dust filter performance monitor Articles

  • New laser-based dust emission monitoring system

    Abstract A new generation of continuous particulate matter concentration monitoring instruments is presented, covering a measuring range of 0 to 1000 mg/m3. The laser-based scattered light instrument gives an improved stability as well as excellent resolution in the low range. This enables high concentration measurement as well as especially low emission monitoring down to 0.01 mg/m3 with a ...


    By Sigrist-Photometer AG

  • The invisible fine dust

    Air is lifeblood. Daily we inhale approximately 15.000 liter. Still, the air contains invisible pollutants, which vary in its composition and concentration depending on the location. Especially the respirable particles with a diameter of less than 2.5 µm (PM 2.5) were considered to be particularly dangerous. According to a current study conducted by the Max Planck Society, ...

  • Controlling Dust and Bioaerosols at a Biosolids Composting Faclity

    Studies at enclosed Longmont, Colorado project evaluate exposure level of employees. Operational changes reduce dust, endotoxin and A. Fumigatus by 90 percent. WHEN dealing with public health issues and composting, attention has been predominantly focused on potential exposure from the release of Aspergillus fumigatus (A. fumigatus) from composting facilities. Numerous studies were conducted to ...


  • ‘New for old’ dust analyser deal brings 96.66% data capture rates to NE Lincs

    With the UK’s largest port and the industrial town of Grimsby in its jurisdiction, air quality monitoring is a primary concern for North East Lincolnshire Borough Council. When DEFRA reported that the TEOM dust analysers the council relied on weren’t up to standard, rapid action was required and Enviro Technology (ET) stepped in with its BAM 1020s. North East Lincolnshire is the ...

  • How well does my filter work?

    Contamination control is the key to a cost-effective maintenance operation for hydraulic or engine systems. You depend on your filters, whether hydraulic, lube or fuel, to keep your fluids clean, to keep maintenance costs down, and to ensure reliable operation. At some point, you probably will ask yourself whether or not your filters are really working and doing what they were designed to do. ...

  • American Upstart Filter Brand Competing with the Majors

    Flexotherm® has expanded its product line in the highly competitive filtration market.  The company now offers 2,900 different filter elements including coalescers, particulate, adsorbers, general purpose and high temperature filters. ...


    By Neptech Inc.

  • The Use of Particulate Emission Monitors to Support Arrestment Plant Operation and Upkeep

    The operation of filtration type arrestment plant can be optimised by the effective use of Particulate Emission Monitors (eg Filter Leak Monitors and Filter Performance Monitors). Particulate Emission Monitors are installed throughout the broad spectrum of industrial processes to satisfy regulations (IPPC, Part B Guidance Notes, WID and LCPD) for emission limit enforcement. In addition, where ...


    By PCME Ltd

  • Air Separation Plants and the Use of Oxygen Monitors

    Air separation plants are critical for many different industries, from clean energy to manufacturing. Nowadays, cryogenic is the most common type of distillation used to separate air into its component gases - nitrogen, oxygen, and inert gases including helium and argon. If your industry relies on air separation for product development or manufacturing, then knowing how the process works is ...

  • Minimising Risks to Air Quality and Regulatory Compliance With Total Filter Management

    It has been shown in recent studies that as much as 25% of the total site operating budget (excluding raw material costs) for a typical medium-large dosage-form manufacturing facility will be spent on compliance measures for internal quality systems and external regulatory activities. (1) Market realities indicate that the pharmaceutical companies will need to address the overall cost of ...


    By GVS Filter Technology

  • A 25-year long monitoring of lead content in the blood of cows from a stationary polluted area

    The monitoring has been performed on lead content in the blood of cows (n = 1,279) from farms (n = 1?14) near a former lead mine and current smelting plant from 1975 to 2003. Early measurements showed that average lead concentration in the blood of cows was 1.25 ? 0.58 mg/kg while in 2002 it was about 10-times to 20-times lower (0.069 ? 0.005 mg/kg). Significant decrease in blood lead ...


    By Inderscience Publishers

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Biomass fired thermal oil heater case study

    This 12 MWth output Biomass Power Plant is one of the turnkey products of Biomass Power. The plant was fully commissioned in December 2006. The system has a capacity of 12 MW thermal output producing up to 10MWth of 300°C 10 Barg pressure hot oil, up to 10 tonnes per hour of steam and 2 MWth of 200°C hot air. This is all achieved from one grate heating three separate heat exchanges. The ...


    By Biomass Power Limited (BPL)

  • 4.5 MWe Refuse Derived Fuel to Energy Plant Case Study

    This 4.5 MWe Biomass Power Plant is one of the turnkey products of Biomass Power. The plant has a capacity of 24 MW thermal and rated at 4.5 MWe producing 35,476MWh of green electricity per year, 100% of which is exported to the grid. The fuel used is segregated biomass from a commercial and industrial waste collection business. The fuel is produced by removing some of the recyclable material ...


    By Biomass Power Limited (BPL)

  • 2 MWe Biomass Power Plant Case Study

    This 2 MWe Biomass Power Plant is one of the turnkey products of Biomass Power. The plant was fully commissioned in September 2007. The plant has a capacity of 11 MW thermal and rated at 2MWe producing 15,700 MWh of green electricity per year, 100% of which is exported to the grid. The fuels used are from forestry and agricultural residues, wet woodchips, compost oversize, straw and miscanthus, ...


    By Biomass Power Limited (BPL)

  • Analysis of PCBs in emission samples: non ortho, mono-ortho and homolog totals by level of chlorination

    IntroductionPolychlorinated biphenyls (PCBs) are one of the most widespread persistent organic pollutants, identified in every component of the global ecosystem. A production of approximately 2 * 10 9 Kg technical PCB occurred form 1930 to the late 1970 1 and the total amount released into the environment is estimated in 370. 000 2 tonnes. Twelve of the possible 209 PCBs are non- and mono-ortho ...


    By Monitoring Systems GmbH

  • FTIR Emissions Analyser helps manage UK Power Station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Gasmet Technologies Oy

  • Emissions analyser helps manage power station

    A multiparameter emissions monitor at Thetford power station is being used to demonstrate to the Environment Agency that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Milton Keynes based Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are ...


    By Quantitech Ltd

  • FTIR emissions analyser helps manage UK power station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Quantitech Ltd

  • Thermal Power - Rehabilitation of Existing Plants Industry - Pollution Prevention Guidelines

    Introduction Pollution Prevention Guidelines to provide technical advice and guidance to staff and consultants involved in pollution-related projects. The guidelines represent state-of-the-art thinking on how to reduce pollution emissions from the production process. In many cases, the guidelines provide numerical targets for reducing pollution, as well as maximum ...


    By The World Bank