electrical leak detection survey Articles
-
Performance-Based Specification Of Electrical Leak Location Surveys For Geomembrane Liners
ABSTRACT Electrical leak location surveys can be a crucial part of the final quality control of geomembrane liner installations. The method has been offered as a commercial service since 1985 and is the only practical test method that can find holes in the liner after protective soil cover is put on the liner. During the past fourteen years the test method has been used on a wide variety of ...
-
Costs and Benefits of Geomembrane Liner Installation CQA
ABSTRACT Because the cost of third-party construction quality assurance (CQA) of geomembrane liner installations is typically comparable to the cost of the geomembrane liner, CQA must be optimized to obtain the most benefit for the owner, rate payers, and environment. A regulation-based CQA protocol usually includes testing the material, observing the quality control (QC) program of the liner ...
-
Locating Leaks in Geomembrane Liners of Landfills Covered With a Protective Soil
ABSTRACT The electrical leak location method was used to locate leaks in the geomembrane liners of single-lined and double-lined landfills covered with a protective soil cover. The landfills ranged in size from 0.40 hectare (one-acre) to 3.2 hectares (eight-acre). Water in the leak detection system under the primary liner indicated the primary liners were leaking. The principal of the electrical ...
-
Enhanced Geomembrane CQA through proper application of geomembrane leak location surveys
Abstract Historically, geomembrane construction quality assurance (CQA) has focused on destructive testing of welded seams to verify seam strength and integrity. Paradoxically, seams are not subject to significant stress and practically never fail in service, while holes and construction damage in the geomembrane are a much more widespread problem. The historical approach fails to evaluate how ...
-
Locating Geomembrane Liner Leaks under Waste in a Landfill
Abstract An Electrical Leak Imaging and Monitoring (ELIM SM) survey was used to locate leaks under 2.5 meters of stabilized waste in an active geomembrane-Iined landfill. The landfill is lined with two 2-mm thick HDPE geomembranes that are separated by a geonet drainage layer. The primary liner is covered with 600 mm of drainage sand and 2.5 meters of stabilized waste for a total cover thickness ...