistry installed in over 20 countries, the PeCOD® Analyzer has delivered successful test monitoring of COD in a variety of environments with our approved and published MOECC method  Through our proprietary ...


    By MANTECH Inc.

  • Application of chemical oxygen demand to drinking water

    “This study investigated the use of a photoelectrochemical chemical oxygen demand (peCOD) analyzer for the detection of model organic compounds and natural organic matter (NOM) from four drinking water treatment plants in Nova Scotia, Canada. Most model organic compounds showed ...


    By Camlab Limited

  • Chemical Oxygen Demand and Biochemical Oxygen Demand results in 15 minutes - Case Study

    Arauco, a Chilean pulp and paper company, has been using a PeCOD® Analyzer in full-scale operations since 2013. As a result, the company has reduced the use of hypochlorite in its bleaching processes with no loss of product quality, and decreased the amount of organics in its wastewater stream. The net result was a further reduction in chemicals and energy used in water treatment that saved ...


    By MANTECH Inc.

  • Online Chemical Oxygen Demand for Treatment Optimization - Case Study

    A wide variety of products are made in the chemical and pharmaceutical manufacturing industries, that require large volumes of chemicals, materials, and substances that are used throughout process operations. Waste water from these facilities typically include contaminants, toxins, nutrients, and organic content that presents challenges with regards to treatment. A major UK based chemical ...


    By MANTECH Inc.

  • PeCOD® Analyzer oxygen demand analysis for source & treated drinking waters

    MANTECH’s chemical oxygen demand (COD) analyzer is breaking new ground in the science of monitoring source and treated drinking water. In addition to providing 15-minute COD results and biochemical oxygen demand (BOD) estimates, MANTECH’s PeCOD® Analyzer measures natural organic matter (NOM) in raw and treated drinking water. The NOM Analyzer™  — which is the ...


    By MANTECH Inc.

  • Surface Water Monitoring - Case Study

    Safe operation of a Water Treatment Plant (WTP) requires careful monitoring of the water supply influent to the plant, as a guard for any substances entering the treatment works that could negatively impact treated water quality in the distribution system. One aspect of water quality that has recently garnered more attention from authorities and utilities is Natural Organic Matter (NOM), which ...


    By MANTECH Inc.

  • Food & Beverage Industry: Soft Drink - Case Study

    The peCOD (photoelectric Chemical Oxygen Demand) method for COD analysis is well suited to the soft drink industry as it provides plant operators with quick and reliable COD results important for process monitoring and control. Continuous COD monitoring of wastewater can protect production plants by ensuring COD discharge levels meet the acceptable limits, and by detecting product leakage. It can ...


    By MANTECH Inc.

  • Development and Application of Oxygen Demand Testing using Industrial Effluent - Case Study

    Abstract The purpose of this study is to develop capacity and protocols for oxygen demand testing that can be used for instruction and research within the BioScience Technology program. For application purposes we chose the PeCOD® Analyzer which offers a unique nanotechnology-based approach to Chemical Oxygen Demand (COD) analysis. Background ...


    By MANTECH Inc.

  • Analysis of nitrogenous and algal oxygen demand in effluent from a system of aerated lagoons followed by polishing pond

    In this descriptive-analytical study, nitrogenous and algal oxygen demand were assessed for effluent from a system of facultative partially mixed lagoons followed by the polishing pond using 120 grab samples over 1 year. Filtered and non-filtered samples of polishing pond effluent were tested in the presence and absence of a nitrification inhibitor. Effective factors, including 5-day biochemical ...


    By IWA Publishing

  • TOC analyzer for airports

    During winter, de-icing processes at airports necessitate storm water and de-icing water management. Especially due to adhesive (sticky) substances, strongly fluctuating concentrations and a lot of chemicals, the monitoring systems itself must be tailor-made to fight this water analysis challenge. LAR 's ...


    By LAR Process Analysers AG

  • Titanium Demand on Rise for Additive Manufacturing Printing: How it’s Made? Titanium Plasma Atomization.

