fine bubble diffuser Articles

  • Benefits of Venturi Injection Versus Diffuser

    Over the last twenty years I have witnessed Ozone laundry companies come and go. I have witnessed outlandish claims from some of these companies, and quite frankly am tired of listening to the outright lies and fallacies that some of these companies are stating. I would like to look at some of the facts and hope to help our readers make an educated decision about ozone laundry. This month, ...


    By Absolute Systems Inc.

  • Assessment of diffuser pressure loss on WWTPs in Baden-Württemberg

    Aeration of activated sludge is a critical treatment step for the operation of activated sludge plants. To achieve a cost effective treatment process, assessing and benchmarking of aeration system performance are important measures. A simple means of gauging the relative condition of a fine bubble diffused aeration system is to evaluate the pressure loss of the diffusers as oxygen transfer tests ...


    By IWA Publishing

  • Full scale evaluation of diffuser ageing with clean water oxygen transfer tests

    Aeration is a crucial part of the biological wastewater treatment in activated sludge systems and the main energy user of WWTPs. Approximately 50 to 60% of the total energy consumption of a WWTP can be attributed to the aeration system. The performance of the aeration system, and in the case of fine bubble diffused aeration the diffuser performance, has a significant impact on the overall plant ...


    By IWA Publishing

  • Activated Sludge Diffusion Provides Cost Effective Biological Odor Control at Two Texas Wastewater Treatment Facilities

    ABSTRACTDuring recent expansions of the Rowlett Creek Regional WWTP in Plano, Texas and the Wilson Creek Regional WWTP in Lucas, Texas, activated sludge diffusion (ASD) biological odor control systems were installed to treat hydrogen sulfide (H2S) and other gaseous compounds. The ASD systems treat foul air collected from various sources, including headworks and primary distribution structures, ...

  • Prairie farm rehabilitation administration paper

    The aeration efficiency of two types of aeration devices, air injection and mechanical surface aerators was evaluated in farm dugouts in the Peace River Region of Alberta. The air injection systems were tested using three types of diffusers; open-ended tubing, linear fine bubble diffusers and a membrane diffuser. Our results indicate that without aeration, anoxia can develop in the bottom of ...


    By EP Aeration

  • Improving Efficiency and Reducing Energy and Maintenance Costs in Aeration Systems

    Energy costs for operating an aeration system in a biological wastewater treatment plant often times exceeds 75% of the total energy costs for the plant. Adding in blower and diffuser maintenance costs, Aeration Systems are easily the most costly portion of the treatment process, many times consuming so many resources that other parts of the plant may not be properly maintained or operated. By ...

  • Use of Mass Balances for the Determination of Oxygen Contribution of the Different Air Sources in a Full-Scale Membrane Bioreactor

    MBRs necessitate two sources of aeration: one for scouring the membranes (coarse bubble, CB) and the other for the biomass requirements (usually fine bubble, FB). In the framework of a in-depth study of a full scale municipal MBR plant (10 000 p.e.) where CB and FB are in the same tank (Biosep®), mass balances were used to determine the OTR of the different combinations of CB+FB at different air ...

  • Alpha Factors in Full-Scale Wastewater Aeration Systems

    ABSTRACTSurface active agents depress gas transfer at gas-liquid interfaces. They are present as measurable trace contaminants at all environmental and at most industrial gas-liquid interfaces. This paper presents the results of several studies, including lab and full scale studies that show the depression of gas transfer, usually quantified by the alpha factor, can be related to the Reynolds ...

  • An assessment of oxygen transfer efficiency in a gas permeable hollow fibre membrane biological reactor

    The clean water oxygen transfer efficiency (OTE) of a full scale non-porous hollow fibre gas permeable (GP) membrane (surface area of 500 m2) was evaluated at inlet air pressures of 1.2, 1.4, and 1.8 atm using two established testing methods. To form a basis of comparison with traditional aeration technologies, additional testing was done with conventional aerators (fine bubble and coarse bubble ...


    By IWA Publishing

  • In Situ Local Parameter Measurements for CFD Modeling to Optimize Aeration

    ABSTRACTMeasurement methods to determine in situ local parameters were developed, in order to optimize design and operating parameters impacting oxygen transfer in aeration tanks equipped with EDPM membrane diffusers and slow speed mixers. New tools to measure bubble sizes and gas hold-ups were coupled with the traditional ones used to determine liquid velocities and oxygen transfer coefficients. ...

