combustion analyzer Articles

  • Introducing LaserGas III SP CO – a combustion analyzer for rough environments

    NEO Monitors unveils the industry’s most compact CO combustion analyzer suitable for the most demanding environments. LaserGas III CO includes measurement of CH4, H2O and temperature in one single unit designed to reduce risk. Based on decades of experience and customer feedback, NEO Monitors has designed an Ex-d certified tunable diode laser (TDLS) analyzer. The instrument is ...


    By NEO Monitors AS

  • TOC Analysis for Standard Methods 5310B: High-Temperature Combustion Method

    Introduction Total Organic Carbon (TOC) is a rapid method that analyzes for organic carbon and expresses the result as the amount of carbon found. It is a non-specific method unable to distinguish between various organic species and only indicates that organic carbon compounds are present. Organic carbon analyzers operate by the determination of the amount of total carbon present in a ...

  • Application of combustion analyzers in safety instrumented systems

    The combustion process has always been considered having the potential for a hazardous event which could lead to personnel injury or loss of production. To mitigate this risk, the process industry is now implementing Safety Instrumented Systems which can identify hazardous operating conditions and correctly respond in such a way to bring the combustion process back to a safe operating condition ...

  • AMETEK THERMOX Introduces the WDG-V Combustion Analyzer

    Abstract AMETEK THERMOX Introduces the 5th Generation THERMOX Combustion Gas Analyzer in a CONTROL Magazine Exclusive. WDG analyzers are based on a zirconium oxide cell that provides a reliable and cost-effective solution for measuring excess oxygen in flue gas as well as CO and methane levels.  Information from the Gas Analyzer allows operators to obtain the highest ...

  • Wind Energy Production Estimates: Moving Beyond Time Averages

    No need to be a statistician to see that averages are often useful to compare different things. And yet, they often fall short as a true measure of performance. For instance, we use averages to compare the current weather against the climate normals or to get a sense of how our favorite sport team or player is doing. Team (player) statistics are a concise way of combining the scores from many ...


    By AWS Truepower, LLC

  • 5th-Generation Thermox WDG Flue Gas Combustion Analyzer

    "For more than 40 years, we have been a leader in combustion gas analysis," says Mike Fuller, divison VP of sales and marketing and business development for Ametek Process Instruments, "and we believe the WDG-V is the combustion analyzer of the future." WDG analyzers are based on a zirconium oxide cell that provides a reliable and cost-effective solution for measuring excess oxygen in flue gas as ...

  • Forklift Emissions Analyzers

    Forklifts are commonly used in warehouses of various size and capacity for the movement and shipping of goods; however, the unoptimized engines can produce excess quantities of silent and deadly CO gas that can risk the health and safety of the workers. When forklifts are brought in for service usually the CO gas isn't measured. If the CO gas isn't measured and the engine properly optimized then ...

  • Catalytic Exhaust Emission Control of Small Internal Combustion Engines

    ABSTRACT Gaseous emissions present in the engine exhaust of on-road motor vehicles are subject to stringent exhaust emission 2ontrol standards for carbon monoxide (CO), hydrocarbons, and ...


    By DCL International Inc.

  • FTIR resolution requirements for industrial gas analyzers

    FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epi-treatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D facilities, FTIR is applied to combustion thermodynamics and stack gas emissions; ...


    By CIC Photonics, Inc.

  • FTIR resolution requirements for industrial gas analyzers

    FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epi-treatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D facilities, FTIR is applied to combustion thermodynamics and stack gas emissions; ...


    By CIC Photonics, Inc.

  • Case study: TOC recovery studies comparing combustion/NDIR with UV-persulfate/membrane conductometric methods for municipal raw and finished drinking water monitoring

    Objective Numerous studies have been conducted to compare the performance of various TOC methodologies on a wide range of raw source water and finished drinking water samples. The methodologies studied are those that are approved for TOC monitoring under the USEPA’s Disinfectants and Disinfection Byproducts Rule (D/DBPR). The results of these studies demonstrate that ...


    By GE Analytical Instruments

  • Comparative Evaluation of Test Methods for Reciprocating Engines; EPA Reference Methods vs. Portable Analyzer

    Abstract This is a comparative evaluation of errors in testing engines using reference methods and portable analyzers. New Mexico Environment Department (NMED) Air Quality Bureau has published a guidance document, Standard Operating Procedure (SOP), Use of Portable Analyzers in Performance Tests. EPA provides guidance on reference method testing in 40 CFR 60, Appendix A. This document is ...


    By Trinity Consultants

  • PureAire Oxygen Analyzer for 3D Printers: How Argon is used and Why O2 Detection is Required

    Thanks to new technologies, the 3D printers that have been used to create plastic three-dimensional objects can now print metal. Titanium 3D printing is possible thanks to a technique called DMLS, or Direct Metal Laser Sintering. While the potential to use titanium 3D printing is groundbreaking for many industries, the new advances could pose a health hazard if volatile gases used in the printing ...

  • Overview of ECO PHYSICS Products and Markets

    ECO PHYSICS AG manufacturers a wide variety of chemiluminescence NOx analyzers for industry, combustion research, atmospheric research and medical research. A look at our markets and products gives an impression of our ...


    By ECO PHYSICS INC.

  • New Green Methodology for Measuring Total Organic Carbon (TOC) — Supercritical Water Oxidation (SCWO)

    Analyzing the total organic carbon (TOC) content of industrial wastewater, process influent and effluent water, and environmental water samples can be very challenging. These aggressive sample matrices often clog or damage TOC analyzers that use the combustion method. This can result in expensive preventive maintenance and excessive non-regenerative waste. To address these critical issues, GE ...


    By GE Analytical Instruments

  • Measurement of TOC in High-Salt Sample

    The quantity of organic matter in seawater is important in the research and monitoring of marine pollution as an indicator of organic pollution. The salt content in seawater is typically about 3.5 %, but using the Shimadzu total organic carbon analyzer, it is possible to measure the TOC directly without dilution or other pretreatment procedures. Here, we introduce an example of measurement of ...

  • Measurement of TOC in Perfluorochemical (PFOS) Solution

    PFOS is an extremely stable compound with strong carbon - fluorine bonds, and reports of its accumulation in wildlife and the environment have attracted international attention and concern, leading to the designation of PFOS as a persistent organic pollutant (POP).The persistent nature of PFOS prevents oxidative decomposition using wet chemical oxidation TOC analyzers; however, the Shimadzu ...

  • The Other Side of Zirconium Oxide case study

    Regular Fuel Efficiency Applications Separate Oxygen and Combustibles Sensors In standard flue gas applications for Thermox analyzers, the user generally tries to extract the maximum energy from the fuel and transfers as much of that energy as possible to the process. These applications require the process to be operated as efficiently as possible by keeping both oxygen (excess air) and ...

  • TOC System Suitability Test for Sterile Water

    The United States Pharmacopeia (USP) specifies that total organic carbon (TOC) content be used for management of organic impurity values permitted in bulk purified water, water for injection, in addition to sterile purified water and sterile water for injection. According to USP, TOC analyzers to be used for sterile water must satisfy the TOC system suitability test using test water ...

  • Comparison of Impinger and Canister Methods for the Determination of Siloxanes in Air

    Abstract Tliis paper compares canister and impinger methods for the analysis of siloxanes in air by gas chromatography/inass spectrometry (GC/MS). Siloxanes are frequently found in commercial and consume? products such as detergents and cosmetics. Most low molecular weight siloxane compounds volatize quickly into the atmosphere; however, some end up in wastewater or landfills when consumer ...


    By Eurofins Air Toxics Inc

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you