digital flow meter Articles

  • Development of a self-rechargeable digital water flow meter

    The objective of this paper is to present the feasibility of a self-rechargeable digital water flow meter (SRDFM) system for water pipes using the latest data processing and wireless communication technologies while causing negligible water pressure drop (head loss). The system uses a Pelton turbine generator to power the electronic circuit, which processes and transmits the signals generated by ...


    By IWA Publishing

  • Portable Hydrant Flow Meters

    Leading the way for hydrant verification flow and pressure measurement Langham Industrial Controls strive to provide the most innovative market leading hydrant verification instrumentation. The Horizontal Standpipe Flow Meter provides unrivalled accuracy of ± 0.5% within a wide flow range. The swan neck design ensures that the AquaMasters electromagnetic sensor is always full and as the ...

  • Flowmeter Portable Handhold Ultrasonic Flow Meter

    The Technologists from A.YITE Electronic(America) Laboratory, have done much efforts to design portable ultrasonic flowmeter, we would like to supply suitable measurement for the travelling engineer.  There is no moving part in the EU-109H ultrasonic instrument, which is a kind of movable and reliable static instrument. With its accuracy up to 0.8% and comparatively large dynamic ...


    By A.YITE Technology

  • Flow Tip Video: Learn Why Ease-of-Use is Critical for Flow Meter Selection

    Many times scientists and researchers spend more time setting up equipment and instrumentation for their experiments than conducting actual experiments to gather important data. This holds true for flow meters and controllers to measure and control gases to experiments. Some flow meters are very cumbersome with no display, can only measure one ...


    By Sierra Instruments, Inc.

  • DFM 5.0 doppler flow meter for frac sand slurry flow monitoring - Case Study

    CanFrac Sands Ltd. of Lloydmister Saskatchewan (Canada) needed a flowmeter that could accurately measure sand slurry flow without being damaged by this highly abrasive product. They selected the Greyline DFM 5.0 Doppler Flow Meter with a clamp-on ultrasonic sensor mounted on the outside of a pipe. CanFrac produce “fracturing sand” used by the oil and gas industry. This special type of ...


    By Greyline Instruments Inc.

  • [Minute Flow Tip Video] Mass Flow Versus Volumetric Flow Technology

    When engineers and systems integrators need to measure gas flow rate in an industrial process or scientific research, there are many types of technologies to choose from.  This makes selecting the right gas flow meter a challenge. In addition to technology, engineers must consider many other parameters: price for value, cost of ownership, size of footprint, ...


    By Sierra Instruments, Inc.

  • Minute Flow Tip Video - Mass Flow Versus Volumetric Flow Technology

    When engineers and systems integrators need to measure gas flow rate in an industrial process or scientific research, there are many types of technologies to choose from.  This makes selecting the right gas flow meter a challenge. In addition to technology, engineers must consider many other parameters: price for value, cost of ownership, size of footprint, ...


    By Sierra Instruments, Inc.

  • Accurate management of waste water flow case study

    SmartScan 50O provides an accurate ultrasonic solution for flow measurement of waste water in a nation-wide advanced treatment plant. This wastewater treatment plant is located just outside a pop. 1 Million City. The plant provides wastewater treatment services for the municipality since 1999. The plant utilizes the latest technology of wastewater treatment that enables purification of ...

  • Smart meters: Truly a cure for energy blindness?

    And now for a dose of reality.   No doubt smart meters are a good thing, but even their most ardent fans must admit that a degree of hoopla surrounds these little digital boxes. We hear that if consumers can just see how much power they use in real time, and what it costs, our energy woes will be no more.   Smart meters will even cure the blind. The energy blind that ...

  • How to Supercharge the SmartTrak Mass Flow Controller with Compod

    Streamline, simplify and save time and money by plugging the innovative Compod upgrade into the face of any SmartTrak 100 mass flow meter or controller. SmartTrak is not only a true multi-gas digital mass flow controller, it can control your process too. ...


    By Sierra Instruments, Inc.

