fid-based gas analyser Articles

  • Gas analysers support management of Swindon fire

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents. Arrangements have been made in England to bring together experts from the Environment Agency ...


    By Quantitech Ltd

  • FTIR resolution requirements for industrial gas analyses

    FTIR Spectroscopy FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epitreatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D faciltities, FTIR is applied to combustion ...


    By CIC Photonics, Inc.

  • Analysis of Natural Gas Products by GC / TCD / FID

    The complex mixture of condensible hydrocarbons and permanent gases in a natural gas product has historically been separated on gas chromatographs equipped with dual columns and a switching valve. The light gases are separated from heavier compounds on a molecular sieve column, which is then backflushed onto a suitable column to separating the rest of the mixture. The Buck Scientific Model 910 ...


    By Buck Scientific Inc

  • Multiple gas impurity analyses and verification for semiconductor process tools

    With the increased emphasis on the purity of cleaning, etching and treatment gases by the semiconductor industry, advanced analysis instrumentation is required to monitor the electronic specialty gases and to verify the performance of process tools and components. This paper describes new instrumentation and software specifically designed to accomplish ppb level gas analyses in times as short as ...


    By CIC Photonics, Inc.

  • Determination of TOC in stack through the innovative FID analyser easy to carry - Case Study

    PROBLEM: The industrial chimney's emissions of Volatile Organic Compounds (VOCs) are becoming issues of global importance and to have an accurate knowledge about how to test VOC turns into a strategic issue. VOC emissions are quantified and monitored according to standard EN 12619, using FID analyzer which uses hydrogen and other reference gases in ...


    By Pollution Srl

  • Analysers and next generation SRU control

    The history of on-line process analytics is a relatively short one. Development was driven by the need for process control of high value hydrocarbonbased products. The first on-line analyser applications came during the second war. Rapid development came in the 1970s with the advent of the microprocessor and resultant chemometric techniques. Led by Phillips Petroleum, Union Carbide and Dupont ...

  • Emissions analyser helps manage power station

    A multiparameter emissions monitor at Thetford power station is being used to demonstrate to the Environment Agency that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Milton Keynes based Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are ...


    By Quantitech Ltd

  • Technical and economic analyses of a hydrogen-fed gas turbine with steam injection and co-generation

    Enel has been working on a hydrogen programme dealing with both hydrogen production and uses. The first phase deals with a hydrogen-fed, gas turbine-based co-generative cycle, in which steam injection in the gas turbine itself is adopted in order to couple high process efficiencies with very low nitrous oxide emissions. This paper presents the main results of the co-generative cycle thermodynamic ...


    By Inderscience Publishers

  • Improved derivatization protocol for simultaneous determination of alkylphenol ethoxylates and brominated flame retardants followed by gas chromatography-mass spectrometry analyses

    An improved derivatization protocol for the simultaneous determination of alkylphenol ethoxylates and brominated flame retardants with heptafluorobutyric anhydride under triethylamine amine base was investigated. The derivatization reaction was completed in 30 min at 50 °C using hexane as solvent. Under these conditions, it was observed that alkylphenol ethoxylates and tetrabromobisphenol ...


    By IWA Publishing

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Thermodynamic performance simulation of a coal gasification and SOFC based combined cogeneration plant by energy and exergy analyses

    This paper presents a thermodynamic model of a combined cogeneration plant that employs a coal gasifier, a gas cooler and a solid oxide fuel cell (SOFC) upstream of the gas turbine and a downstream HRSG to generate process steam at low pressure. Simulated performance of the plant with respect to variations in some design and operating parameters has been reported. While energy analysis indicates ...


    By Inderscience Publishers

  • Energy and exergy analyses of a steam reforming process for hydrogen production

    Hydrocarbon steam reforming is an important process for hydrogen production. In petroleum refineries, steam reforming is most commonly used for hydrogen production from naphtha and light hydrocarbon gases (methane, ethane and propane). Since the hydrocarbon steam reforming system is one of the highest energy intensive systems in a petroleum refinery it should be directed to a more efficient use ...


    By Inderscience Publishers

  • FTIR emissions analyser helps manage UK power station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Quantitech Ltd

  • FTIR Emissions Analyser helps manage UK Power Station

    A Gasmet FTIR multiparameter emissions monitor at Thetford power station is being used to demonstrate that the plant is performing within the conditions of its environmental permit. However, the data from the analyser, which was supplied by Gasmet’s UK distributor Quantitech, also performs a vitally important role in helping to manage the plant. “Individual gas readings are displayed ...


    By Gasmet Technologies Oy

  • The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe

    POLLUTION S.r.l. manufactures POLARIS FID analyser, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Fixed price contract versus incentive–based contract in the oil and gas industry

    The research question of this paper is to analyse when an operator and a service provider prefer a fixed price contract, common in the oil and gas industry, versus the uncommon incentive–based contract. The contracts are modelled with 20 parameters and one free choice variable which is the time to complete the project determined by the service provider. The method is to determine the ...


    By Inderscience Publishers

  • Fixed price contract versus incentive-based contract in the oil and gas industry

    Abstract: The research question of this paper is to analyse when an operator and a service provider prefer a fixed price contract, common in the oil and gas industry, versus the uncommon incentive-based contract. The contracts are modelled with 20 parameters and one free choice variable which is the time to complete the project determined by the service provider. The method is to determine the ...


    By Inderscience Publishers

  • The NILU tracer gas technique

    A tracer gas technique has been developed by the Norwegian Institute for Air Research (NILU) to study emission rates, dilution and diffusion of gases. The technique has been applied in several countries to quantify diffuse VOC leakages from refineries, petrochemical plants and oil production platforms.  The tracer gas techniqueThe dual tracer gas system developed by NILU has been applied in ...

  • Advanced gas analysis - on the go

    The field of ambient air analysis - monitoring industrial and other environments for harmful concentrations of gases - has traditionally faced a technology limitations: Would you prefer a complete and reliable tool, which will be bulky, complicated and inconvenient? Or would you like a nice portable one that's simple and lightweight, but unreliable and limited in its capability? Truly complete ...


    By HHCS Handheld USA Inc.

  • Gas flow control method of recycling gas drilling technology

    Recycling gas drilling is a new drilling technology. The paper based on the theory of gas transient flow, a set of theoretic models of gas flow control at the export of annulus are set up in combinations of the principles of the seepage flow mechanics and the characteristics of recycling gas drilling technique. According to the basic laws which the flowing gas should comply with, the properties ...


    By Inderscience Publishers

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you