Quantitative analysis of iron in flour
Abstract A quantitative analysis of Iron in flour via Xenemetrix EDXRF Laboratory Spectrometer System was performed by model EX-3600M. The minimum detection limit for Fe in flour matrix was determined to 0.8 ppm at 3 sigma. Objective To design an easy method by using EDXRF technique for quick and convenient measurements of Fe in flour at the level of tens of ppm. Background EDXRF is a ...
-
Xenemetrix EX-3600M (EDXRF) spectrometer analysis of the major elements in cement and compliance with ASTM Method C-114
Energy Dispersive X-ray Fluorescence (EDXRF) can play a vital role in this industry by giving accurate analytical results in a short time. ASTM C-114 is the test method used for the analysis of hydraulic cements. . The overview of Xenemetrix EX-3600M (EDXRF) spectrometer analysis of the major elements in cement and compliance with ASTM Method C-114 will be described in this article. Cement ...
-
Quantitative Analysis of Geological Samples- X-Calibur
Abstract Quantitative and qualitative analysis of geological samples (rocks and river sediments) was performed on Xenemetrix EDXRF Benchtop Spectrometer System, model X-Calibur Objective: Perform XRF measurements on certified geological reference materials to build calibration curves for the major oxides (Na2O, MgO, SiO2, Al2O3, SiO2, P2O5, SO3, K2O, CaO, TiO2, MnO and Fe2O3) and for trace ...
-
Case study for cement field
Energy Dispersive X-ray Fluorescence (EDXRF) can play a vital role in this industry by giving accurate analytical results in a short time. ASTM C-114 is the test method used for the analysis of hydraulic cements. . The overview of Jordan Valley’s EX-3600M (EDXRF) spectrometer analysis of the major elements in cement and compliance with ASTM Method C-114 will be described in this article. ...
-
Application Note - Comparison of minimum detection limits on X-Calibur with SDD detyector or Si-PIN diode detector
ABSTRACT - The minimum detection limits of several different elements in water and in oil solutions were determined on X-Calibur with a SDD detector installed or a Si-PIN diode detector installed. The MDL was determined at 3 sigma and 300 seconds acquisition times. The result is reported here. OBJECTIVE - To perform a quantitative comparison between the performance of X-Calibur with a SDD ...
-
Minimum detection limits of several different elements in water and in oil
Abstract The minimum detection limits of several different elements in water and in oil solutions were determined on X-Calibur with a SDD detector installed or a Si-PIN diode detector installed. The MDL was determined at 3 sigma and 300 seconds acquisition times. The result is reported here. Objective To perform a quantitative comparison between the performance of X-Calibur with a SDD ...