electronic water conditioning Articles

  • The mystery of electronic water treatment unveiled

    The problems of scale are well known to those living and working in "hard" water areas. Scale is the undesirable consequence of water supplies becoming super-saturated with dissolved minerals.  These problems are of greater significance if found in industrial water systems and commercial buildings. Scaling problems commonly occur, even in "soft" water areas, when a fluid stream is ...

  • Preventing Rust Formation with Electronic Water Treatment

    The growing demand for water for industrial applications, power production and water supply has resulted in an increasing need for water treatment. The water used in industry comes from a range of sources such as rivers, lakes, wells and oceans and contains dissolved and suspended solids.  In addition the industrial world has to reuse water which in turn causes it to be highly concentrated ...

  • ELECTRONIC WATER TREATMENT REDUCES FOULING AND CORROSION IN PIPELINES

    Increasing pressure loss in the pipeline is often caused by scale corrosion or product fouling of the internal surfaces. This condition slows transmission and distribution capacity, and can require more than just routine maintenance if it remains unaddressed. Interior corrosion, fouling and leakage in pipeline systems will adversely impact bottom-line operations. ...

  • Electronic water treatment reduces fouling in heat exchangers

    The deposition of material on heat transfer surfaces is called fouling which significantly impacts on the thermal and mechanical performance of heat exchangers. Fouling increases the overall thermal resistance and lowers the overall heat transfer coefficient of heat exchangers as well as impeding fluid flow, accelerating corrosion and increasing pressure drop across the heat ...

  • Electronic Water Treatment Reduces Fouling In Reverse Osmosis

    Reverse Osmosis (RO) is used in processes requiring high-quality, purified water, such in semi-conductor processing or biochemical applications and can be used to treat boiler feed water, industrial wastewater or process water. A water purification technique, it reduces the quantity of dissolved solids in solution. RO uses waterline pressure together with energy consuming pressurizing pumps that ...

  • "Non-Chemical Water Conditioning at Schick: A Pollution Prevention Case Study"

    Untitled Document Overview Since 1994, the Schick company of Milford has ...


    By Dolphin WaterCare

  • A new vision on the condition of city of Toronto’s sewer networks

    Situation And Objectives After the amalgamation of Toronto in 1998, Toronto Water – the department in charge of managing the combined infrastructure systems – was mandated to consolidate all underground facilities data and centralize sewer inspection processes on behalf of the newly merged city. Ten years later, a great deal of work in this regard remained undone. It was a ...


    By CTSpec Inc

  • Electronic Water Treatment - An alternative solution to removing beerstone and limescale

    Beer contains 90% water and is the most important ingredient in determining its flavor.  Water contains calcium and is the most important mineral to the brewing process.  The levels of calcium in local water have determined the type of beer produced.  The different types of beer whether a light lager or a porter are for the most part due to the water profiles of the areas that made ...

  • Electronic Water Treatment Provides a Clean Line for Food and Drink Production

    The USA’s food and drink producers spend billions of dollar’s each year in downtime, increased energy bills and the early renewal of capital equipment caused by hard water limescale blocking lines and leaving calcium carbonate deposits on water fed equipment.  Scale and sludge formation are the result of the precipitation of compounds that are ...

  • From air conditioning to urban planning, defaults and standards create dysfunction by design

    How can we stop outdated assumptions from forcing us to waste? Personal heaters are a summer survival tool for many office workers chilled to the bone by hyperactive ventilation systems — an act of self-defense against an epidemic of overcooling that is wasting energy and confounding comfort in not only offices but also large shops, schools and other buildings. An audit ...


    By Ensia

  • In situ remediation of BTEX, MTBE and TPH using EAS as a terminal electron acceptor

    EAS, A Paradigm Shift in the Remediation of Petroleum Hydrocarbons The conventional wisdom for remediation of aquifers contaminated with petroleum hydrocarbons (PHCs) is to add oxygen. A recent EPA / British Petroleum study, however, concluded that most hydrocarbon plumes are anaerobic and depleted of sulfate and, therefore, adding oxygen is disadvantageous. Other studies have drawn ...


    By True Blue Technologies, Inc.

  • South Australia’s $403 million NSISP Uses a “Super” Valve to Perform in a Variety of Extreme Conditions

    NSISP is one of South Australian Water Corporation’s (SA Water) biggest infrastructure projects undertaken in Adelaide metropolitan to connect the north and south drinking water distribution systems and to increase access to their desalination plant. The project included the construction of 32 km of pipeline through metropolitan main roads and suburban inner streets. This is no small feat ...


    By Singer Valve Inc.

  • Field application of ChitoRem chitin complex as a slow release electron donor for dechlorination: Distler Brickyard Site, West Point, KY

    Background Chloroethene source area (mainly TCE) is present in low permeability sediments. The objective is to clean up the source and prevent migration of contamination to underlying aquifer, which is a local drinking water source. The selected approach enhances the formation permeability while simultaneously providing an electron donor, chitin, for anaerobic ...


    By JRW Bioremediation, LLC

  • Uncoupling CR(VI) Reduction in Mixed-Culture Biofilm Systems: Electron-Flow Pathway Analysis

    ABSTRACTThe electron transport pathway for microbial Cr(VI) reduction was investigated using specific inhibitors of the trans-membrane enzymes in a culture of Escherichia coli ATCC 33456 grown in a coculture with the phenol degrader, Pseudomonas putida DMP-1. The analysis involved blocking the electron flow pathway through the inner cell membrane at specific enzyme locations using known metabolic ...

  • Oil on Water Monitoring

    Northern Ireland Water operate a number of potable water plants around Lough Erne and the River Derg, these waterways are extremely popular with tourists and are used for pleasure crafts of various sizes, from jetskis to fully fitted 6 berth cruisers. These watercraft create an ongoing risk of floating oil from poorly maintained engines, as the watercraft have access to within 10 metres of the ...


    By Partech (Electronics) Ltd.

  • Model success for Melbourne Water

    Untitled Document Melbourne Water ...


    By Innovyze

  • The Cryptosporidium Water Crisis

    One major event to strike the water industry recently, was the Lancashire Cryptosporidium water crisis. Cryptosporidium is a parasite found in livestock, which can have some severe consequences on the gastrointestinal system when ingested. Lancashire has seen 300,000 households suffer from a water contamination incident that’s forced residents to buy bottled water for ...


    By Partech (Electronics) Ltd.

  • Ozone Brings Better Bottled Water

    The proliferation of bottled beverages worldwide and an increased awareness of consumer health issues have beverage bottlers rethinking how to keep their liquids safe for consumption. One problem they face is the need to deliver a product that is free of bacteria, to provide extended shelf life and product quality. Ozone has quickly become the disinfectant of choice among water bottlers ...

  • Southern water MLSS case study

    Southern Water has recently installed eight new Partech Turbi-Tech 2000LA systems at its East Worthing water treatment works for measuring Mixed Liquor Suspended Solids (MLSS) in the aeration tanks. This new installation takes Partech’s Turbi-Tech 2000LA and 7200 Series Monitor a step further in becoming the standard instrument for measuring mixed liquor throughout the whole of Southern ...


    By Partech (Electronics) Ltd.

  • Advanced Water Quality Techniques Course

    Abstract:The development of a strategic water quality monitoring program is based on prioritizing risks to public safety and economic reality. The development of global standardized methods and protocols for automated water quality monitoring would facilitate international communication of water quality information and comparison of standardized methods and protocols. The three primary methods ...


Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you