concrete floor decontamination Articles

  • Surface Decontamination of Iodine (Potassium Iodide (KI)) by DeconGel®

    OBJECTIVE: Determine the surface decontamination efficacy of DeconGel® 1101 on stainless steel, carbon steel, floor tile, and concrete surfaces contaminated with potassium iodide (KI) using ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) following ...


    By METIS Scientific

  • R1-348 decontamination @ Ontario power generation

    RP checked and after several masslins left area and posted 5,000 cpm loose Extensive Decontam in this area attempted due to > 10,000 cpm loose, masslins and wet mopping Applying Decon Gel Gel applied 3” up the wall Lesson –tape edge and ensure adequate thickness Drain covered with tape  Peeling up ...


    By METIS Scientific

  • Surface Decontamination of Iodine Compounds (Potassium Iodide (KI)) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on stainless steel, carbon steel, floor tile, and concrete surfaces contaminated with potassium iodide (Kl) was performed with ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) according to Environmental Protection Agency (EPA) SW-846 Methods: 3005A (sampling) and 6010C (analysis). ...


    By METIS Scientific

  • Surface Decontamination of Halogenated Solvents (Tetrachloroethylene) by DeconGel 1101 and 1102

    Abstract Surface decontamination efficacy determination of DeconGelTM 1101 and 1102 on stainless steel, floor tile, and concrete surfaces contaminated with halogenated solvents (tetrachloroethylene (TCE)) was performed with LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling) and 8321B (analysis). ...


    By METIS Scientific

  • Surface Decontamination of Aromatic Liquids (Toluene) by DeconGel 1101 and 1102

    Abstract Surface decontamination efficacy determination of DeconGelTM 1101 and 1102 on stainless steel, floor tile, and concrete surfaces contaminated with aromatic liquids (toluene) was performed using LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling) and 8321B (analysis). Hazardous ...


    By METIS Scientific

  • Demonstration of DeconGel at Oak Ridge National Laboratory building 2026

    Challenge In 2003 an area behind the hot cells in Building 2026 at the Oak Ridge National Laboratory (ORNL) was flooded with highly contaminated liquids when a liquid low level waste pipe became clogged. The main contaminants of concern are uranium and plutonium. Transferrable contamination levels are in the 1,000,000 disintegrations per minute range. The area is posted as an airborne ...


    By METIS Scientific

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you