corrosive gas monitoring Articles

  • Effective Temperature Control for Cement Kiln Off-Gases

    INTRODUCTIONEffective off-gas temperature control without unwanted side effects can be achieved in many cement plants with state-of-the-art evaporative spray technology. Gas temperatures have elevated in recent years from as low as 180°C to over 370°C. This is coincident with a higher proportion of 'dry' operation kilns. Evaporative cooling water sprays in conditioning towers, ducts or at the ...


  • Checklist for Boiler Maintenance

    Boilers play a crucial role at industrial facilities and it is imperative that they be safely and properly maintained. Routine boiler maintenance can help prevent unplanned shutdowns and outages, increase the efficiency of the boiler and cut operating costs, and ensure that the facility is in full compliance with all laws and regulations governing boiler safety. What follows is a boiler ...


    By STI Group, Inc.

  • Five of the Best Cooling Tower Water Treatment Equipment Supply and Technology Companies

    Here at SAMCO technologies, our custom-engineered, cutting-edge solutions for your cooling tower water treatment needs have been developed by helping our customers solve some of the most complex purity and separation issues globally for over 40 years. Because of our skilled engineers and overall expertise in cooling tower water treatment, we are confident that our solutions are some of the best ...


    By SAMCO Technologies, Inc.

  • Wastewater-Solids Dewatering Odor Control - Case Study

    Background The Milan Wastewater Treatment Plant, located just south of Moline, Illinois, is a 1.7 MGD (6,434 m3/day) activated sludge facility with an average wastewater flow of 700,000 gpd to 800,000 gpd. This facility dewaters primary sludge using a belt filter press (Figure 1). The press operates an average of three times per month, 8 hours per day at a pump rate of 100 gpm. The ...


    By Carus Corporation

  • Chemical Industry: HCL System Exceeds Current Regulations Emission control meets requirements while recovering by-product for sale Case Study

    Chemron manufactures high-quality specialty chemicals and surfactants for personal care products, industrial, institutional, oil field, mining, coatings, lubricants and water treatment. Some of the operations result in the creation of hydrochloric acid with high variable rates. As expressed by Bill Frost, of Chemron: “Chemron maintains a strong environmental commitment, which views ...


    By CR Clean Air Group, LLC

  • Pushing the Limits of Reengineering

    Cutting-edge turbine technology enables more efficient and cleaner power generation. However, the service of advanced gas turbines is challenging—especially when parts need to be replaced. The example of a blade replacement project shows how Sulzer establishes innovative reengineering processes and contributes to a secure energy supply that causes less carbon emission. A Sulzer ...


    By Sulzer

  • How to Save with Cooling Tower Credits

    Cooling towers dissipate heat from recirculating water used to cool chillers, air conditioners, or other process equipment to the ambient air. Heat is rejected to the environment from cooling towers through the process of evaporation. Therefore, by design, cooling towers use significant amounts of water. The thermal efficiency and longevity of the cooling tower and equipment depend on the proper ...


    By WaterSignal

  • City Of North Bay Uses Condition Assessment On Critical Force Main To Implement Asset Management Plan

    On one hand, it may seem like a waste of capital dollars if you perform a pipeline condition assessment and the final analysis turns up no leaks. Alternatively, you can also look at the no-leak report as a good news validation story, especially when using the information to help establish an asset management ...


    By Pure Technologies

  • Case study - Washington Suburban Sanitary Commission

    After WSSC began experiencing major PCCP failures in the 1970s, it developed a strong commitment to infrastructure management technology in favor of large capital replacements. Beginning in 2007, WSSC and Pure Technologies began a partnership to create a comprehensive PCCP management program. The Washington Suburban Sanitary Commission (WSSC) is the 8th largest water and wastewater utility in ...


    By Pure Technologies

  • Is your Plant as tight as you think? Leak Detector for extremely toxic Gases, a Field Test Report

    Leak detection of commodity gases in chemical plants is a day-to-day practice. The sensor technology available for this application is field proven and reliable. No question about it, existing sensors will do the job. However, in plants manufacturing or handling extremely toxic substances, the picture is different. For example, take phosgene. The existing sensor technology for leak detection ...

