combustion control analyser Articles

  • High temperature combustion of landfill gas

    Type     Compact plant HOFGAS® - Efficiency 250 Commissioning     December 2001 Site     Storkohmo landfill, Kokkola (FIN) Situation Storkohmo landfill is located 400km north of Helsinki on Finland's west coast near the city of Kokkola. Based on local legislation requirements ( reduction of green house gas emissions ) the ...


    By Hofstetter BV

  • Analysing coloured smoke | Pearl or Quest?

    Coloured smoke consists of an aerosol of tiny particles which is combusted or vaporized. The particular pigment or dye of each colour affects the colour of the smoke. The mixture usually includes a cool-burning formula based on potassium chlorate oxidiser, dextrin or lactose as fuel. Then one or more dyes are introduced to account for around half of the mixture. A small amount of sodium ...


    By Specac Limited

  • Emissions analyser helps manage power station

    A multiparameter emissions monitor at Thetford power station is being used to demonstrate to the Environment Agency that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Milton Keynes based Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are ...


    By Quantitech Ltd

  • FTIR emissions analyser helps manage UK power station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Quantitech Ltd

  • FTIR Emissions Analyser helps manage UK Power Station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Gasmet Technologies Oy

  • Real-time TOC tightens effluent control at Greencore

    A food manufacturing facility in Selby has installed a new continuous TOC (Total Organic Carbon) monitor, ‘the BioTector’ which has dramatically improved the site’s capability to refine and improve the plant’s wastewater treatment process. As a result the plant is better able to quickly respond to changes in the influent. Greencore Foods is a leading player in the food ...


  • Gas Monitoring for Ventilation Control and Energy Management

    The growing demand for underground and enclosed parking and maintenance garages (resulting from limitations on land availability) has increased the awareness and need for proper ventilation and control systems. In addition, increased health and safety programs have only added to the concerns of toxic and combustible gases in confined or enclosed spaces. Historically, ventilation and make-up air ...


    By Arjay Engineering Ltd.

  • Gas boiler load optimisation controls can rectify dry cycling and reduce energy costs by 25%

    Dry cycling of gas boilers can waste a great deal of energy, even when BMS optimisation is in use. Installing gas boiler load optimisation controls can reduce this waste and help boilers run more efficientlyBuilding engineers, energy and facilities managers tend to overlook that many gas boilers waste energy through dry cycling when they are not actively contributing to the building heating and ...


    By Vital Efficienci Ltd.

  • Cumulative exergetic assessment of LPFO utilised steam boilers

    This paper relates to a study on the energy and exergy resources, transfers, consumption and losses in the combustion and heat exchanging units of industrial steam boilers. Mass, energy and exergy analyses, which included the physical and chemical exergies of material streams, were used to investigate the energy resource utilisation of Low Pour Fuel Oil (LPFO) in industrial steam boilers. The ...


    By Inderscience Publishers

  • Fuel reduction potential of energy management for vehicular electric power systems

    In the near future a significant increase in electric power consumption in vehicles is to be expected. To limit the associated increase in fuel consumption and exhaust emissions, smart strategies for the generation, storage/retrieval, distribution and consumption of the electric power can be used. This paper considers a vehicle configuration with a conventional drive train. Two energy management ...


    By Inderscience Publishers

  • Online analysis of TOC, TNb, TP, and COD in water

    The control of waste water treatment plants is of special importance - from an ecological as well as economic point of view. The most common water parameters for controlling and optimization are the total organic carbon (TOC), chemical oxygen demand (COD), total nitrogen bound ( ...


    By LAR Process Analysers AG

  • Energy conservation studies on residential heating systems: an application for Izmir, Turkey

    Energy conservation through improvement of the efficiencies of end use devices such as boilers and stoves used for space heating is one of the most effective ways to provide immediate relief for the energy problem in the residential sector of Turkey. For this reason, during the 1995-96 winter period, the campaign "Saving the Environment Begins at Home" was launched by the branch office of the ...


    By Inderscience Publishers

  • Reliable silica monitoring supports power station efficiency

    West Burton B CCGT is a Combined Cycle Gas Turbine power station near Nottingham in the UK. It has three open-cycle gas turbines capable of generating enough electricity for approximately 1.5 million UK homes. In common with all combustion based power stations, the CCGT has a requirement to monitor silica levels in the Plant’s water and steam processes. Sean Todd, the Plant’s Control ...

  • FTIR gas monitor for diverse applications

    QUANTITECH, a leading supplier of environmental monitoring instrumentation, has recently supplied EURO Environmental Services in Ireland with a transportable Gasmet FTIR multiparameter gas analyser which EURO Environmental's Managing Director Geoff Fitzpatrick says, “is proving invaluable in many varied applications across a broad selection of industries.” With headquarters in Drogheda in Ireland ...


    By Quantitech Ltd

  • Methanol blending is alternative fuel of the future

    The main objective of “alcohol fuel power” field is increase of fuel resources for transport by using right alternative  such as ethanol and methanol blending with gasoline, which unlike pure oil fuel, are characterized renewable and have unlimited sources of raw materials. Margin of oil (valuable hydrocarbonic raw materials for petrochemical productions) and also a power ...


    By GlobeCore Blending

  • Xp3 Fuel Efficiency and Maintenance Case Study by Pepsi Guatemala

    PEPSI Guatemala Fuel: Diesel Machine/Type: Truck/Motor Test: Fuel Efficiency and Maintenance OBJECTIVE Evaluation of Xp³ for Diesel’s effectiveness in transport units Nos. 950 y 945. Fuel consumption history, oil analysis, and injectors were checked before Xp³ was added. Oil analyses were conducted after 5,352 km, with and without Xp³. In addition, a detail record of ...


    By Xp3 Canada

  • Fixed Versus Portable Gas Detection – Which Is Better?

    Did you know that workers are needlessly injured every year as a result of leaking toxic or combustible substances? Such incidents are known to involve a wide range of hazardous gases (including ammonia, carbon monoxide, chlorine, hydrogen sulfide, hydrocarbon vapors and so on). The sad reality is that most of these accidents are avoidable if only the workplace is adequately monitored. This leads ...

  • Impact of selected policy measures on Europe`s air quality

    This report was prepared by the European Topic Centre for Air and Climate Change (ETC/ACC) of the European Environment Agency (EEA). The authors of the report were Jeroen Kuenen, Mtinkheni Gondwe, Tinus Pulles (TNO, the Netherlands), Frank de Leeuw (PBL, the Netherlands) and Justin Goodwin (S-ESC, United Kingdom). The EEA project manager was Martin Adams. Dr. Leonidas Ntziachristos (Aristotle ...

  • New gas calibration method eases TOC analysis

    LAR Process Analysers AG of Berlin,  Germany expanded the range of feaiures of its measuring device QuickTOC, which facilitates the monitoring of ultra pure and cooling water, boiler feed and condensate measurement, and industrial wastewaters. For many years, the Berlin company lias been developing, high quality measuring devices and processes for the TOC analysis of condensates and boiler ...


    By LAR Process Analysers AG

  • What is Intrinsic safety and ATEX?

    What is intrinsic safety? Intrinsic safety (IS) is a low energy signalling technique that ensures the safe operation of electrical equipment in hazardous areas by limiting the energy – both electrical and thermal – available for ignition. ...


    By Hansford Sensors