drinking water pipeline Articles

  • Detection of Minor Leakage in a Drinking Water Power Plant Pipeline

    Project in the South Tyrolean community Mals in Italy The final pressure test of a 2014 newly installed pipeline m a drinking water power plant in the South Tyrolean community Mals (Italy) showed a pressure loss out of range, which prevented the plant's commissioning. Thus the company MTA Messtechnik GmbH has been tasked to identify the reasons for the losses as quickly as possible ...


    By MTA Messtechnik GmbH

  • Gasoline pipeline break - Sun Pipeline Company

    LOCATION: Southeastern, PennsylvaniaPROJECT DATE:  November, 1984 to October, 1991CLIENT:  Sun Pipe Line Company BACKGROUND: A pipeline break resulted in the spill of 100,000 gallons of gasoline to a highly fractured shale aquifer. A number of private drinking water wells were affected. In excess of 10 homeowners were forced to vacate due to gasoline vapors in their homes. Producing ...


    By Terra Systems, Inc. (TSI)

  • Decontamination of a drinking water pipeline system contaminated with adenovirus and Escherichia coli utilizing peracetic acid and chlorine

    A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on ...


    By IWA Publishing

  • Our drinking water systems are a disaster. What can we do?

    In the wake of the Flint, communities turn to innovative technology and financing to prevent the next crisis. People in developed countries turn on the tap and safe drinking water flows, a dramatic health benefit they tend to take for granted. That complacency was dramatically disrupted last year when children in Flint, Michigan, started testing positive for lead poisoning and the ...


    By Ensia

  • Evaluation of drinking water quality in a water supply distribution network based on Grey correlation analysis

    The lack of access to clean drinking water adversely affects public health and life expectancy in many developing countries. However, not all cities' drinking water can currently meet drinking water standards. Therefore, determining reasonable water quality changes and the influence of various factors on water quality is important for improving drinking water quality. The objective of this study ...


    By IWA Publishing

  • 1700 miles of the keystone Xl Pipeline: A state, federal and international regulatory concern

    Regulatory compliance at the state and federal level grows infinitely more complex when the laws and regulations of six U.S. states, U.S. federal regulations, and the Canadian regulatory regime are intertwined.  TransCanada’s proposed Keystone XL Pipeline, currently awaiting approval from the U.S.  Department of State, is gaining as much attention for its regulatory ...

  • GE Leakwise Application Notes: Monitoring and Leak Detection for a Hydrocarbon Pipeline

    Hydrocarbon Pipeline •          Pipeline Leak Detection •          Pumping Station Monitoring • ...


    By GE Analytical Instruments

  • Testing and developing energy harvester systems for operation of energy-self-sufficient measurement and control units in drinking water supply

    In recent years, wireless measurement and control units have become more popular for monitoring water distribution systems in the drinking water supply. Electric power supply for a higher number of devices through fixed connections to the public electrical grid is technically complex and requires large investments. Powering monitoring devices, which are installed in areas where electrical ...


    By IWA Publishing

  • Multivariate data mining for estimating the rate of discolouration material accumulation in drinking water distribution systems

    Particulate material accumulates over time as cohesive layers on internal pipeline surfaces in water distribution systems (WDS). When mobilised, this material can cause discolouration. This paper explores factors expected to be involved in this accumulation process. Two complementary machine learning methodologies are applied to significant amounts of real world field data from both a ...


    By IWA Publishing

  • Treatment plant protected by effluent monitor at major drinks factory

    The installation of a BioTector continuous TOC (Total Organic Carbon) monitor to police the front end of Cobevco’s wastewater treatment plant has enabled tight control of the treatment process. Delivering results 20 times faster than laboratory techniques, the monitor at the Elton facility in Cheshire provides advance notice of organic overload so that the plant is able to instantly divert ...


