exhaust analyzer Articles

  • Case study - Engine cell exhaust: Catalytic oxidizer

    Overview Endurance testing of outboard motors for boats has typically been done in lakes and sometimes on barges. This testing was time consuming, presented logistic problems and removed the testing from the R & D department and the factory. When a company in Oklahoma decided to build their own endurance test cell area, the Environmental Protection Agency required them to control the ...

  • Vapor intrusion mitigated through solar-powered exhaust systems

    EPA Region 6 undertook a Superfund removal action earlier this year at the Delfasco Forge site in Grand Prairie, TX, to address trichloroethene (TCE) vapor migrating from a groundwater plume. Region 6 and the State had determined after extensive site investigations that technologies such as soil vapor extraction or natural attenuation would require several years to remove or reduce the plume ...

  • Catalytic Exhaust Emission Control of Small Internal Combustion Engines

    ABSTRACT Gaseous emissions present in the engine exhaust of on-road motor vehicles are subject to stringent exhaust emission 2ontrol standards for carbon monoxide (CO), hydrocarbons, and ...


    By DCL International Inc.

  • Sulfur Compounds Analyzer MEXA-1170SX

    The MEXA-1170SX is a continuous gas analyzer for sulfur compounds existing in engine emissions. It can measure SO2 concentration and the amount of total reduced sulfur compounds (TRS), such as H2S, separately. It can also measure the total sulfur compounds (TS) that contains both gaseous compounds and liquid compounds in PM, such as SO3. By utilizing ultra-violet fluorescence (UVF) method and ...


    By HORIBA Europe GmbH

  • Hydrogen Chloride Analyzer (HCl, H2O)

    LGR's Hydrogen Chloride Analyzer (HCl, H2O) provides sensitive measurements of HCl in ambient air or in industrial process flows (e.g., coal and cement exhaust streams) with extremely high precision and sensitivity. No longer do you have to spend a lot of money or wait a long time to measure HCl with extremely high sensitivity – LGR's HCl Analyzer provides measurements every second with ...

  • New Filtration Systems for the Control of Exhaust Emissions from Light-Duty Diesel Engines

    The paper includes the design, installation and testing of two different diesel particulate filter systems for light-duty diesel engines. The systems were installed on mining vehicles at Kidd Creek Mine in ...


    By DCL International Inc.

  • Low-mass PM analyzer MEXA-1370PM — Improvement of the Performance for PM Composition Analysis —

    Particulate matter (PM) emitted from engines is currently measured by the filter weight method. The filter weight method passes diluted emission gases through a filter collecting the PM, and post test weighs the mass of the collected PM on a precision balance. However, this method is time consuming, and with decreasing PM emission volumes, improvements in accuracy were needed. So the MEXA-1370PM ...


    By HORIBA Europe GmbH

  • Portable IR Analyzer Provides ASTM Field Test Method for Measuring Soot Levels In Diesel Engine Lubricating Oils

    The InfraCal Soot Meter, from Wilks Enterprise, gives users an approved ASTM testing method for measuring the percent level of soot in diesel engine lubricating oils -- ASTM Method D7686-2011 entitled “Test Method for Field-Based Condition Monitoring of Soot in In-Service Lubricants Using a Fixed-Filter Infrared (IR) instrument.” While there is widespread disagreement on used-diesel ...


    By Spectro Scientific

  • Comparing TGA, FTIR and fixed filter infrared analyzers for measuring soot levels in in-service lubricants

    Measuring soot in diesel engine oil has become more important as soot levels get higher due to exhaust gas recirculation. As soot isone of the key indicators for the condition of the oil, diesel engine maintenance programs performing regular soot checks can realize cost savings by extending drain periods and reducing used oil disposal. TGA (Thermal Gravimetric Analysis) is the traditional method ...


    By Spectro Scientific

  • Thank You All for the Success of MEXA-7000

    The MEXA-ONE, our new Motor Exhaust Gas Analyzer launched in 2012, has become our core product superseding the MEXA-7000 with a surge in the number of shipments since the beginning of 2014. The MEXA-7000 had evolved continually over the nineteen years since its introduction in 1995 to respond to the significant changes that took place in emission regulations, types of fuel and new technology in ...


