filter press plate Articles

  • Diazinon plate statfax 303+ program set-up

    General Comments: This technical bulletin is a guide for the installation of the Diazinon Plate Kit Protocol onto the StatFax 303 Plus Microwell photometer. Please refer to the StatFax 303 Plus User’s Manual for detailed instructions. Bold lettering indicates the StatFax screen display. [Brackets] denote keys. Protocol: 1. Turn on the StatFax 303 Plus. ...


  • Microcystins plate statfax 303+ program set-up

    General Comments: This technical bulletin is a guide to the installation of Microcystins Plate Kit Protocol into the StatFax 303 Plus. Please refer to the StatFax 303 Plus Manual for detailed instructions. Bold lettering indicates the StatFax screen display. Protocol 1. Turn on the StatFax 303 Plus. 2. Press the [MULT] key on the keypad. 3. Regression ...


  • Solvent Recovery System Keeps Presses Rolling at World`s Largest Gravure Printing Plant

    When QUAD/GRAPHICS Inc. entered the publication gravure printing market, it followed the axiom of Daniel Burnham, the 19th century architect and urban planner, to 'make no small plans.' In 1985, the Pewaukee, Wis.-based printing company purchased two 96-inch web, eight-color, high-speed presses and installed them at its new printing plant in Lomira, Wis., near Milwaukee. Conventional wisdom at ...

  • Wastewater from metal finishing industry set for more regulation from the Environmental Protection Agency

    The U.S. Environmental Protection Agency (EPA) recently released its preliminary 2014 Effluent (liquid waste or sewage discharged into a river or sea) Guidelines Program, which outlined more regulations for wastewater from those within the metal finishing industry. A filter press has been a long-trusted solution for treating metal waste, even for those applications that are difficult to dewater. ...


    By M.W. Watermark LLC

  • Case Study: Heavy Industrial Laundry

    This facility washes heavily soiled towels from the ink printer and furniture polishing industries. The wastewater generated is very concentrated with metals and hydrocarbons making it difficult to treat in their DAF pretreatment system. The facility was using conventional chemistry with sulfuric acid, organic/inorganic coagulant, metal precipitant,flocculant, and Harborlite (filter press ...


    By Integrated Engineers Inc.

  • Metal finishing - Columbia manufacturing company - case study

    Application Columbia Manufacturing Company of Westfield, Massachusetts began producing bicycles in 1877. The company, while still producing bicycles, transitioned its core product line to institutional furniture with chrome plated bases made from tubular steel. Large amounts of potable water were required for the old plating system. The company was using 180,000 gallons of potable water a ...


  • Corrugated Printing Facility Zero Discharge

    This company imports corrugated board and prints the labels using a flexographic machine. The facility had a wastewater treatment system using the traditional liquid chemistry of aluminum chloride, caustic for pH adjustment, and an anionic flocculant. The effluent was often out of compliance due copper from the color pigments in the inks. The system required continual adjustment of the 3 ...


    By Integrated Engineers Inc.

  • Corrugated Sheet Plant

    The previous wastewater treatment was composed of the following chemicals: an acidic coagulant, caustic for pH adjustment, and an anionic polymer made down to 1% solution. The facility used 3-4 gallons of coagulant, 2-3 gallons of caustic, and 2-3 gallons of anionic flocculant (at a 1% solution) at a cost of $50/batch. The operator stated that they had low solids, they tended to overdose which ...


    By Integrated Engineers Inc.

  • Integrated Engineers Case Study: Circuit Board Manufacturer

    A circuit board manufacturer in southern California was not able to achieve the discharge levels of copper and nickel with their existing system of coagulant, anionic and cationic flocculants and metal precipitant treatment process followed by lamella plate clarification. The previous treatment process developed a settled sludge that had poor shear characteristics and required further coagulant ...


    By Integrated Engineers Inc.

  • Hazardous Oily Water Treatment Facility

    Wastewater Treatment Success Stories Hazardous Oily Industrial Waste Water Treatment The sample was received was at a pH of 6.8 and did not require any pH adjustment. 100 ml of the sample was tested and dosed with 0.4 ...


    By Integrated Engineers Inc.

  • Industrial Laundry

    Problem: For many years industrial laundries discharged their effluent into the local sanitation plant without any restrictions. Now, when applying for a new discharge permit, the laundries are required to meet the new guidelines established by the EPA These requirements are normally as follows: 100 PPM for fats, oils and greases; and 250 PPM for total suspended solids. Some ...


    By HydroCal Inc.

  • Power plant converts gray water into boiler feedwater using hero technology

    The Facility The Bajio Power Project is a 600 MW combined cycle project owned by the Energía Azteca, a Mexican project company jointly owned by InterGen and American Electric Power. The build, own and operate facility is in commercial operation near the municipality of San Luis de la Paz in the state of Guanajuato, approximately 160 miles from Mexico City. In 1999, ...

  • Industrial Laundries Wastewater Treatment Saved $80K per year

    Industrial Waste Water Treatment Success Stories Industrial Laundries Wastewater Treatment - Saved $80K per year ...


    By Integrated Engineers Inc.

  • CETCO scores a perfect 10 with RM-10 - eliminating hazardous waste disposal

    CETCO Oilfield Services’ Industrial Wastewater Treatment Division has over 30 years experience in treating industrial wastewater, helping clients meet compliance requirements and reduce costs. Additionally, CETCO Oilfield Services’ RM-10® flocculant has been successfully applied in the aerospace sector, turning a previously hazardous waste product into a delisted sludge. The aerospace facility ...


    By CETCO Energy Services

  • Chemical recovery - Rare Earth Metals Recovery Company - case study

    Application Rare Earth Metals Recovery Company, which is located in Albany, Oregon, recovers rare earth metals (zirconium, hafnium and titanium) via various proprietary chemical processes. Wastewater Description The wastewater consists of methyl-isobutyl-ketone (MIBK) Waste Disposal Goals The company’s waste disposal goal was ...


  • Is Hexavalent Chromium (Hex Chrome; Chrome VI) a carcinogen?

    In 1990, the International Agency for Research on Cancer (IARC), an agency of the World Health Organization (WHO), published their findings on chromium and chromium compounds as carcinogens.  Chromium may be isolated in any of three volume states: Chrome 0 or metallic chromium; Chrome III called “Chrome 3” or Chrome VI called “Chrome 6,” also called hexavalent ...


    By Atlantic Environmental, Inc.

  • An Overview of Corrugator Paper Pulp Wastewater Treatment

    Wastewater Treatment Success Stories Class 'A' Wasterwater Treatment Facility Printing Facility - 40% Cost Reduction Zero ...


    By Integrated Engineers Inc.

  • Metals & Finishing Industrial Wastewater Treatment

    Industrial Wastewater Treatment Success Stories Metals and Finishing Industrial Wastewater Treatment Aircraft Components - 80% Cost Reduction ...


    By Integrated Engineers Inc.

  • Corrugator Wastewater Reuse Results Containerboard Packaging

    Corrugator Wastewater Treatment Success Corrugator Wastewater Reuse The previous wastewater treatment was composed of the following chemicals: an acidic coagulant, caustic for pH adjustment, and ...


    By Integrated Engineers Inc.

  • Glass Manufacturing Industry - Pollution Prevention Guidelines

    Introduction Pollution Prevention Guidelines to provide technical advice and guidance to staff and consultants involved in pollution-related projects. The guidelines represent state-of-the-art thinking on how to reduce pollution emissions from the production process. In many cases, the guidelines provide numerical targets for reducing pollution, as well as maximum ...


    By The World Bank

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you