chlorine vapor monitoring Articles

  • Using bioaugmentation to reduce risks and costs associated with vapor intrusion

    The risk driver for remedial action on many sites is potential vapor intrusion hazard. While mitigation of the vapors entering the structure can reduce the risk to an acceptable level, there are associated long-term monitoring, operation and maintenance costs. Bioremediation of the source of vapors can reduce the risk and eliminate long-term costs. The vapor intrusion risk is managed by ...


    By CL Solutions, LLC

  • Air Monitoring for the Gulf Oil Spill

    Ambient air monitoring is a priority in the ongoing efforts to contain and manage the oil spill from the Deepwater Horizon in the Gulf of Mexico. The following provides information about the kinds of airborne contaminants that are currently being monitored in the Gulf, how they are collected and how they are analyzed. For a given project, a suitable sampling plan – developed by ...


  • Risk-Based Closure Considerations For Monitored Natural Attenuation

    ABSTRACT Recent advances in both the chemistry- and hydrogeology-based aspects of monitored natural attenuation (MNA) and in toxicology research have changed some of the traditional approaches to MNA for petroleum and chlorinated groundwater plume management. For MNA to be approved as a remedial approach, human health and the environment must still be protected. To demonstrate protection, ...


    By Weston Solutions, Inc

  • Continuous emission monitoring and control of packed tower odor control systems using the sycamore CEM

    ABSTRACT Packed-tower chemical scrubbers, with sodium hydroxide (caustic) and sodium hypochlorite (bleach), are commonly used to treat foul air from wastewater treatment processes. The available control mechanisms include a pH probe and controller for the sodium hydroxide feed, an oxidation reduction potential (ORP) probe with a controller toestablish the bleach feed, and proprietary ...

  • Plant for the Istanbul waterworks

    Shock chlorination for a water quantity of 55,000 m³/h! This is the result of a large project carried out by Grundfos Alldos for the city of Istanbul together with Durko as the local representative.The background: the municipal waterworks of the Turkish metropolis draw their raw water from a local lake. The water is routed from there to the various waterworks for treatment.To enable problem-free ...


  • Groundwater Plume, Source and Risk Identification Using Passive Soil Gas

    Abstract The results from sixty passive soil gas (PSG) samplers placed at a grain silo and mixed-use industrial facility with a known chlorinated solvent release aided with the rapid investigation time-schedule. The samplers were used to determine potential sources, plume extent and vapor risks in areas beyond the previous discrete soil sampling and permanent groundwater monitoring well ...

  • Chloroflourocarbon (CFC) remediation case study

    Project Description The Site location was an industrial facility located in the greater South Los Angeles region that manufactured chemicals for local petrochemical and other industrial operations from 1919 through late 1990’s. Refrigerants were initially produced in 1964 including chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) such as trichlorofluoromethane (R-11), ...

  • Chemical Mass Transport Measurements to Determine Flexible Membrane Liner Lifetime

    The prediction of the service life of flexible membrane liners (FMLs) when exposed to chemicals has usually been by way of testing for physical or mechanical property changes after periodic exposure times. This paper presents an alternate approach by evaluating the chemical properties via five different mass transport related measurements of the exposed FML. These tests are water vapor ...


    By ASTM International

  • Case Study - TCE Source Area Remediation at a Former Manufacturing Facility Confidential Client – Western Connecticut

    Project Summary TRS Group, Inc. (TRS), as a subcontractor to AECOM, completed a Standard Fixed Price Remediation (SFPR) of trichloroethene (TCE) in groundwater in Western Connecticut using Electrical Resistance Heating (ERH). The objective of the ERH project was to achieve the prescribed remediation goal for dissolved TCE in groundwater within the treatment volume. The system ...


    By TRS Group, Inc.

  • New Advancements for In Situ Treatment Using Electrical Resistance Heating

    Electrical resistance heating (ERH) is proving to be an effective technology to rapidly heat the subsurface and, in doing so, removing volatile organic compounds. Practitioners of this technology have observed that other processes (biodegradation, abiotic degradation, hydrolysis, and possibly others) occur to break down the chemicals of concern, and remediation is not solely accomplished through ...


