digester equipment Articles

  • Equipping Digester For Feedstock Flexibility

    Bayview Flowers is a high value, greenhouse floriculture operation in Jordan Station, Ontario, Canada, that supplies wholesalers and retailers across North America. In 2007, the company installed an anaerobic digester (AD) plant to generate 250 kW of renewable energy. The system was installed to take advantage of a province-wide Feed-In-Tariff (FIT) incentive program to increase the amount of ...


    By BioCycle Magazine

  • Case study - Procurement and installation of a Biogas desulphurization unit at the Chania WWTP

    A proposal based on Bioconservacion’s technology was selected as the winning bid in the public tender released in 2015, covering the design, procurement and construction of a biogas desulfurizing unit to be installed in the waste water treatment plant in Chania, Greece. With a population over 100,000, Chania is the second largest municipality in the Greek island of Crete. Its waste water ...


    By Bioconservacion SA

  • Tax Credit Tips For Biogas Projects

    With the end of 2016 in plain view, anaerobic digestion (AD) projects in the development phase should examine what has to happen by December 31 in order to tap into available federal tax credits. Under current law, Section 45 of the federal tax code makes AD projects eligible for a Production Tax Credit (PTC), which can be converted into an Investment Tax Credit (ITC), if the projects are used to ...


    By BioCycle Magazine

  • Reduced Emissions for Landfill Gas Installations

    The use of landfill gas as a source of renewable energy is increasing. For environmental and safety reasons, the owners of the waste storage sites have to strictly monitor and control the construction, operations, and emissions generated. Sulzer offers solutions to control these emissions within the limits given by the government. Landfill gas is similar to natural gas, but it is created by ...


    By Sulzer

  • Innovation Key To Biosolids Digestion

    A $400 million project at the Blue Plains Advanced Wastewater Treatment Plant (AWTP) in Washington, D.C., involves building an innovative biosolids management system comprised of a thermal hydrolysis process, four 3.8-million gallon mesophilic digesters (measuring 70-ft tall by 100-ft in diameter) with fixed covers, a cogeneration system consisting of three 4.6-MW Solar Mercu ry 50 gas turbines ...


    By BioCycle Magazine

  • Golf and a Small Anaerobic Digester

    Golf course associations and golf clubs around the world are looking at ways to improve the sport’s environmental criteria.  Sustainable developments and low carbon footprint operations are the name of the game.  As golf courses use fertiliser for the courses, power for the maintenance machinery, and power for the golf carts, there are many areas where sustainability of the sport ...


    By SEaB Energy Ltd.

  • Aerators Enhance Aerobic Digestion Process

    The city of Eden,N.C.,operates an extended aeration process designed for an average flow rate of 13.5 mgd with a mixed liquor suspended solids concentration that typically checks in about 6,000 mg/l. This high biomass concentration is necessary to provide a well-settling sludge and good effluent quality. Further, the plant influent is approximately 40% domestic wastewater and 60% industrial ...


    By S & N Airoflo, Inc.

  • Case study - Sludge digestion/thickening optimizes treatment

    Overview: Big Park Domestic Wastewater Improvements District in Arizona had constructed a new 500,000 gallons per day biological wastewater treatment system in 1997. As time passed, the aging plant was unable to keep up with increasing demands. Challenge: In 2012, the District started working with Sunrise ...

  • New processes for the improvement of sludge digestion and sludge dewatering

    INTRODUCTIONThe examination of numerous sewage sludges from municipal wastewater treatment plants leads to the conclusion that on the one hand dewaterability of these sludges worsens and that on the other hand dewaterability of sludges becomes more and more important due to increasing disposal costs. Especially wastewater treatment plants with inflows from the food processing industry often face ...


    By Cambi AS

  • Digester Developers Target Mixed Organic Waste Streams

     emerging group of commercial companies see a viable business opportunity in North America around building, owning and operating larger scale anaerobic digestion (AD) facilities to process mixed organic waste streams. In some instances, the projects being proposed and constructed only include anaerobic digester operations. In others, there is a combination of digestion with back-end ...