  • Cost Effective, Easy to Operate H2S Removal in Central China

    Documento sin título In 2000, ...


    By Merichem Company

  • Controlling Stack Emissions in the Wood Products Industry

    Electrostatic precipitation has been a reliable technology since the early 1900's. Originally developed to abate serious smoke nuisances, the manufacturers of zinc, copper, and lead quickly found electric gas cleaning a cost efficient way to recover valuable product carried out of the stacks from furnace operations. Today electrostatic precipitators are found mainly on large power plants, cement ...


  • Taking Fossil Fuels to the Next Level - Standards Underpin Extraction, Processing and Distribution

    To the average person, the oil and gas industry may appear simple — a matter of literally tapping into a natural resource and distributing it to customers. Of course the matter of extraction is rarely simple, and in the case of emergent hydraulic fracturing technology, it is particularly complex and capital-intensive. In fact, the world of petroleum and natural gas extraction, distribution ...


    By ASTM International

  • Cerex introduces the new AirSentry FTIR Open Path Analyzer

    Cerex Monitoring Solutions is pleased to announce the release of the third generation model AirSentry FTIR multi-gas open path FTIR analyzer. The decision was made to fully redesign the analyzer to take full advantage of advances in hardware and software technology. The third generation design represents a full reconfiguration of the instrument. Goals were to reduce initial and operating costs ...

  • Hospital laundry’s energy and water costs tumble and CO2 emissions fall after fitting GEM steam traps

    Dedicated to taking an active role in reducing its carbon emissions as well as saving costs, MTW Linen Services, a subsidiary of Maidstone & Tunbridge Wells NHS, has reduced its CO2 emissions by 12.5% following the installation of Thermal Energy International’s GEM venturi orifice steam traps.  In addition, the laundry has reduced its energy consumption by 12% and its water usage ...

  • Nitrogen Dioxide Testing in Indoor Environments Protects Human Health

    During the winter months, when homes and businesses typically have their windows and doors closed, can result in an increase in indoor air quality (IAQ) complaints.  In addition to a lack of fresh air in many buildings during this time, problems due to gases not properly vented from heaters frequently occur.   Nitrogen oxides can be of increased concern during these cold winter ...

  • Corus installs gem steam traps to improve energy conservation and reduce co2 emissions

    Corus’s Trostre Steel Works in Llanelli, South Wales has installed Thermal Energy International’s GEM Venturi orifice steam traps as part of the plant’s continuous improvement programme into energy conservation and CO2 reduction.  A leading supplier of high quality light gauge steels, the site produces over 400,000 tonnes a year of packaging steels for the UK market. As ...

  • Case study - Bi-On Carb OX: Odor treatment in WWTPs. Case study SIMTEJO (Portugal)

    Avoiding problems associated with foul odors in and around collectors and waste water treatment plants is today one of the major focus points to avoid possible issues related to worker safety, as well as minimizing negative social discomforts caused by the foul odors. The main sources that generate foul odors in WWTPs occur at stages of anaerobiosis, where the lack of oxygen favours the ...


    By Bioconservacion SA

  • Mixed Oxidant Replaces “Cocktail” of Chemicals in Power Plan

    Cooling Tower Water Systes Synopsis In 2010 NIPSCO installed two MIOX RIO Mixed Oxidant Solution (MOS) chlorine generator systems on two of the four cooling towers at R.M. Schahfer Generating Station.  After switching to MIOX for cooling tower water treatment, the two towers experienced minimized algae growth, better biocontrol and lower Legionella counts, ...

  • Hydrogen Sulfide Analyzers – Finding the Right Fit for Your Needs

    Monitoring hydrogen sulfide (H2S) levels is critical for air quality, safety and environmental professionals across a multitude of industries. Doing so helps prevent complaints, citations, penalties, corrosion, fires, illness, and even death. ...


    By Arizona Instrument LLC

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you