dust emissions monitor Articles

  • Dust monitoring

    Generally, two different approaches are used to measure the amount of dust deposited on a surface; Determination of the soiling of a surface, by a change in its properties; Determination of the quantity of dust deposited, by weight. WHAT IS DUST? Dust is a generic term used to describe fine particles that are suspended in the atmosphere. Dust comes from a wide variety of sources, including soil, ...


    By Queensland Laboratory

  • New laser-based dust emission monitoring system

    Abstract A new generation of continuous particulate matter concentration monitoring instruments is presented, covering a measuring range of 0 to 1000 mg/m3. The laser-based scattered light instrument gives an improved stability as well as excellent resolution in the low range. This enables high concentration measurement as well as especially low emission monitoring down to 0.01 mg/m3 with a ...


    By Sigrist-Photometer AG

  • A Critical Evaluation of the South African Air Quality Offsets Guideline

    There is wide recognition in South Africa to the link between the quality of life and quality of the air we breathe. The Department of Environmental Affairs (DEA) attempts to improve air quality through two key regulatory tools; emission limits, which regulate the maximum concentration of certain pollutants permissible within certain, ‘listed’ industrial stacks or vents, and ambient ...


    By WKC Group

  • The invisible fine dust

    Air is lifeblood. Daily we inhale approximately 15.000 liter. Still, the air contains invisible pollutants, which vary in its composition and concentration depending on the location. Especially the respirable particles with a diameter of less than 2.5 µm (PM 2.5) were considered to be particularly dangerous. According to a current study conducted by the Max Planck Society, ...

  • Compliance to standards in continuous emissions monitoring case study

    Customer: Glass Manufacturer Application: Continuous Emissions Monitoring Service (CEMS) for Glass Manufacturing Background: A glass factory is required to ...


    By Ecotech Pty Ltd

  • The Use of Particulate Emission Monitors to Support Arrestment Plant Operation and Upkeep

    The operation of filtration type arrestment plant can be optimised by the effective use of Particulate Emission Monitors (eg Filter Leak Monitors and Filter Performance Monitors). Particulate Emission Monitors are installed throughout the broad spectrum of industrial processes to satisfy regulations (IPPC, Part B Guidance Notes, WID and LCPD) for emission limit enforcement. In addition, where ...


    By PCME Ltd

  • Controlling Dust and Bioaerosols at a Biosolids Composting Faclity

    Studies at enclosed Longmont, Colorado project evaluate exposure level of employees. Operational changes reduce dust, endotoxin and A. Fumigatus by 90 percent. WHEN dealing with public health issues and composting, attention has been predominantly focused on potential exposure from the release of Aspergillus fumigatus (A. fumigatus) from composting facilities. Numerous studies were conducted to ...


  • Exposure to dust, endotoxin and airborne microorganisms in wastewater sludge thermal drying units

    The objective of this study was to assess workers' exposure to bioaerosols in sludge drying units. Simultaneous collection of inhalable dust and airborne biological agents was carried out using rotating cup samplers (CIP 10, Arelco). Sixteen stationary and 30 personal measurements were performed in three drying plants, during summer and winter. Microbial content of air was characterized by high ...


    By IWA Publishing

  • Emissions analyser helps manage power station

    A multiparameter emissions monitor at Thetford power station is being used to demonstrate to the Environment Agency that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Milton Keynes based Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are ...


    By Quantitech Ltd

  • Monitoring Environmental Quality

    ' In order to determine the effectiveness of actions to improve environmental quality it is necessary to be able to measure relevant environmental parameters at a level of detail which is accurate enough to distinguish the anticipated changes. However, the establishment and maintenance of monitoring systems is time-consuming and expensive and therefore the scale of such systems needs to be kept ...


    By The World Bank

  • Controlling Stack Emissions in the Wood Products Industry

    Electrostatic precipitation has been a reliable technology since the early 1900's. Originally developed to abate serious smoke nuisances, the manufacturers of zinc, copper, and lead quickly found electric gas cleaning a cost efficient way to recover valuable product carried out of the stacks from furnace operations. Today electrostatic precipitators are found mainly on large power plants, cement ...


  • Casella BOUNDARY Guardian helps to control noise and dust on major London construction project

    Casella‘s BOUNDARY Guardian is helping to ensure noise compliance and control of air quality at BSkyB’s campus redevelopment site, bringing peace of mind to site operators, the client and the local community. The BOUNDARY Guardian is a system for web-based remote monitoring of noise and/or dust emissions that ensures compliance ...


    By Casella

  • FTIR Emissions Analyser helps manage UK Power Station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Gasmet Technologies Oy

  • FTIR emissions analyser helps manage UK power station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Quantitech Ltd

  • Continuous Mercury Monitoring Benefits Cement Plants

    Antti Heikkilä from Gasmet Technologies highlights the challenges faced by mercury monitoring in cement kilns, and explains how a new continuous mercury monitoring system addresses these issues and provides process operators with an opportunity to improve environmental performance and demonstrate compliance with forthcoming legislation. Background The production of cement ...


    By Gasmet Technologies Oy

  • Designing and Implementing Perimeter Air Monitoring Programs

    Perimeter or fenceline ambient air quality and meteorological monitoring programs have become increasingly valuable at hazardous waste, landfill, dredging, ports, and MGP remediation sites. Air quality monitoring programs protect public health and reduce owner liability ...


    By AECOM

  • Analysis of PCBs in emission samples: non ortho, mono-ortho and homolog totals by level of chlorination

    IntroductionPolychlorinated biphenyls (PCBs) are one of the most widespread persistent organic pollutants, identified in every component of the global ecosystem. A production of approximately 2 * 10 9 Kg technical PCB occurred form 1930 to the late 1970 1 and the total amount released into the environment is estimated in 370. 000 2 tonnes. Twelve of the possible 209 PCBs are non- and mono-ortho ...


    By Monitoring Systems GmbH

  • So Your Greenhouse Gas (GHG) Monitoring Plan is Complete... Now What?!?

    U.S. EPA's Greenhouse Gas Mandatory Reporting Rule (GHG MRR) codified at 40 CFR Part 98 required that facilities subject to the rule have a complete written GHG Monitoring Plan by April 1, 2010. At a minimum, the GHG Monitoring Plan must identify (1) methods used to collect GHG emissions information and supporting data, (2) personnel responsible for collecting the data, and (3) quality assurance, ...


    By All4 Inc.

  • NOx in Non-Utility Industries - Part II - Control options and monitoring methodology

     This the second in a two-part series. Part I, which appeared in our June 2001 issue focuses on air emission origins of nitrogen oxides (NOx) in non-utility industries. Choice of the NOx control technology is dependent on many factors, including regulatory requirements, technical feasibility, cost and public perception. Figure 1, compiled based on publications [1-5], presents a summary of ...


  • WHO report on diesel fumes puts sharp focus on need for effective monitoring

    The World Health Organisation this month reclassified the dangers of diesel exhaust fumes, upgrading the risk from probably carcinogenic to a definite cause of cancer. The WHO report is based on the findings of research on workers in high risk areas, and puts a sharp focus on the need for effective monitoring in industries such as mining, rail, transportation, construction, power generation and ...


    By Shawcity Limited

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you