dissolved oxygen measurement Articles

  • ppb Dissolved oxygen measurement

    Dissolved oxygen (D.O.) measurement is one indicator of water quality because oxygen is a common element contributing to corrosion reactions. This corrosion reaction provides the need for low level D.O. control since dissolved oxygen is responsible for costly replacement of piping and equipment by corrosive attack on metah. what is Dissolved Oxygen? Dissolved axygan (D.O.f is the ...


    By IC Controls Ltd.

  • ppm Dissolved oxygen measurement

    Dissolved oxygen (D.O.) levels are used as a general indicator of water quality. Oxygen is essential to life and vital for countless aquatic forms. D.O. level control is critical in numerous applications ranging from the monitoring of industrial waste water to environmental surveillance. What is Dissolved Oxygen? Dissolved oxygen (D.O.) is the amount of oxygen gas dissolved in a ...


    By IC Controls Ltd.

  • Effect of Dissolved Oxygen (and Bubbles) on the Measured Permittivity of Geotextiles

    Measurements are made of the permittivity in a heat set, nonwoven staple filament polypropylene as a function of the dissolved oxygen content (DOC) of the water. Vacuum deairing of the water to a DOC of 5 ppm or below insures that the measured permittivity will not be lowered by oxygen effects. Careful long-term measurements show that the measured permittivity is reduced very significantly if the ...


    By ASTM International

  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate ...


    By Partech (Electronics) Ltd.

  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate measurements of Dissolved Oxygen in activated sludge plants for the following reasons: To ...


    By Partech (Electronics) Ltd.

  • Dissolved Oxygen – the discussion moves on

    Do Dissolved Oxygen Sensors need Cleaning? The re-emergence of Optical Dissolved Oxygen Sensors around 6-7 years ago generated a lively and interesting discussion which revolved around the relative merits of Optical and Galvanic Dissolved Oxygen sensors. We understand that opinions will differ, so in order to accommodate our customers preferences we are pleased to offer our OxyTechw² ...


    By Partech (Electronics) Ltd.

  • Boiler Dissolved Oxygen Control

    DISSOLVED OXYGEN CHEMISTRY Dissolved Oxygen (DO) is a measure of the amount of oxygen, usually thought of as a gas, that is dissolved in a liquid such as water. Oxygen is essential to life and is also the most common element found taking part in corrosion reactions. DO can be thought of as the fuel needed for the corrosion process to proceed. It is the corrosion reactions that necessitate ...


    By IC Controls Ltd.

  • Dissolved oxygen’s effect on ecosystems

    Dissolved oxygen (DO) is a measure of the amount of oxygen dissolved in water. It can be caused by a process of aeration of water flowing through rapids or falls, a byproduct of photosynthesis and the atmosphere. Monitoring DO levels in water may be more important than you think. From dead fish washing up on the shores of Singapore, to historically low levels of brown shrimp, DO is having an ...


    By Aquaread Limited

  • In-Situ® Optical RDO® Methods for Dissolved Oxygen Measurements Outperform Traditional Methods

    ABSTRACT Three methods are generally used to measure dissolved oxygen (DO) in surface waters: Winkler titration, membrane-covered electrochemical sensors (polarographic or galvanic cell), and luminescent-based sensors. Optical (luminescent) technology for measuring DO levels in water has quickly become a well-accepted method due to many advantages over membrane-based sensors, and its close ...


    By In-Situ, Inc.

  • Retrofit decreases dissolved oxygen at low load

    Teresa Hansen, Section Editor Entergy’s Little Gypsy Unit 2 is a 450 MW gas-fired (with an oil alternative) thermal power plant originally designed for base load operation. Since changing over to peaking power operation, the plant has had problems with excessive dissolved oxygen (DO), especially during periods of low load. Entergy hired Intek Inc. to use a nontraditional ...


    By Intek, Inc.