    Plasma atomization is used in many applications, including 3D printing. First developed in 1998, this technique has risen to become the industry standard process for creating reactive metal powders suitable for 3D printing. Learn how plasma atomization works and why you need an oxygen monitor to stay safe with plasma atomization.  How Plasma Atomization Works ...

  • Analysis of chemical reaction kinetics of depredating organic pollutants from secondary effluent of wastewater treatment plant in constructed wetlands

    Four subsurface constructed wetlands were built to treat the secondary effluent of a wastewater treatment plant in Tangshan, China. The chemical pollutant indexes of chemical oxygen demand (COD) were analyzed to evaluate the removal efficiency of organic pollutants from the secondary effluent of the wastewater treatment plant. In all cases, the subsurface constructed wetlands were efficient in ...


    By IWA Publishing

  • Case study - Cost-saving solutions using Sievers InnovOx TOC analyzers - optimizing organic loading

    Cost Concern  A company’s inability to recognize real-time organic loading changes in their wastewater treatment plant could result in excessive charges from the local water utility. Company Challenge A production facility located in the U.S. Midwest currently controls the organic loading in their wastewater’s chemical treatment ...


    By GE Analytical Instruments

  • PeCOD vs Other Organic Pollution Testing Methods

    Find out How MANTECH’s PeCOD measures up with other systems in organic pollution testing methods! In James Pickup, Rijkswaterstaat Internship Thesis, read how our PeCOD analyzer performs beside the Total Organic Carbon (TOC) method. Also learn how the PeCOD exhibits a strong correlation to the traditional chemical oxygen demand (CODCr) method, Biochemical Oxygen Demand (BOD5) method and ...


    By MANTECH Inc.

  • Non-linear modeling using fuzzy principal component regression for Vidyaranyapuram sewage treatment plant, Mysore – India

    Fuzzy principal component regression (FPCR) is proposed to model the non-linear process of sewage treatment plant (STP) data matrix. The dimension reduction of voluminous data was done by principal component analysis (PCA). The PCA score values were partitioned by fuzzy-c-means (FCM) clustering, and a Takagi–Sugeno–Kang (TSK) fuzzy model was built based on the FCM functions. The ...


    By IWA Publishing

  • PeCOD® Pulp and Paper Applications - Case Study

    The pulp and paper industry utilizes wood as raw material to produce pulp, paper, card board, and other cellulose based products. Pulp and paper mills produce large volumes of wastewater and residual sludge which presents a number of challenges with regards to treatment and discharge. Contaminants in pulp and paper waste streams often include effluent solids, sediments, absorbable organic halides ...


    By MANTECH Inc.

  • Reclaimed municipal wastewater for forage production

    This study aims to evaluate the possibility of using reclaimed municipal wastewater for agricultural purpose. We assessed the validity of municipal wastewater treatment, analyzing its chemical characteristics before and after the biological stabilization by pond treatment (WSP). The reclaimed municipal treated wastewater (TWW) was used to irrigate Cenchrus ciliaris. Experiments were carried ...


    By IWA Publishing

  • Quality and first flush analysis of stormwater runoff from a tropical commercial catchment

    This paper examines the storm runoff quality from a commercial area in south Johor, Malaysia. Six storm events with a total of 68 storm runoff samples were analyzed. Event Mean Concentration (EMC) for all constituents analysed showed large inter-event variation. Site mean concentrations (SMC) for total suspended solids (TSS), oil and grease (O&G), biochemical oxygen demand (BOD), chemical oxygen ...


    By IWA Publishing

  • Two different purification systems at Istanbul-Tuzla and Adana-Kozan, their characterizations

    In most developed countries, wastewater treatment plants are presently utilizing efficient purification technology meeting the sufficiency requirements of quality and quantity. However, in developing countries, the number of wastewater treatment plants is limited. As a result, the establishment of a connection between the wastewater collection system and wastewater purification plants is ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you