    By TRS Group, Inc.

  • Full-scale SVE system operates in tandem with groundwater treatment

    Since 1993, SVE has been implemented using two designs at the TP Industrial, Inc. (TPI) site in Gardena, CA, to treat soil contaminated with chlorinated solvents. The SVE system was modified in 1997 to improve emissions control efficiency by using carbon adsorption units that treat effluent from an air-stripping system for treating site ground water. By the end of 2007, SVE had removed a ...

  • Tacoma, Washington - Well 12A superfund site - Case Study

    Combined Remedies for DNAPL Remediation Project Summary TRS Group, Inc. (TRS) teamed with KEMRON and AMEC, under KEMRON's U.S. Army Corps of Engineers (USAGE) Environmental Remediation Services Multiple Award Task Order Contract (MATOC), to perform electrical resistance heating (ERH) for the remediation of volatile organic compounds (VOCs) in the vadose zone ...


    By TRS Group, Inc.

  • Electronics Manufacturing Industry - Pollution Prevention Guidelines

    Introduction Pollution Prevention Guidelines to provide technical advice and guidance to staff and consultants involved in pollution-related projects. The guidelines represent state-of-the-art thinking on how to reduce pollution emissions from the production process. In many cases, the guidelines provide numerical targets for reducing pollution, as well as maximum emissions levels that are ...


    By The World Bank

  • In situ Remediation of 1,4-Dioxane using Electrical Resistance Heating

    An increasing number of states are establishing enforceable 1,4-dioxane cleanup goals due to recent improvements in analytical detection methods and existing carcinogenic risk information for 1,4-dioxane. Historically, 1,4-dioxane was used as a stabilizer for chlorinated solvents, primarily 1,1,1-trichloroethane. In addition, 1,4-dioxane has been used in a broad range of products including but ...


    By TRS Group, Inc.

  • EPA Technology News & Trends - Tacoma “Well 12A” Superfund Site

    The U.S. EPA Region 10 office uses an adaptive site management approach that relies on high-resolution site characterization (HRSC) techniques for strategic sampling at the Well 12A project area. This approximate one-square-mile project area is one of three at the 2.5-square-mile Commencement Bay-South Tacoma Channel Superfund site in Tacoma, Washington. The vicinity of Well 12A, one of 13 wells ...


    By TRS Group, Inc.

  • Foundries Industry - Pollution Prevention Guidelines

    Introduction Pollution Prevention Guidelines to provide technical advice and guidance to staff and consultants involved in pollution-related projects. The guidelines represent state-of-the-art thinking on how to reduce pollution emissions from the production process. In many cases, the guidelines provide numerical targets for reducing pollution, as well as maximum ...


    By The World Bank

  • Bioventing

    Introduction Bioventing is a promising new technology that stimulates the natural in situ biodegradation of any aerobically degradable compounds in soil by providing oxygen to existing soil microorganisms. In contrast to soil vapor vacuum extraction, bioventing uses low air flow rates to provide only enough oxygen to sustain microbial activity. Oxygen is most commonly supplied through direct air ...

  • Introduction to Ozone Injection Technology

    Untitled Document Ozone is a highly reactive chemical that has proven to be effective in destroying a wide variety of organic chemicals, including MtBE and chlorinated VOCs. ...

  • Fixed Versus Portable Gas Detection – Which Is Better?

    Did you know that workers are needlessly injured every year as a result of leaking toxic or combustible substances? Such incidents are known to involve a wide range of hazardous gases (including ammonia, carbon monoxide, chlorine, hydrogen sulfide, hydrocarbon vapors and so on). The sad reality is that most of these accidents are avoidable if only the workplace is adequately monitored. This leads ...

  • Methods of Water Purification

    This article is excerpted from 'Pure Water Handbook' published by Osmonics®, Inc. of Minnetonka, Minnesota USA and is printed with permission of Osmonics, Inc. Water treatment can be defined as any procedure or method used to alter the chemical composition or natural 'behavior' of a water supply. Water supplies are classified as either surface water or groundwater. The majority of public or ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you