  • Boiler Dissolved Oxygen Control

    DISSOLVED OXYGEN CHEMISTRY Dissolved Oxygen (DO) is a measure of the amount of oxygen, usually thought of as a gas, that is dissolved in a liquid such as water. Oxygen is essential to life and is also the most common element found taking part in corrosion reactions. DO can be thought of as the fuel needed for the corrosion process to proceed. It is the corrosion reactions that necessitate ...


    By IC Controls Ltd.

  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate measurements of Dissolved Oxygen in activated sludge plants for the following reasons: To ...


    By Partech (Electronics) Ltd.

  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate ...


    By Partech (Electronics) Ltd.

  • Product of the Month – Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger

    This month the focus is on the Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger. Over the summer months we have seen increased interest in the instrument. Warmer temperatures can affect the chemistry, biological processes and dissolved oxygen levels in water, making the Handy Polaris 2 a popular ...


    By Partech (Electronics) Ltd.

  • On-Line Nitrate/Nitrite Probes for BNR Process Control

    ABSTRACTReal time nitrogen monitoring plays an increasingly important role for the successful biological nutrient removal at wastewater treatment plants. Though traditionally dissolved oxygen has been the main process control parameter a greater understanding of the biological mechanisms and process conditions like nitrite/nitrate concentrations to achieve lower effluent values becomes necessary, ...

  • Theory to Practice: Oxygen Transfer and the New ASCE Standard

    ABSTRACTOxygen transfer is an important part of wastewater treatment and accounts for as much as 60% of the energy consumption for the activated sludge process. Prior to 1984, no standard method for quantifying oxygen transfer existed, which created problems in the design and warranties for treatment plants. The ASCE Standard for the Measurement of Oxygen Transfer in Clean Water and the ASCE ...

  • Probing the debromination of the flame retardant decabromodiphenyl ether in sediments of a boreal lake

    After decades of using polybrominated diphenyl ethers (PBDEs) as flame retardants, a large reservoir of these toxins has accumulated in ecosystems worldwide. This study used an innovative approach to examine whether the fully brominated PBDE, decabromodiphenyl ether (decaBDE), degrades to more toxic congeners in aquatic environments. We incubated intact sediment microcosms with high‐purity ...


    By John Wiley & Sons, Ltd.

  • Can I use two probes of the same type with a Hach HQ40D meter?

    Yes – two probes of the same type can be used with the Hach HQ40D. The Hach HQ40D is a multi meter with ...


    By Camlab Limited

  • Measuring Short-Term BOD

    Measurement of oxygen uptake rates in activated sludge processes is essential to their satisfactory operation. Traditionally, oxygen uptake rates (OUR) have been determined by using a dissolved oxygen probe to measure the change in dissolved oxygen in a BOD bottle. While this method is rapid, it provides only a snapshot, at a single point in time, of the oxygen uptake rate reaction in a treatment ...


    By Challenge Technology

  • Water quality measurement extreme

    Background The characteristics of the Rio Tinto in the south-west of Spain, near Sevilla, are his ruby colour and the extremely sour pH-value between 0 and 2 pH-units. The river carries a mixture between poisonous heavy metals like copper, nickel, arsenic, iron and cadmium, dissolved in high-percent sulphuric acid. It’s not proved where these unusual conditions come from. As per current ...

  • Water quality in the Arosa Bay

    Background One of the great impediments to further development of shellfish aquaculture in the north-west region of Spain isa perception that industry expansion and tourism could have negative environmental effects on the coastal waters. Especially the bay around Villagarcia de Arosa is very famous because of its excellent areas for shellfish farming. The government of Spain is ...

  • In-situ quality monitoring station in Lower Saxony

    Background 'Duemmer' is a shallow lake in the south-west of Lower Saxony; through the lake flows the river 'Hunte'. The catchment area spans 426 km2. With a surface of 12.4 km2 and an average depth of 1.1 m there is a water volume of approx. 14 million m3. Large parts of the lakeside are a nature reserve and the lake is a popular local recreation area. The lake suffers from strong nutrient ...

  • Optical DO Sensors Opening Doors to Online Aeration Control

    BACKGROUNDThe benefits of using online, automated control of aeration systems using dissolved oxygen (DO) sensors are well known in the industry and have been widely documented (e.g. Olsson et al, 2005). In most wastewater treatment facilities using activated sludge, the electricity provided to the aeration system is one of the most significant operating costs and a good control system can help ...

  • Monitoring pH and ORP in a SHARON reactor

    This paper analyses the valuable information provided by the on-line measurements of pH and oxidation reduction potential (ORP) in a continuous single high ammonia removal over nitrite (SHARON) reactor. A laboratory-scale SHARON reactor equipped with pH, ORP, electric conductivity and dissolved oxygen (DO) probes has been operated for more than one year. Nitrogen removal over nitrite has been ...


    By IWA Publishing

  • Water quality monitoring with hydrolab MS5

    Background The Škocjan caves are a unique natural phenomenon located in south western Slovenia and are preserved as the Škocjan Caves Park under UNESCO protection. One of the most famous network of underground caves in the world, they were formed by the flow of the Reka River as it bored tunnels through the region’s limestone geology. The river first disappears underground just outside the ...

  • Waterquality in irrigation canals and boreholes - Greece

    Background Kavala is located in the North East of Greece, 680 km from the capital Athens. The population of the prefecture of Kavala is around 85,000 people. The River Nestos which flows through this prefecture is very important for the agriculture of the area. To allow for a fair distribution of the water for irrigation purposes, a number of Boreholes and canals have been established. The ...

  • Reliable silica monitoring supports power station efficiency

    West Burton B CCGT is a Combined Cycle Gas Turbine power station near Nottingham in the UK. It has three open-cycle gas turbines capable of generating enough electricity for approximately 1.5 million UK homes. In common with all combustion based power stations, the CCGT has a requirement to monitor silica levels in the Plant’s water and steam processes. Sean Todd, the Plant’s Control ...

  • Efficient Waste Water Treatment

    Clean drinking water is an essential need of mankind. Often surface water like rivers or lakes is used as drinking water source. To prevent these resources from pollution the effective treatment of waste water is a must. For example in China 75% of discharged waste water is coming from pulp and paper, textile and dyeing industries. To run a waste water treatment plant in the most efficient way ...


    By J.V. Niebergall CDH

  • Monitoring watershed health

    Background Municipal water quality managers recognize the need for data that can be used to monitor and assess the impact of urbanization on the condition of natural watersheds. Storm events, in conjunction with the alteration of native landscape, building of roads and overuse of fertilizer, can contribute to excess nutrients, sediment and other pollutants in environmentally significant ...

  • Dairy Crest – Dairy Effluent Treatment Case Study and Partech Water Instruments

    In order to comply with environmental regulations, the food and beverage industry relies heavily on constant monitoring and control of wastewater and effluent, before discharge from the plant. Additionally, if process plants fail to be vigilant when it comes to monitoring all areas of waste treatment, the results can be unsuccessful. Partech’s water instruments are ...


    By Partech (Electronics) Ltd.