dust sampler Articles

  • Dust monitoring

    Generally, two different approaches are used to measure the amount of dust deposited on a surface; Determination of the soiling of a surface, by a change in its properties; Determination of the quantity of dust deposited, by weight. WHAT IS DUST? Dust is a generic term used to describe fine particles that are suspended in the atmosphere. Dust comes from a wide variety of sources, including soil, ...


    By Queensland Laboratory

  • The Fundamentals of the Air Sampler Calibration-Verification Process

    INTRODUCTION The calibration of an air sampling instrument using a reference air flow calibrator requires attention to scientific detail in order to establish that the instrument’s reported values are correctly stated and valid under the actual operating conditions of the air sampling instrument. DEFINITIONS For the purposes of this ...

  • Controlling Dust and Bioaerosols at a Biosolids Composting Faclity

    Studies at enclosed Longmont, Colorado project evaluate exposure level of employees. Operational changes reduce dust, endotoxin and A. Fumigatus by 90 percent. WHEN dealing with public health issues and composting, attention has been predominantly focused on potential exposure from the release of Aspergillus fumigatus (A. fumigatus) from composting facilities. Numerous studies were conducted to ...


  • Exposure to dust, endotoxin and airborne microorganisms in wastewater sludge thermal drying units

    The objective of this study was to assess workers' exposure to bioaerosols in sludge drying units. Simultaneous collection of inhalable dust and airborne biological agents was carried out using rotating cup samplers (CIP 10, Arelco). Sixteen stationary and 30 personal measurements were performed in three drying plants, during summer and winter. Microbial content of air was characterized by high ...


    By IWA Publishing

  • Leaves of Lolium multiflorum as indicators of airborne trace element distribution in Central Italy

    Ambient air contains particles, ranging from sub-micrometric aerosols to clearly visible dust and sand grains. Plants during evolution developed the ability to maximise light interception and CO2 assimilation and also the efficiency to collect the airborne pollutants. Therefore, plant tissues have been used as indicators of trace elements air pollution. Lolium multiflorum leaves were used as a ...


    By Inderscience Publishers

  • Asarco Plant site remediation case study

    Asarco, Inc. Omaha, Nebraska, USA For more than a century, the former American Smelting and Refining Company (Asarco) operated a lead refinery on the banks of the Missouri River in Omaha, Nebraska. Plant closure in 1997 presented an opportunity to reclaim the riverfront as public space. Led by HDR, this successful transformation became the largest voluntary clean up ...


  • Short-term variations in ambient particulates and their sources in Taichung, Taiwan

    Ambient particulate measurements were carried out using TE-PUF sampling and a Universal Air Sampler between 8 March and 25 April 2001 at Taichung. Samples were collected every 6 hours beginning at 0100 LST (Local Standard Time) each day at two sites, one at a university campus and the other at a roadside. Chemical species (Cl-, NO3-, ...


    By Inderscience Publishers

  • Ambient Air Sampling Methods

    Pollutants are nothing but any substance that may present in an atmosphere in such a concentration that it may harmful to surrounding, living organism or human being. Sampling and analysis of air pollutants is known as Air quality monitoring and it is major part of environmental monitoring. There are many advanced types of ambient air Sampling methods. we will learn here only which are most ...


    By Perfect Pollucon Services

  • Source contribution of atmospheric aerosols in Bangkok metropolitan area by CMB8 receptor model

    The CMB8 model was applied for source apportionment of particulate matter in Bangkok area. The 24 h of ambient data were collected and analysed for elemental composition during December 1996 to January 1997 by high volume air samplers at a station in Bangkok, Thailand. Seven source profiles and the average mass concentrations of 42 ambient data were used to run the chemical mass balance ...


    By Inderscience Publishers

  • Ambient Air Fence Line Application case study

    Customer: Confidential Application: Ambient air Fenceline application Background: The Victoria Environmental Protection Agency installed an Opsis DOAS open path system to measure Benzene & ...


    By Ecotech Pty Ltd

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Designing and Implementing Perimeter Air Monitoring Programs

    Perimeter or fenceline ambient air quality and meteorological monitoring programs have become increasingly valuable at hazardous waste, landfill, dredging, ports, and MGP remediation sites. Air quality monitoring programs protect public health and reduce owner liability ...


    By AECOM

  • Sick-building syndrome and building-related illness

    Significant health problems linked to very poor indoor air qualityIndoor Air Quality (IAQ) deals with the content of interior air that could affect health and comfort of building occupants. The IAQ may be compromised by microbial contaminants (mold, bacteria), chemicals (such as carbon monoxide, radon), allergens, or any mass or energy stressor are more prevalent than anyone could have predicted. ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you