    By BioCycle Magazine

  • The effect of mixing conditions on anaerobic digester performance

    The basic principle of aerobic wastewater treatment is the conversion of some parts of organic matters to biomass and this causes production of excessive sludge in aerobic processes. This excessive sludge is withdrawn from time to time to prevent accumulation of biomass in aeration basin. In most cases, this sludge requires the stabilization before the dewatering and disposal. Different processes ...


    By ORBIT e.V.

  • Digester Developer Taps Natural Gas Markets

    IN the late 1990s, Dan Eastman and two colleagues were researching business opportunities in the renewable energy industry. They were looking for a commercially viable technology that could take renewable energy from an experimental phase to a solid business investment. In 1999, Eastman and his partners founded Microgy, Inc., with its base in Wisconsin. The company licensed the Xergi anaerobic ...


    By BioCycle Magazine

  • Molecular Chemical Grinder Improves Digestion in Sludge

    Municipal wastewater treatment plants (WWTPs) can reduce the costs and liabilities of sludge handling and disposal and increase their organic solids conversion rate with the Advanced Fluidized Composting (AFC) Process or the Advanced Fluidized Co-Digeson & Co-Generaon (AFC2) Process from BioConversion Soluons, LLC (BCS). The conventional sludge treatment techniques of aerobic and anaerobic ...

  • Combined experiences of thermal hydrolysis and anaerobic digestion – latest thinking on thermal hydrolysis of secondary sludge only for optimum dewatering and digestion.

    ABSTRACT The basic principles of batch thermal hydrolysis process (THP) are well known as a pre-treatment to anaerobic digestion (AD) . Early work done in the 70s in the USA and the 80s in Japan demonstrated the optimum time and temperature for thermal hydrolysis being 340 F for 30minutes. These principles have been put into full practice in 20 plants around the world at plants ranging from 5 ...


    By Cambi AS

  • Two-phase anaerobic digestion for class a biosolids at moccasin bend WWTP

    The Moccasin Bend Wastewater Treatment Plant (WWTP) provides treatment for the City of Chattanooga, Tennessee and the surrounding region. The City has completed upgrades to the solids handling facilities to treat and dewater the primary solids and waste activated sludge (WAS) from the WWTP. This paper summarizes the process to handle the primary solids and the start-up process. Primary solids ...

  • Manure Spills: Prevention, Detection, Control Options, & the Role of Anaerobic Digesters

    An internet search for manure-related spills can lead to an exhausting list of news articles and images of catastrophic environmental damage. In Wisconsin alone, the ...


    By BIOFerm™ Energy Systems

  • Optimising thermal hydrolysis for reliable high digester solids loading and performance

    Chertsey (Thames Water) Cambi thermal hydrolysis was refurbished during the early part of 2005 and started operation in August 2005 under a separate contract to Cambi operations.  The plant has run continuously since that time except for planned shut downs (inspection and Christmas day) with 2 hours of unplanned shut down.  Initially it was envisaged the plant would achieve an average ...


    By Cambi AS

  • Digester gas - countess wear sewage treatment works - case study

    South West Water leads the way with highly efficient biogas combined heat and power Technology, utilising otherwise harmful digester gas. South West Water (SWW) provides clean water and sewerage services to over 1.6 million people, 365 days a year. Dedicated to environment and conservation issues, SWW is committed to using energy efficient Combined Heat and Power (CHP) generation systems. SWW has ...


    By ENER-G

  • The Cambi Thermal Hydrolysis Process (THP) – dramatically improving sludge digestion and dewatering

    CAMBI MILESTONES 1990 - First development work following research work of Li and Noike 1995 – HIAS Norway – first full scale plant – still working very well after 11 years 1998 - 2002 rapid increase in projects, Denmark, England, Norway, Scotland, Japan, Ireland – new challenges and risks to be overcome 2000 - 2005 some problem solving ...


    By Cambi AS

  • Comparison of centrifuge and belt press for compressible digested sludge after thermal hydrolysis

    Abstract Historically it has been shown on many projects that centrifuges can outperform belt presses in dewatering digested sludge. However, results from a number of projects where sludege has been treated before digestion with Cambi thermal hydrolysis process (THP) hase shown good results for belt press dewatering - generally greater than 30% DS. The authors propose that the main mechanism in ...


    By Cambi AS

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you