flame ionization monitoring Articles

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • Avoiding Sewer Fires with Vapor Space Organics Monitoring

    ABSTRACTRegulation of flammable gases released from wastewater discharges is facilitated by the use of the Vapor Space Organics test method. Such regulation can reduce the risk of a flash sewer fire, resulting damage and potential injury. The updated 2003 VSO process developed by Severn Trent Laboratories produced data that was equivalent to the 1990 VSO process developed and used by the ...

  • Monitor Sulfur Compounds in Petroleum Chemical, Environmental, and Other Samples, Using a Special-Purpose Capillary GC Column

    Measurement of sulfur compounds is important to petroleum chemical analysts for several reasons, including a need to monitor odor problems and prevent catalyst poisoning.  Quantification of sulfur compounds is also important to environment analysts and to food, beverage and fragrance analysts for similar reasons.  Analyses of sulfur compounds can be complicated by the inability to ...


    By MilliporeSigma

  • Case study N°AA7 – Ambiant air monitoring – VOC Purge & trap

    Context & Challenges Volatile organic compounds (VOC) can be dissolved in water. Sometimes water is polluted and to study contamination of VOC in finished drinking water, VOC must be measured. Chromatotec Solutions Chromatotec has developed a specific system for the measurement of VOC in water: a Purge & Trap system, the airmoPURGE. The ...


    By Chromatotec Group

  • Real Time TOC Analysis in Steam and Condensate

    Executive Summary Steam in petro/chemical plants could be contaminated with hydrocarbons (TOC = Total Organic Carbons) from various sources. In any case this is a sign for defects in the process, whether it they occur in the heat exchanger, the blow down vessel, the condensate recovery or other parts of the system. Conventional solutions to monitor such contaminations use TOC- ...


    By JCT Analysentechnik GmbH

  • The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe

    POLLUTION S.r.l. manufactures POLARIS FID analyser, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...


    By Pollution Srl

  • airmoTWA: New Expert System for GC-FID/MS

    Chromatotec has developed the first TRAP-GC-FID/MS designed for continuous monitoring of Volatile Organic Compounds (VOCs), inorganic molecules and permanent gases. In addition to the mass spectrometer (MS), this system encompasses the same trap, thermo desorption and separation technologies as airmoVOC analyzers (current mCERTS approved GCs analyzers). For VOCs analysis, the Flame Ionization ...


    By Chromatotec Group

  • Air emissions from the automobile manufacturing industry a bio-oxidation pilot study of paint emissions control

    Bio•Reaction Industries (BRI) was contacted by Toyota to assess the abatement potential of an engineered bio-oxidation system (biofilter). The proposed intent of the pilot was to evaluate the effectiveness of biofiltration as available alternative to traditional VOC removal technology on an existing 3 stage wheel paint booth. A pilot unit consisting of a biotrickling filter and a separate ...


  • Air Emissions from the automobile manufacturing industry: a bio-oxidation pilot study of paint emissions control

    Bio•Reaction Industries (BRI) was contacted by Toyota to assess the abatement potential of an engineered bio-oxidation system (biofilter). The proposed intent of the pilot was to evaluate the effectiveness of biofiltration as available alternative to traditional VOC removal technology on an existing 3 stage wheel paint booth. A pilot unit consisting of a biotrickling filter and a separate ...


  • TVOC measurement for LEED/green building evaluation

    Total Volatile Organic Compounds (TVOC) may be evaluated when building designers/managers are pursuing the Leadership in Energy and Environmental Design Green Building Rating System for New Construction (LEED-NC) EQ Credit 3.2. The latest LEED-NC guidance document specifies that the maximum allowed concentration of TVOC measured in a building (post construction, pre-occupancy) is 500 µg/m3; the ...


  • Industrial applications – Air analysis in clean air room - Case study

    Context & Challenges To ensure people’s safety and a good repeatability of industrial process, the analysis of ambient air is crucial. Especially, electronic boards are produced in clean air room by complex lithographic process using very reactive chemicals. The nature and concentration of volatile compounds can be different depending on the chemical process and can also vary ...


    By Chromatotec Group

  • Triad expedites brownfields redevelopment in Fairbanks

    The Fairbanks North Star Borough (FNSB) used Triad in 2006-2007 to assess environmental conditions at a municipal property along the Chena River in Fairbanks, AK. FNSB accelerated the site investigation as part of a brownfields assessment grant received from the U.S. EPA in 2005. Low-level contamination had been identified onsite in past investigations, but its extent and impact on future ...

  • Full-scale SVE system operates in tandem with groundwater treatment

    Since 1993, SVE has been implemented using two designs at the TP Industrial, Inc. (TPI) site in Gardena, CA, to treat soil contaminated with chlorinated solvents. The SVE system was modified in 1997 to improve emissions control efficiency by using carbon adsorption units that treat effluent from an air-stripping system for treating site ground water. By the end of 2007, SVE had removed a ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you