field gas chromatograph Articles

  • A Portable High Speed Gas Chromatograph for Field Monitoring

    Over the last two decades a variety of portable or transportable gas chromatographs (GC) have been specifically designed for field use. Each instrument has introduced innovations that have simplified the task of on site air monitoring. Portable instrument users are well aware of the advantages of field sampling. These advantages include more representative results because there is no sample ...


  • BTEX monitor, equal performances to laboratory chromatographs

    Environnement S.A leveraged its technical leadership in this field with an extensive experience, being one of the first companies creating its first BTEX analyser almost 20 years ago. The VOC72M third generation of ...


    By Environnement S.A

  • The NILU tracer gas technique

    A tracer gas technique has been developed by the Norwegian Institute for Air Research (NILU) to study emission rates, dilution and diffusion of gases. The technique has been applied in several countries to quantify diffuse VOC leakages from refineries, petrochemical plants and oil production platforms.  The tracer gas techniqueThe dual tracer gas system developed by NILU has been applied in ...

  • Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas

    This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three ...


    By Ogawa & Company, USA, Inc.

  • Environics - Reducing calibration gas cost by up to 60%

    EPA's appendix 'M' 40 CFR 51 reduces calibration gas cost by 60%By: Terrence P. Dunn, President of EnvironicsOn May 30, 1995, the EPA published the final version of Method 205 for inclusion in Appendix M of 40 CFR Part 51 entitled, 'Verification of Gas Dilution Systems for Field Instrument Calibrations.' Continuous emissions monitoring systems (CEMS) require ...


    By Environics, Inc.

  • Gas cell selection for analysis of electronic gases

    APIMS and FTIR remain the preferred analytical tools for monitoring impurities in the electronic  specialty gases used by the semiconductor industry, although other tools such as CRDS are currently finding application in selected cases. FTIR spectroscopy offers the advantage of the simultaneous measurement of all gaseous species that exhibit dipole moment changes during vibrations at ...


    By CIC Photonics, Inc.

  • Low thermal mass gas chromatography – Analysis at MACH speed

    Gas Chromatography (GC and GC/MS) analysis has been the mainstay for the analysis of regulated organic contaminates in the environmental field. Numerous advancements have occurred in GC instrumentation that include improvements for injectors, detectors, automation, software, and GC column choices. Although many advancements have been made in GC technology, very little has changed for column oven ...


  • Praxair Selects Baseline-MOCON’s New BevAlert Gas Analyzer To Improve Detection Sensitivity Of CO2 Impurities

    Lyons, CO — Praxair, Inc. has upgraded its carbon dioxide (CO2) gas analysis with the installation of multiple BevAlert™ Model 8900 at its plants across North America and select international locations.The BevAlert Model 8900 new gas chromatograph, from Baseline-MOCON, Inc., a subsidiary of MOCON monitors trace impurities in CO2 (and other gases) while setting new standards for analytical ...


    By MOCON, Inc. - Baseline

  • System Description for Monitoring Volatile Hydrocarbons

    To help build a comprehensive Industrial Hygiene program, Buck Scientific introduces the IH910 vapor monitoring system utilizing our model 910 gas chromatograph and IH300 air sampling train. Designed to analyze hydrocarbons in air, such as degreasing solvents and paint vapors emitted during plant operations, the IH910 penetrates the 1mg/m3 detection barrier erected by other field portable gas ...


    By Buck Scientific Inc

  • Detection and measurement of GWGs in semiconductor fab facilities

    Problem Statement Various processes and tools in the modern wafer fab plant produce effluent streams that contain unacceptably high levels of perfluorocarbon GWGs (greenhouse warming gases). These effluent streams are abated by plasma incineration and wet scrubbers and other techniques. It is necessary to measure the destruction removal efficiency (DRE) of the various abatement methods ...


    By CIC Photonics, Inc.

  • Real Time Measurments of Acetylene in Ethylene Manufacturing Process

    Keywords Tunable Diode Laser, Wavelength Modulation Spectroscopy, Analyzer, Acetylene, Ethylene, Acetylene Converter Abstract The analyzer, based on near infrared Tunable Diode Laser Absorption Spectroscopy (TDLAS), was developed for the measurement of acetylene in process streams. Measurements of acetylene were made as under laboratory conditions and in ...

