drinking water disinfectant system Articles

  • Genotoxicity and effects of nanosilver contamination in drinking water disinfection

    This study was conducted to examine the genotoxicity and the influence of silver nanoparticles (AgNPs) contamination when drinking water is exposed to five different disinfection treatments: chlorine, chlorine dioxide, ozone, ozone/chlorine and ozone/chlorine dioxide. Experiments were conducted with water samples of different chemical composition, from three water supply systems in Croatia. ...


    By IWA Publishing

  • New DWI guidelines for UV drinking water disinfection

    atg UV, has seen increasing interest in the application of UV systems for the treatment of drinking water applications since the UK Drinking Water Inspectorate (DWI) released their ‘Guidance on the use of Ultraviolet (UV) Irradiation for the Disinfection of Public Water Supplies' February 2010. With systems treating in excess of 2000 m3/hr daily, Ultraviolet disinfection is no longer an ...


    By atg UV Technology

  • Effects of phosphorus on biofilm disinfections in model drinking water distribution systems

    Drinking water biofilm development is affected by the available nutrient levels and the presence of disinfectants. Phosphorus is recognized as another important limiting nutrient besides organic carbon. In this study, drinking water biofilms were developed in annular reactors to examine the effects of phosphorus on the biofilm disinfections with free chlorine and monochloramine. Phosphorus ...


    By IWA Publishing

  • Disinfection by-products in drinking water – a case study on Calgary, Alberta, Canada

    Disinfection by-products (DBPs) have been monitored in Calgary's drinking water for approximately 15 years. The variability of the DBPs has typically exhibited similar patterns over the period of monitoring. Due to the nature of the surface waters supplying the water treatment plants, the level of DBPs was largely influenced by surface runoff events where the level of natural organic matter (NOM) ...


    By IWA Publishing

  • Selling UV disinfection systems

    A potential customer has inquired about employing your services to install a UV disinfection system. You set up an appointment for an estimate and to determine what will be involved for the installation. As the customer looks on, you turn on the Real UVT meter and proceed to test a sample of their water. Within a couple of minutes your Real UVT meter has provided you with the UV percent ...


    By Real Tech Inc.

  • Development and evaluation of a small scale water disinfection system

    Provision of microbiologically safe drinking water for people living in the rural areas of developing countries remains a major challenge to date. A simple gravity-driven membrane point of use system was developed based on woven fabric microfiltration (WFMF) membranes. The WFMF is a loose type of membrane (0.45 μm). However, complete disinfection is not achieved with the WFMF, hence it was ...


    By IWA Publishing

  • Crossville, TN, municipal drinking water

    The Situation: The City of Crossville, Tennessee, needed to address increasingly strict regulations on the use of gas chlorine to disinfect their community’s water. The Solution: By switching from gas chlorine to MIOX mixed oxidants, the City has reduced operational costs, improved residual durability, reduced byproduct formation, produced longer filter ...


    By MIOX Corporation

  • Alternative Disinfectants and N-Nitrosamines in Drinking Water: are we really Managing Human Health Risks?

     ABSTRACT North American drinking water utilities are increasingly incorporating alternative disinfectants, such as chloramines, in order to comply with disinfection by-product (DBP) regulations. NNitrosodimethylamine (NDMA) is an unregulated, non-halogenated DBP associated with chloramination, having a drinking water carcinogenic unit risk two to four orders of magnitude greater than ...

  • Tracking disinfection by-products and arsenic removal during various drinking water treatment trains

    In the central Banat region (Northern Serbia), groundwater is used as a drinking water source. Raw water originates from a 40–80 m and 100–150 m deep layer. It contains a high amount of natural organic matter (DOC = 9.17±0.87 mg C/L) with a trihalomethanes formation potential of 448±88.2 μg/L and a haloacetic acid formation potential of 174±68.9 μg/L. A high amount of arsenic (86.0±3.4 μg/L) is ...


    By IWA Publishing

  • Effects of tap water processing on the concentration of disinfection by-products

    Aim: This study examined the effects on disinfection by-product (DBP) concentrations of common household methods for processing drinking water.Methods: We investigated the effects of refrigerator storage, jug filtering, boiling in an electric kettle, and supply from an instant boiling water unit, with or without filtering, on four species of trihalomethanes (THMs) and nine species of haloacetic ...


