fid instrument Articles

  • Direct Mass Flow or Volumetric: The Thermal Flow Meter Technology Advantage!

    In today’s world where everyone is watching the bottom line, you need high performance, cost-effective instrumentation—and capillary thermal mass flow meters and controllers have been proven to meet this criteria in a wide range of process applications. Thermal mass flow technology is an industry standard for mass flow control of gases because it measures flow directly, at the ...


    By Sierra Instruments, Inc.

  • The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe

    POLLUTION S.r.l. manufactures POLARIS FID analyser, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Determination of TOC in stack through the innovative FID analyser easy to carry - Case Study

    PROBLEM: The industrial chimney's emissions of Volatile Organic Compounds (VOCs) are becoming issues of global importance and to have an accurate knowledge about how to test VOC turns into a strategic issue. VOC emissions are quantified and monitored according to standard EN 12619, using FID analyzer which uses hydrogen and other reference gases in ...


    By Pollution Srl

  • Understanding Oil-in-Water Instrument Specifications

    The measurement capabilities of oil-in-water analysis methods are described by several analytical figures-of-merit. Examples are: Range (Linear and Dynamic) Limit of Detection (LOD) Limit of Quantification (LOQ) Precision (Repeatability and Reproducibility) Sensitivity Accuracy Response Time Some or all of these are often specified by customers in the bid packages issued when selecting a ...

  • Why instrument hire makes occupational safety sense

    Background Decisions concerning the acquisition of occupational safety monitoring instrumentation are often made by operational staff that may not have visibility of the full financial implications of their choices. The following article will examine the factors affecting these decisions and explain why a strategic decision to hire instrumentation can deliver substantial and wide-ranging ...


    By Ashtead Technology Ltd

  • Texas Instruments - A Novel Separation Technique for the Analysis of Trace Levels of Atmospheric Contaminants in Inert Semiconductor Process Gases

    A NOVEL SEPARATION TECHNIQUE FOR THE ANALYSIS OF TRACELEVELS OF ATMOSPHERIC CONTAMINANTS IN INERTSEMICONDUCTOR PROCESS GASES J. Scott McWilliams, Alan Johnson, Charlene Long, Jeremiah D. Hogan*Texas Instruments, Inc.Dallas, TX 75265 Low ppb detection limits for contamination in cylinder gases have been achieved with gas chromatography using a modified gas ...


    By Environics, Inc.

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Analyzing for Trace CO and CO2 using a Total Hydrocarbon Analyzer

    Untitled Document The purity of Specialty Gases is determined by the measurement of various contaminants including Total Hydrocarbons. Low level measurements of carbon ...


    By MOCON, Inc. - Baseline

  • Case study - Canada crude oil sites

    The Canadian Council of Ministers of the Environment requires laboratories to use the CCME’s Petroleum Hydrocarbon (PHC) Method, where GC-FID instrumentation is used to report VPH and EPH hydrocarbon fractions. Sitelab’s popular Extended Diesel Range Organics (EDRO) test typically detects hydrocarbons in the C10 to C36 carbon range, but the UVF will pick up heavier compounds up to ...


    By Sitelab Corporation

  • Success story: How we solved the bench space equation in a lab!

    Problem Overview Nowadays laboratories are equipment intensive and require as much bench space as possible. Recently, our company has being challenged by a lab manager of a primary Italian food industry to find a solution for his saturated lab bench. Among several devices, about 13 GC-FID’s are working with several gas generators. The initial choice for having on-site gas ...


    By LNI Swissgas

  • Are your field soil screening procedures providing you with practical and accurate information?

    Untitled Document Environmental consulting activities frequently require that on-the-spot decisions be made in the field concerning the ...


    By Enviro-Equipment, Inc.

  • All in One Unit for GC Applications

    Leman Instruments is a leading European company, specialised in standard products, OEMs and in custom designed realisations involving high purity H2, N2, zero air, combined solutions for FIDs, GCs, purge air generators, CH4 & CO2 scrubbers, N2 and multigas for LCMS with high level of communications involving Ethernet, USB, RS 485 and ...


    By Leman Instruments SAS

  • Chromatotec Sponsor of the 2015 International Symposium on Polycyclic Aromatic Compounds (ISPAC)

    PAH monitoring being at the core of Chromatotec’s 2015 R&D strategy, it was an evidence for the group to sponsor the annual edition of ISPAC, which took place in Bordeaux from 13 to 17 September. This international conference brought together researchers worldwide and focused on the research of Polycyclic Aromatic Compounds (PACs) on multiple ...


    By Chromatotec Group

  • TVOC measurement for LEED/green building evaluation

    Total Volatile Organic Compounds (TVOC) may be evaluated when building designers/managers are pursuing the Leadership in Energy and Environmental Design Green Building Rating System for New Construction (LEED-NC) EQ Credit 3.2. The latest LEED-NC guidance document specifies that the maximum allowed concentration of TVOC measured in a building (post construction, pre-occupancy) is 500 µg/m3; the ...


  • Building on a legacy of PID development

    Summary From the 1970s to the present day, photo-ionisation detectors (PIDs) have been at the front line of efforts to detect volatile organic compounds. As industrial hygiene has become ever more important and exposure limits for VOCs have reduced, PID technology has continued to develop, providing reliable detection under challenging environmental conditions at concentrations right down to ...


    By Ion Science

  • Innovations in Bench Testing of Waste waters

    Wastewater management in developing countries throughout the world is in a state of crisis. It is estimated that 2.6 billion people worldwide live without adequate sanitation. Resources are scarce, previous management systems have failed, and traditional techniques and solutions are not immediate enough, too expensive, or simply inefficient. Discussion with regards to OI Analytics Instrumentation ...


  • Chromatography Tips

    No.1 Gas Chromatography Tips  Our Founders and engineers of the company had accumulated more than 60 years experience in the research and development of HPLC instrumentation; HPLC column technology; mass spectrometer installation, training and services; chemical and biochemical separation, detection and quantification, Proteomics and cancer biomarker research and ...


    By AcuTech Scientific Inc.

  • Energy Savings on Process Heating Units Case History

    The Customer This specialty chemical company is a leading supplier of performance polymers. Their products are used in a wide range of applications including adhesives, coatings, consumer and personal care products, sealants, lubricants, medical, packaging, automotive, paving, roofing and footwear products. The Project The company was increasing the ...

  • Detailed characterisation of essential oils by flow-modulated GC×GC and Tandem Ionisation mass spectrometry

    Volatile oils of plants, also known as essential oils, have been used for many years for their flavour, fragrance and medicinal properties. However, their extreme complexity and diversity presents analysts with a significant challenge when it comes to quality control. They are generally composed of monoterpenes and sesquiterpenes, as well as their oxygenated derivatives, such as aliphatic ...


    By SepSolve Analytical

  • Designing and Implementing Perimeter Air Monitoring Programs

    Perimeter or fenceline ambient air quality and meteorological monitoring programs have become increasingly valuable at hazardous waste, landfill, dredging, ports, and MGP remediation sites. Air quality monitoring programs protect public health and reduce owner liability ...


    By AECOM

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you