  • Understanding water fact sheet

    Nearly 326 million trillion gallons of water cover more than 70 percent of the Earth, making it the most common element on the planet. Water is the only resource found naturally as a solid, liquid and gas. The atmosphere carries 40 trillion gallons of water across the country and drops 40 percent of its moisture as precipitation every day. All of this water helps regulate the temperature and ...


    By Kinetico International

  • Water Reuse Terminology

    All water on Earth is used and reused, over and over, in an elegant water cycle. Water reuse occurs in various ways on a daily basis. It happens when a community’s treated wastewater is discharged into rivers or other water bodies. If you live in a community downstream of another, chances are you are reusing water from an upstream town. Scientifically proven advances in water technology ...


    By WateReuse

  • Water reuse and reclamation: a contribution to energy efficiency in the water cycle

    Water and energy are two of the most important resources of the 21st century. Water is required to supply energy and, at the same time, energy is required to supply water. In urban water management, the key factor is warm water heating. Depending on the quality of the raw water, the provision of drinking water requires the application of different process technologies; the more complex the ...


    By IWA Publishing

  • Unique technology for monitoring piped water

    INTELLITECT WATER has launched a unique, highly innovative drinking water monitoring technology that will revolutionise the delivery of drinking water. The new technology monitors the quality of water in pipeline distribution networks and for the first time provides reliable data to protect the integrity of the water quality, to enhance customer satisfaction and to improve operational efficiency. ...


    By Intellitect Water Ltd

  • Advanced Water Treatment Technologies May Bring Purified Water to San Diego

    'In four years, half of San Diego may be filling its glasses with tap water that once ran through its toilets,' reported the San Diego Union-Tribune recently. A plan to mix 'repurified water' with the City's raw drinking water reservoir could become a reality, thanks to the wonders of water treatment technology. Such a possibility elicits various reactions including disgust, marvel and fear. ...

  • Rethinking Big Water - Is It Time For A New Approach To Municipal Water Infrastructure?

    Las Vegas has long served as a stereotype of human excess: gambling, drinking, sex, all-you-can-eat buffets. But the latest chapter is playing out away from the Strip, in the part of the valley where two decades of booming development have swelled the population to 2 million residents who rely on a dwindling water supply. Ninety percent of the southwestern U.S. city’s drinking water comes ...


    By Ceres

  • Influence of porous media on intrusion rate into water distribution pipes

    Untreated water can intrude into water distribution systems through pipe leaks and cracks when negative pressure events occur inside drinking water pipelines. The orifice equation is typically used for calculation of intrusion flow rate, which ignores the impact of the soil surrounding the pipeline. This paper presents the results of an experimental study on the effect of porous ...


    By IWA Publishing

  • Case study - Metropolitan Water District of Southern California (MWD)

    Service: Electromagnetic Inspection Client: Metropolitan Water District of Southern California (MWD) Type of Pipeline: Transmission Mains Diameter: 42 to 201-inch Pipe Material: PCCP Length: 163 miles The Metropolitan Water District of Southern California (MWD) is a consortium of 26 cities and water districts that provide drinking water to nearly 17 million people in parts ...


    By Pure Technologies

  • Water Treatment Plant: Benefits of Underwater Cameras

    Before fresh water can be made safe for human consumption it must go through a treatment process eliminating bacteria and any other elements deemed unsafe to drink. How does such a process occur and why is it relevant to us? We’ve written about the use of Deep Trekker remotely operated vehicles and pipe crawler systems in storm water systems, sanitation pipes, and water storage basins. A ...


    By Deep Trekker Inc.

  • Supreme hotel relies on supreme water disinfection by Grundfos

    Kempinski Hotel Zografski is a 5-star hotel located in Lozenets, near downtown Sofia, Bulgaria. It is one of the most luxurious hotels in the capital of Bulgaria. It has 442 guest rooms, 10 conference rooms, 5 restaurants, 3 bars and the only Japanese garden in the Balkans. The hotel was built between 1974 and 1979 to the design of leading Japanese architect Kisho Kurokawa (1934 - 2007) in the ...


Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you