    By IWA Publishing

  • A pulsed light system for the disinfection of flow through water in the presence of inorganic contaminants

    The use of ultraviolet (UV) light for water disinfection has become increasingly popular due to on-going issues with drinking water and public health. Pulsed UV light has proved to be an effective form of inactivating a range of pathogens including parasite species. However, there are limited data available on the use of pulsed UV light for the disinfection of flowing water in the absence or ...


    By IWA Publishing

  • Supreme hotel relies on supreme water disinfection by Grundfos

    Kempinski Hotel Zografski is a 5-star hotel located in Lozenets, near downtown Sofia, Bulgaria. It is one of the most luxurious hotels in the capital of Bulgaria. It has 442 guest rooms, 10 conference rooms, 5 restaurants, 3 bars and the only Japanese garden in the Balkans. The hotel was built between 1974 and 1979 to the design of leading Japanese architect Kisho Kurokawa (1934 - 2007) in the ...


  • UV Systems for Reclaimed Water Disinfection – From Equipment Validation to Operation

    The Sanitation Districts of Los Angeles County (Districts) operate seven tertiary water reclamation plants (WRPs) with a combined treatment capacity over 200 million gallons per day (MGD). Although chloramination has provided reliable and effective disinfection, the Districts decided to change this disinfection practice at one of the WRPs to ultraviolet (UV) irradiation to minimize ...

  • Emerging Trends In UV Disinfection For Water Treatment

    Introduction The UV disinfection industry has experienced tremendous growth over the last 20 years.  The development of new UV technologies over this period has been a perfect example of an industry investing to meet market demand – in this case demand for an effective, low cost, and environmentally friendly disinfection technology.  The acceptance of UV disinfection at water plants ...

  • Survival of pathogens in drinking water plumbing systems: impact factors and sanitation options

    The objective was to determine impact factors that would allow Pseudomonas aeruginosa and Legionella pneumophila to survive sanitation measures of household drinking water systems. Therefore, different disinfectant concentrations were tested under different operating conditions in close-to-practice experiments. Particular attention was paid to the viable but non-culturable ...


    By IWA Publishing

  • Key Operating Strategies for Chlorine Disinfection Operating Systems

    ABSTRACTChlorine has been used as a standard for disinfecting wastewater for many years. While being the standard There are many levels of automation for control of disinfection. To select the best control approach for your facility both control strategies and chlorination chemistry must be understood. Permit conditions must also be fully identified; organism concentrations and operational data. ...

  • Strontium adsorption and desorption reactions in model drinking water distribution systems

    Divalent cationic strontium (Sr2+) adsorption to and desorption from iron corrosion products were examined in two model drinking water distribution systems (DWDS). One system was maintained with chlorine-disinfected drinking water and the other with the same water with secondary chloramine disinfection. Flow conditions simulated primary transmission lines (constant flow) and residential ...


    By IWA Publishing

  • On Line Control Strategies for Disinfection Systems: Success and Failure

    ABSTRACTThere are many levels of automation for control of chlorination systems. To select the best control approach for a facility, both control strategies and chlorination chemistry must be understood. Permit conditions including organism concentrations and operating data must also be fully identified. Many States require compliance with organism concentrations, as well as residual chlorine and ...

  • Closed vessel or open channel UV disinfection systems

    Ultra violet disinfection is now a standard feature in most waste water disinfection systems. UV has also been adopted by the drinking water community, as a barrier against the chlorine tolerant species such as Cryptosporidium and Giardia. The technology is widely favored due to its non- chemical nature, the fact that no subsequent de-chlorination process is required, and its ability to be ...


    By atg UV Technology

  • Evaluating a composite cartridge for small system drinking water treatment

    A pilot-scale evaluation was conducted at the U.S Environmental Protection Agency (EPA) Test & Evaluation (T&E) Facility in Cincinnati, Ohio, on a multi-layer, cartridge-based system that combines physical filtration with carbon adsorption and ultraviolet (UV) light disinfection to serve as a home-base water treatment security device against accidental or intentional contaminant events. The ...


    By IWA Publishing