  • Providing Precision Flow Control Solutions for Critical Biomolecular Research

    When scientists at the University of Nottingham’s Centre for Biomolecular Sciences (CBS) in the United Kingdom needed instrumentation to control the flow of gases in their research, they turned to Litre Meter, a UK distributor for Sierra Instruments, and the SmartTrak 100 series mass flow meters and ...


    By Sierra Instruments, Inc.

  • New Video: Master Your Mass Flow Control Challenges

    For over 40 years, Sierra has pioneered the development of precision gas mass flow controllers. Today, our high-performance SmartTrak lineup, with over 100,000 successful installations, proves we’ve never let up. For Lab Researchers and  ...


    By Sierra Instruments, Inc.

  • Casella intrinsically safe TUFF personal air sampling pump and dBadge sound level meter are a hit down under with Australian department of defence

    Following a competitive tender process, the Australian Department of Defence has taken delivery of 180 TUFF personal air sampling pumps and 180 CEL-350 dBadge personal noise dosimeters from Casella CEL (www.casellameasurement.com; 01234 844100), leading global specialist in industrial hygiene and occupational health monitoring equipment. Ronald Azar, ...


    By Casella

  • A Low-Cost Electrolytic Tiltmeter for Measuring Slope Deformation

    The tiltmeter described consists of an electrolytic sensor (a glass jar containing an electrolyte and six electrodes) and a portable AC digital conductivity meter, which reads conductivity changes resulting from tilting deflections. The tiltmeter has a sensitivity of 2 to 8 min of arc/cmu (conductivity meter unit), with a measurement range of more than 45°. This tiltmeter measured earth flow ...


    By ASTM International

  • Core technology part 2: transit-time ultrasonic

    Since the introduction of ultrasonic transit-time flow meters, manufacturers have continually improved their measurement and signal processing capabilities. Recent advances in digital correlation transit-time technology allow customers to use this convenient, non-intrusive installation to address some of the more challenging flow applications. Ultrasonic flow meters are divided into two ...


    By Sierra Instruments, Inc.

  • OTT ADC measurement - Germany

    Background As the open pit Cottbus Nord is making use of the water of the ponds in the protected landscape of Lakoma (a village 6 km from Cottbus) the Vattenfall Europe Mining AG (VEM) as owner of the pit was obligated to take compensation measurements. VEM entrusted the engineers of the gerstgraser Ingenieurbüro für Renaturierung (gIR) in Cottbus with the planning of the ...


    By The OTT Hydromet Group

  • DEFRA use rainwater recycling system

    DEFRA new stores building located in Weybridge, Surrey is a light commercial industrial unit. Aquaco were asked to provide a rainwater recycling (harvesting) system. Our response Aquaco proposed a system consisting of a 3,000 litre capacity rainwater recycling system complete with filtration, UV disinfection unit, pump sets, digital temperature and level sensors, header (break) ...

  • Sound recording to characterize outdoor tap water use events

    Obtaining disaggregated water use at the home typically involves expensive smart metering. In this study, water use events at the outdoor tap were captured using recorded sound. Outdoor taps at 10 homes were fitted with small-sized microphones and digital sound recorders. Sound files recorded over a 1-month period were used in the analysis. In the preliminary analysis, a human operator browsed ...


    By IWA Publishing

  • Understanding 4-20mA Communications

    Imagine this: You’ve got your meter with 4-20mA output setup. Confidently, you flip the switch, turning it on, and then it happens: the readings are off. You’re not getting the output you need. Frustrated, you tinker with it, and still nothing. Now, you’re out of your depth. You need to get this thing working so you can get your application up and running. What are you ...


    By Sierra Instruments, Inc.

  • Bench-scale study of ultrafiltration membranes for evaluating membrane performance in surface water treatment

    Currently, there is no standard bench-scale dead-end ultrafiltration (UF) testing system. The aim of the present study was to design and build a bench-scale hollow fiber UF system to assess the impact of operational parameters on membrane performance and fouling. A bench-scale hollow fiber UF system was built to operate at a constant flux (±2% of the set-point flux) and included automated ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you