exhaust stack Articles

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Controlling Stack Emissions in the Wood Products Industry

    Electrostatic precipitation has been a reliable technology since the early 1900's. Originally developed to abate serious smoke nuisances, the manufacturers of zinc, copper, and lead quickly found electric gas cleaning a cost efficient way to recover valuable product carried out of the stacks from furnace operations. Today electrostatic precipitators are found mainly on large power plants, cement ...


  • Case study - Engine cell exhaust: Catalytic oxidizer

    Overview Endurance testing of outboard motors for boats has typically been done in lakes and sometimes on barges. This testing was time consuming, presented logistic problems and removed the testing from the R & D department and the factory. When a company in Oklahoma decided to build their own endurance test cell area, the Environmental Protection Agency required them to control the ...

  • Fort Stewart uses custom stainless steel stacks for M-1 tanks

    Monoxivent provided six custom exhaust stacks made of 11-gauge 304 stainless steel for Fort Stewart (GA). The 24" diameter stacks are used to remove harmful exhaust fumes from the facility.  Special adapters were fabricated to attach to M-1 Tanks.  1000 Series Stainless Steel flex hose tied the tank adapters to special wall receptors attached to the vertical ...


    By Monoxivent

  • The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe

    POLLUTION S.r.l. manufactures POLARIS FID analyser, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Electrochemical Exhaust Gas Purification - SAE technical paper series

    This text is divided into Iwo parts; the first part gives a short recapitulation 01 the development status 01 the eiectrochemical reactor lor soot removal, while the second part gives a description 01 activities on electrochemical NOx reduction. The Electrochemical Reactor lor filtration and continuous combustion 01 soot lrom diesel exhaust gas has been described earlier [1, 2]. The reactor size ...


    By Dinex A/S

  • An analysis of extinction coefficients of particles and water moisture in the stack after flue gas desulfurization at a coal-fired power plant

    Two important factors that affect in-stack opacity—light extinction by emitted particles and that by water moisture after a flue gas desulfurization (FGD) unit—are investigated. The mass light extinction coefficients for particles and water moisture, kp and kw, respectively, were determined using the Lambert-Beer law of opacity with a nonlinear least-squares regression method. The ...

  • Turning down the heat - Innovation Magazine

    Although not the main contributor on a global scale, combustion by industry has been associated with localized high volume and high concentration sources of CO2 emissions. This is especially true for industries characterized by high energy consumption such as the pulp and paper, chemical, gas and petroleum, steel and mineral processing industries. In addition, the high exhaust temperatures of ...


    By Inproheat Industries Ltd.

  • Pet Crematorium - Bespoke pet cremation facility - Case Study

    TodaySure have installed numerous pet crematoria, throughout the World. Our most recent innovative design incorporated two stacked individual pet cremators, fuelled by the exhaust gases of the adjacent automatically loaded mass burn unit, thus minimising fuel input and reducing carbon ...


    By Todaysure Limited

  • XL oversized hose reels installed at Ft. Lee

    Monoxivent has produced 82 XL oversized exhaust hose reels for Ft. Lee (Virginia).  The reels are used to provide a clean air environment for the US Military in a maintenance facility for oversized military vehicles.  The reels are offered with 24" and 36" diameter drums and are between 3' and 7' in width.  The largest reel holds 60' of 18" diameter high-temperature exhausting ...


    By Monoxivent

  • Case study - Oxidizer energy recovery options

    Overview The mainstream media today is full of allusions to energy awareness and conservation. Just as visible these days are media references to astronomical dollar figures that can boggle the mind. This article does not seek to break out of that mold, but rather to conform to it – as Oxidizer Stack Heat Recovery offers a tremendous opportunity for both energy conservation and ...

  • Oxidizer operating cost reduction strategies

    The mainstream media today is full of allusions to energy awareness and conservation. Just as visible these days are media references to astronomical dollar figures that can boggle the mind. This article does not seek to break out of that mold, but rather to conform to it – as Oxidizer Stack Heat Recovery offers a tremendous opportunity for both energy conservation and energy cost reduction. ...

  • Don´t Let Your Energy Go Up In Smoke

    Competitive pressures and unpredictable energy costs continuously motivate us to examine our processes for opportunities to increase quality and productivity, and to decrease costs. Energy-intensive processes such as those associated with the manufacture of a wide variety of  products utilizing water or VOC-based solvents offer opportunities to reduce operating costs through heat ...


    By Babcock & Wilcox MEGTEC

  • Case study - Seattle food processing plant naturally destroys odors while creating natural products

    Challenge: A food processing company in Seattle was experiencing odor problems while processing food scraps into a natural liquid fertilizer. The odors were coming from exhaust stacks during the final stages of fertilizer production. Located in an industrial/commercial area in close proximity to other facilities, the}' needed a solution to stop odor complaints from their neighbors. ...


    By OMI Industries (OMI)

  • EIS Safety First - Case Study

    EIS was invited by a UK company to provide a fully automated VOC / odour abatement system treating the exhausts from multiple processes and needing multiple safety systems.  The abatement plant would be part of the construction of a new factory based in Scotland, so the timing and installation of the system would be critical to the plant coming on stream at the planned date. The production ...

  • Case study - Waste heat generates steam and savings

    OVERVIEW A coil coating facility purchased a new a 15,000 SCFM Regenerative Thermal Oxidizer (RTO) which had a nominal heat transfer efficiency rate of 90% thermal energy recovery. It was designed with supplemental fuel injection (SFI) which is used during low VOC loading conditions, to help save fuel cost.  The facility was looking for additional ways to decrease their exhaust ...

  • Municipal sewage treatment plant eliminates odors and saves money versus its previous treatment scheme

    The Problem - Neighbors on the surrounding hillsides of this Northeastern Ohio sewage treatment plant were outraged by constant, intensely offensive odors from the plant's sludge drying operations. The plant's current treatment was providing only marginal success in controlling odors pouring from the exhaust scrubber. The plant was receiving hundres of calls a week. The ...


    By Benzaco Scientific, Inc.

  • Case study - Air-to-water heat exchanger reduces operating costs by $120,000 per year

    OVERVIEW This pharmaceutical company had a 5,000 SCFM oxidizer that they were looking to relocate to another facility across the United States.  The destruction rate efficiency and heat recovery expectation at the new location differed from the original design conditions at the current facility. ACTION An Anguil field service engineer went to ...

  • Characterisation for some emission sources in CMB calculation for Mae Moh area, Thailand

    Particulate samples of agricultural waste burning, straw burning, forest leaf burning, heavy duty truck emission, paved road dust, soil, agricultural soil, coal, electrostatic precipitator ash, and emission from stack power plant were collected from the Mae Moh area. Chemical compositions of sampling filters were analysed to determine the particulate matter source profiles. The analysis included ...


    By Inderscience Publishers

  • Theory, Modeling, and Measurements of Gas Plumes

    Abstract Spectroscopic measurements of infrared CO2 transitions in gas plumes are reported, and evaluated for their potential to yield a reliable remote sensing technique for determination of plume temperature. Measurements were made on two types of plumes: a sideways-directed plume from a vehicle exhaust, and a stack plume from a propane-burning portable plume generator. Modeling of CO2 ...


    By D&P Instruments

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you