  • Dissolved oxygen measurements in aquatic environments: The effects of changing temperature and pressure on three sensor technologies

    Dissolved oxygen (DO) is probably the most important parameter related to water quality and biological habitat in aquatic environments. In situ DO sensors are some of the most valuable tools used by scientists and engineers for the evaluation of water quality in aquatic ecosystems. Presently, we cannot accurately measure DO concentrations under variable temperature and pressure conditions. ...

  • In-Situ® Rugged Dissolved Oxygen (RDO®) Sensors Use the Latest Advancements in Optical Measurement Technology

    Dissolved oxygen (DO) is one of the most important parameters monitored when evaluating water quality, aquatic biology, and other environmental and industrial processes. The In-Situ Rugged Dissolved Oxygen (RDO) Sensor measures DO using the latest advancements in optical measurement technology. Water quality professionals will benefit from In-Situ Inc.'s investment in new product development. By ...


    By In-Situ, Inc.

  • Improved UV/O3 method for measuring the chemical oxygen demand

    We improved the ultraviolet (UV)/O3-based method for measuring chemical oxygen demand (COD) in water. An on-line COD monitoring device was developed and the UV/O3 method was used to oxidize sample solutions. A model was established by using support vector machines (SVM) algorithm to estimate dissolved oxygen and CO2 in solutions. Based on the measured data by each sensor ...


    By IWA Publishing

  • Product of the Month – Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger

    This month the focus is on the Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger. Over the summer months we have seen increased interest in the instrument. Warmer temperatures can affect the chemistry, biological processes and dissolved oxygen levels in water, making the Handy Polaris 2 a popular ...


    By Partech (Electronics) Ltd.

  • Prediction of dissolved oxygen in reservoirs using adaptive network-based fuzzy inference system

    Predicting water quality is the key factor in the water quality management of reservoirs. Since a large number of factors affect the water quality, traditional data processing methods are no longer good enough for solving the problem. The dissolved oxygen (DO) level is a measure of the health of the aquatic system and its prediction is very important. DO dynamics are highly nonlinear and ...


    By IWA Publishing

  • Comparing Performance of Dissolved Oxygen Probes and Examining Payback of the RDO PRO Probe Used to Monitor Aeration Basins

    Introduction Wastewater Treatment Plants (WWTPs) can use reliable dissolved oxygen (DO) data to improve operations, especially with continuous DO monitoring and realtime data acquisition. When DO probes and controllers are connected to blower controls through a SCADA system, the Publicly Owned Treatment Works (POTW) or WWTP will be able to: Optimize sewage treatment ...


    By In-Situ, Inc.

  • Measuring Short-Term BOD

    Measurement of oxygen uptake rates in activated sludge processes is essential to their satisfactory operation. Traditionally, oxygen uptake rates (OUR) have been determined by using a dissolved oxygen probe to measure the change in dissolved oxygen in a BOD bottle. While this method is rapid, it provides only a snapshot, at a single point in time, of the oxygen uptake rate reaction in a treatment ...


    By Challenge Technology

  • Water quality measurement extreme

    Background The characteristics of the Rio Tinto in the south-west of Spain, near Sevilla, are his ruby colour and the extremely sour pH-value between 0 and 2 pH-units. The river carries a mixture between poisonous heavy metals like copper, nickel, arsenic, iron and cadmium, dissolved in high-percent sulphuric acid. It’s not proved where these unusual conditions come from. As per current ...


    By OTT HydroMet

  • Oxygen Transfer in a Biological Aerated Filter

    The City of San Diego (City) operates the Point Loma Wastewater Treatment Plant (PLWTP) which can normally treat up to 240 million gallons per day (MGD) of chemically enhanced primary treated (CEPT) effluent for ocean disposal. The City wanted to understand the performance capabilities of Biological Aerated Filters (BAFs) in treating CEPT effluent to secondary standards. To this end, the City ...

  • What are the differences between Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD)?

    Ask the expert: What are the differences between Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD)? Answer: Both COD and BOD test methods aim to give an indication of the amount of pollution in a water sample. COD is the amount of oxygen required to chemically breakdown the pollutants whereas BOD is the amount of oxygen ...


    By Camlab Limited

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you