  • Monitoring the variations of the oxygen transfer rate in a full scale membrane bioreactor using daily mass balances

    Oxygen transfer in biological wastewater treatment processes with high sludge concentration, such as membrane bioreactor (MBR), is an important issue. The variation of α-factor versus mixed liquor suspended solids (MLSS) concentration was investigated in a full scale MBR plant under process conditions, using mass balances. Exhaustive data from the Supervisory Control And Data Acquisition (SCADA) ...


    By IWA Publishing

  • Innovative system reduces ammonia at Hawick Sewage Treatment Works

    Hawick Treatment Works has reduced its ammonia discharge thanks to an innovative aeration system installed by market leaders Suprafilt. Aeration experts Suprafilt designed a highly efficient system using MF1100 plate diffusers, which increased the amount of oxygen to the site providing an instantaneous reduction in ammonia levels. The company, who are market leaders in designing and ...


    By Water Active Ltd

  • Energy-efficient wastewater treatment via the air-based, hybrid membrane biofilm reactor (hybrid MfBR)

    We used modeling to predict the energy and cost savings associated with the air-based, hybrid membrane-biofilm reactor (hybrid MfBR). This process is obtained by replacing fine-bubble diffusers in conventional activated sludge with air-supplying, hollow-fiber membrane modules. Evaluated processes included removal of chemical oxygen demand (COD), combined COD and total nitrogen (TN) removal, and ...


    By IWA Publishing

  • A realistic dynamic blower energy consumption model for wastewater applications

    At wastewater treatment plants (WWTPs) aeration is the largest energy consumer. This high energy consumption requires an accurate assessment in view of plant optimization. Despite the ever increasing detail in process models, models for energy production still lack detail to enable a global optimization of WWTPs. A new dynamic model for a more accurate prediction of aeration energy costs in ...


    By IWA Publishing

  • Kärkölä municipality - rationalisation of Waste water plant

    Situation in the beginning two Brush aerators  capacity is not sufficient during  the peaks Brush aerators demand relatively lot maintenance and are in the end of their working life The flow is not sufficient  part of the sludge lands on the bottom of ring basin Direct feedback connection from the oxygen sensor to the aerator via AC Drive is not ...


    By W-Rix Ltd

  • Oxygen, the fix for pond problems

    Aeration of a water feature should have three main considerations. These include preventing thermal stratification, balancing the dissolved oxygen levels throughout the water column from the sludge or benthic layer to the surface and balancing temperature levels throughout the water column. Although oxygen transfer from certain methods may be significant, the greatest amount of oxygenation takes ...


    By EP Aeration

  • Modelling a full scale membrane bioreactor using Activated Sludge Model No.1: challenges and solutions

    A full-scale membrane bioreactor (1,600 m3 d−1) was monitored for modelling purposes during the summer of 2006. A complete calibration of the ASM1 model is presented, in which the key points were the wastewater characterisation, the oxygen transfer and the biomass kinetics. Total BOD tests were not able to correctly estimate the biodegradable fraction of the wastewater. Therefore the wastewater ...


    By IWA Publishing

  • STP Plant Supplier in Chennai – sewage treatment Plant in Chennai Tamilnadu

    RRR ENVIRO SYSTEMS STP plant supplier in Chennai Tamilnadu .We are the Manufacturing and supply of all the types of STP Plant like ASP & FBBR Methods in 10 KLD STP,50 KLD STP, 100 KLD STP, 150 KLD STP, 200 KLD STP, 300 KLD STP, 400 KLD STP, 500 KLD STP, 600 KLD STP with the best rates available in the Indian Market. Process Of STP plant The sewage shall be passed through the screen chamber to ...


    By RRR ENVIRO SYSTEMS

  • Newport News, VA case study

    The Challenge - Retrofit The James River Treatment Plant (JRTP) is one of nine major treatment plants operated by the Hampton Roads Sanitation District (HRSD) in southeast Virginia. The JRTP discharges into the James River, a major tributary to the lower Chesapeake Bay. To meet the goals of the James River Waste Load Allocation, the Virginia Department of Environmental Quality issued HRSD a ...

  • The principles of aeration and mixing utilizing process aerator technology

    Aeration and mixing are necessary elements for aerobic biological wastewater treatment processes to maintain a healthy, stabilized biological population and thus, insure optimal treatment of the wastewater assuming there is adequate contact time and substrate available. In the design of wastewater treatment plants, aeration typically involves supply of both oxygen and mixing. Aeration is a large ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you