  • Analysers and next generation SRU control

    The history of on-line process analytics is a relatively short one. Development was driven by the need for process control of high value hydrocarbonbased products. The first on-line analyser applications came during the second war. Rapid development came in the 1970s with the advent of the microprocessor and resultant chemometric techniques. Led by Phillips Petroleum, Union Carbide and Dupont ...

  • Texas Instruments - A Novel Separation Technique for the Analysis of Trace Levels of Atmospheric Contaminants in Inert Semiconductor Process Gases

    A NOVEL SEPARATION TECHNIQUE FOR THE ANALYSIS OF TRACELEVELS OF ATMOSPHERIC CONTAMINANTS IN INERTSEMICONDUCTOR PROCESS GASES J. Scott McWilliams, Alan Johnson, Charlene Long, Jeremiah D. Hogan*Texas Instruments, Inc.Dallas, TX 75265 Low ppb detection limits for contamination in cylinder gases have been achieved with gas chromatography using a modified gas ...


    By Environics, Inc.

  • Bringing Bangladesh to World Bank standards - A case study on satisfying the criteria of the World Bank requirements in Bangladesh

    Client: Cairn Energy and Halliburton Brown & RootConsultant: Andy IveNaturally when the World Bank was asked to finance the first offshore platform in Bangladesh in 1994 they demanded stringent environmental protection. What was needed was someone who could combine engineering practicalities with legislative requirements to ensure environmental compliance. Andy Ive was called in to ...


    By Ive Design

  • Triad expedites brownfields redevelopment in Fairbanks

    The Fairbanks North Star Borough (FNSB) used Triad in 2006-2007 to assess environmental conditions at a municipal property along the Chena River in Fairbanks, AK. FNSB accelerated the site investigation as part of a brownfields assessment grant received from the U.S. EPA in 2005. Low-level contamination had been identified onsite in past investigations, but its extent and impact on future ...

  • Target GC-MS Analysis using Accelerated Column Heating and Interactive Deconvolution Software

    In diverse fields ranging from environmental samples to complex fl avor preparations, high performance, high resolution capillary gas chromatography/mass spectrometry, GC-MS, has become the preferred technique for identifying and quantifying target compounds at trace levels. Many of these samples are characterized by very complex matrices, which provide a substantial challenge for contemporary ...


  • Comply with Highly Regulated Oil in Water Measurements Using Portable Infrared Analyzers

    The Petroleum Industry – both offshore and onshore -- has regulations that limit the amount of oil in discharged water.  Fixed filter infrared (IR) analyzers have been used to test oil levels in produced water on drilling platforms for over 45 years for a number of reasons. On oil rigs where real estate is at a premium, infrared analyzers such as the Wilks InfraCal TOG/TPH ...


    By Spectro Scientific

  • A novel spectrometer design for process and handheld infrared spectral measurements

    Introduction Infrared spectroscopy offers many unique advantages for measurements within an industrial environment. Historically, the technique has been used for a broad range of applications from the composition of gas and liquid mixtures to the analysis of trace components for gas purity analysis. In cases where a well-defined method of analysis is involved, such as the measurement of ...


    By CIC Photonics, Inc.

  • Performance-Based Measurement Systems

    Many of the Environmental Protection Agency's (EPA's) methods used to monitor air, water and soil for environmental contaminants prescribe step-by-step details on how the chemical analysis must be conducted and prohibit any deviations or variations. The EPA has recognized that monitoring equipment and technology have improved tremendously over the last few years; that environmental media do not ...


    By WSP | Parsons Brinckerhoff

  • Is Microflow LC a Reality or Perception?

    Microflow or nanoflow chromatography has been used mostly in the academic and fundamental research environment in the past for its various advantages over analytical liquid chromatography, but rarely in the industrial settings. This is most likely because many of us believe it is a pain-in-the-neck technique to perform! But is this a reality or just a ...


    By Waters Corporation

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you