    By HORIBA Europe GmbH

  • Recuperative Thermal Oxidizers for Coffee Roasting

    Coffee Roasting Company Epcon has extensive experience in designing and building Recuperative Thermal Oxidizers for the Coffee Roasting Industry. The Problem A leader in the Coffee Industry needed equipment to control odor and eliminate VOC's from Coffee Roasting. The company went out seeking the technical solutions and went to several manufacturers to ...


    By Epcon Industrial Systems, LP

  • Case study: Regenerative thermal oxidizers for coffee roasting

    Epcon has extensive experience in designing and building Regenerative Thermal Oxidizers (RTO's) for the Coffee Roasting Industry. The Problem A leader in the Coffee Industry needed equipment to control odor and eliminate VOC's from Coffee Roasting. The company went out seeking the technical solutions and went to several manufacturers to locate the best possible technology. ...


    By Epcon Industrial Systems, LP

  • Case study - Air-to-air heat exchanger provides plant heat and big savings

    OVERVIEW A food processing facility installed a new Regenerative Thermal Oxidizer (RTO) for odor control from its roasting operation.  The oxidizer was designed for 95% thermal rate of efficiency and included supplemental fuel injection (SFI) which is used during low VOC loading conditions, to help save fuel cost.  The customer was looking at additional ways  to further ...

  • Reaching Euro VI emissions limits

    The requirements of low and lowest detectable exhaust analysis has prompted Eco Physics to launch a broad range of analyzers for NO/NOx detection. Emissions tuning is one of the targets of the EURO VI regulations as well as US EPA 2010, which are: Reduction of Particulate Matter (PM) and reduction of Nitrogen Oxides (NOx). In the past 15 years – since the first European regulation for exhaust ...


    By ECO PHYSICS INC.

  • Effects of a zeolite SCR system on comprehensive emissions from a heavy-duty diesel engine

    The effects of a zeolite urea-selective catalytic reduction (SCR) aftertreatment system on a comprehensive spectrum of chemical species from diesel engine emissions were investigated in this study. Representative samples were collected with a newly developed source dilution sampling system after an aging process designed to simulate atmospheric dilution and cooling conditions. Samples were ...

  • In-situ investigation of the cathode catalysts for PEM fuel cells using differential electrochemical mass spectrometry

    Differential electrochemical mass spectrometry (DEMS) involves applying a potential across an electrochemical cell and measuring the resulting current while concurrently analyzing gas products with a mass spectrometer. We used DEMS to investigate the mechanism of carbon support corrosion (CSC) in-situ at the cathode of proton exchange membrane fuel cell (PEMFC). The cathode exhaust gases were ...


    By Hiden Analytical

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Ammonium removal from aqueous solutions by zeolite adsorption together with chemical precipitation

    The aim of this study was to remove ammonium from aqueous solution and recycle ammonium. Ammonium removal from aqueous solution by natural and pretreated zeolites, breakthrough curve, chemical regeneration of pretreated zeolite, ammonium removal from regeneration solution by chemical precipitation and NH4+ adsorption isotherms were investigated by conducting a series of batch and continuous ...


    By IWA Publishing

  • A cost-effective method for controlling compost air emissions

    In October 2007, ECS began conducting trials at California State University Fresno (CSUF) to explore using the new patent pending AC Composter (ACC) covered aerated static pile system to manage dairy manure solids and comply with airquality standards. A two-zone portable pilot system was delivered by ECS and installed at the CSUF research dairy. This research is being conducted under a Phase I ...

  • New technology for municipal scale compost operations

    There is a new facility located in Ontario, Canada that accepts construction and demolition waste (C&D) and 100,000 TPY of source separated organics (SSO) waste. The owners chose a new non-thermal plasma (NTP) system to control the odor in its 120,000 cubic feet of air per minute (CFM) air emissions. This NTP system is very compact, fits easily on a platform, is configured as a number of ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you