ftir testing Articles

  • FTIR gas monitor for diverse applications

    QUANTITECH, a leading supplier of environmental monitoring instrumentation, has recently supplied EURO Environmental Services in Ireland with a transportable Gasmet FTIR multiparameter gas analyser which EURO Environmental's Managing Director Geoff Fitzpatrick says, “is proving invaluable in many varied applications across a broad selection of industries.” With headquarters in Drogheda in Ireland ...


    By Quantitech Ltd

  • FTIR gas analysis improves container safety

    Introduction Entry to freight containers represents a significant hazard to staff responsible for inspection, stuffing or destuffing because of the large number of airborne chemicals that can be present. Research in Germany and the Netherlands found hazardous levels of gases and vapours in around 20% of all containers and this level of contamination is now accepted as commonplace. It ...


    By Gasmet Technologies Oy

  • FTIR spectroscopy as a novel approach towards providing effect‐based endpoints in duckweed toxicity testing

    Traditional duckweed toxicity tests only measure plant growth inhibition as an endpoint, with limited effects‐based data. This study aimed to investigate whether Fourier‐transform infrared (FTIR) spectroscopy could enhance the duckweed (Lemna minor L.) toxicity test. Four chemicals (Cu, Cd, atrazine, and acetochlor) and four metals‐containing industrial wastewater samples were tested. After ...


    By John Wiley & Sons, Ltd.

  • FTIR gas analyzers support management of fire at UK waste facility

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents.  Arrangements have been made in England to bring together experts from the Environment ...


    By Gasmet Technologies Oy

  • Comparing TGA, FTIR and fixed filter infrared analyzers for measuring soot levels in in-service lubricants

    Measuring soot in diesel engine oil has become more important as soot levels get higher due to exhaust gas recirculation. As soot isone of the key indicators for the condition of the oil, diesel engine maintenance programs performing regular soot checks can realize cost savings by extending drain periods and reducing used oil disposal. TGA (Thermal Gravimetric Analysis) is the traditional method ...


    By Spectro Scientific

  • Emission Testing and Monitoring

    Presented in Track B4: EMISSION TESTING & MONITORING at EUEC 2011, January 31 Phoenix, Arizona B4.1  | Update on PM2.5 and Condensable Particulate Matter Emissions Measurement Methods Larry Hottenstein |  Partner, Environmental Resources Management Following the promulgation of the PM2.5 ...

  • Materials Testing Laboratory Provides Cutting Edge Contamination Testing Solutions

    Many industries have extremely tight parameters for any contamination of parts that are used in their manufacturing process.  Testing for contamination and quality control is an integral part of these companies’ final products. At EMSL Analytical, the Materials Testing Laboratory has extensive experience in providing highly detailed analytical services to assist manufacturers in ...


    By EMSL Analytical, Inc.

  • Detection and measurement of toxic gases from destructive testing of batteries

    Problem Statement New formulations of organic-compound-based batteries for vehicle use must be tested for release of potentially harmful and toxic gases if crushed in accidents. Potential gases include hydrocarbons, fluorocarbons, and hydrogen fluoride, released within seconds of an incident. Actual time-resolved and quantitative data are required from destructive testing to ascertain ...


    By CIC Photonics, Inc.

  • Mobile Stationary Source Emissions Testing, Coming to a Facility Near You?

    Last week, Antea Group had the unique opportunity to perform a RATA (relative accuracy test audit) of the emissions from a thermal oxidizer at an ethanol production facility located in Minnesota using a state-of-the-art mobile testing laboratory. During this RATA audit, actual stack emissions levels (including NOx, SOx, CO2, CO, O2, flow rate, temperature, velocity and pressure) from the ...


    By Antea Group - USA

  • New ASTM Test Method Offers Quick and Easy Oil and Grease Measurement for Water and Soil Samples

    Onsite Field Measurement of Oil and Grease A quick and easy field analysis method for determining oil and grease concentration levels is important for both offshore oil platforms and soil remediation sites.. Prior to the Montreal Protocol, infrared (IR) analysis using Freon as an extraction solvent was a widely used field and laboratory method. In 1999, the U.S. EPA promulgated Method 1664A ...


    By Spectro Scientific

  • Portable IR Analyzer Provides ASTM Field Test Method for Measuring Soot Levels In Diesel Engine Lubricating Oils

    The InfraCal Soot Meter, from Wilks Enterprise, gives users an approved ASTM testing method for measuring the percent level of soot in diesel engine lubricating oils -- ASTM Method D7686-2011 entitled “Test Method for Field-Based Condition Monitoring of Soot in In-Service Lubricants Using a Fixed-Filter Infrared (IR) instrument.” While there is widespread disagreement on used-diesel ...


    By Spectro Scientific

  • Effects of pH on chromate(VI) adsorption by Spirulina platensis biomass: batch tests and FT-IR studies

    Raw and methylated biomass of Spirulina platensis was employed in chromate batch adsorption tests at pH range 1–7. The acid conditions seemed to favour the removal of chromium (Cr) with a yield of 87.0 and 97.6% by using raw and methylated biomass, respectively. However, the chromate and total chromium determination, carried out in the same sample, evidenced that a fraction of ...


    By IWA Publishing

  • Characterisation of a bioassay using the marine alga Dunaliella tertiolecta associated with spectroscopic (visible and infrared) detection

    This paper describes an ecotoxicological test using the alga Dunaliella tertiolecta associated with visible (VIS) and infrared (FTIR) spectroscopic detection. The estimation of toxicity is performed by measuring the cell density at 432 nm instead of 665 nm the results are comparable with those obtained by conventional visual or automatic estimation of celle density. FTIR spectroscopy gives an ...


    By Inderscience Publishers

  • Comparative in situ PET biodegradation assay using indigenously developed consortia

    A soil burial test was carried out to evaluate the biodegradation of polyethylene terephthalate under natural environment for a period of six months in presence of three different indigenously developed bacterial consortia. These consortia comprised of potential polymer-degrading bacterial cultures isolated from various waste disposal sites. The comparative biodegradation of PET samples in ...


    By Inderscience Publishers

  • The Gasmet story from an academic idea to a global business

    In this article, Dr Petri Jaakkola, founder and Chairman of Gasmet Technologies Oy explains how an idea shared by a group of researchers at the University of Oulu in Finland, during the early 1970s, developed into one of the world’s leading gas monitoring instrumentation manufacturers. Early history – technology development At first, the Finnish researchers understood ...


    By Gasmet Technologies Oy

  • Removal of heavy metals from aqueous solution by limestone

    This study focused on the removal of Pb(II), Cd(II), Cu(II), and Zn(II) using reagent solutions by natural limestone in a batch system. The sorbent, collected from the Late Cretaceous limestone beds, Tunisia, was characterised by X–ray diffraction (XRD), chemical analysis (XRF) and infrared spectroscopy (FTIR). XRF showed that the studied limestone contained high amount of calcium carbonates. XRD ...


    By Inderscience Publishers

  • Flocculation properties of bioflocculant MBF-7 produced by Penicillium purpurogenum in kaolin suspension

    The properties and modes of flocculation for kaolin suspension with bioflocculant MBF-7 produced by Penicillium purpurogenum, were investigated. The results showed that the optimum pH and dosage for flocculation was above 8 and more than 40 mg L−1, respectively. Flocculating activity of MBF-7 was increased in the presence of Mg2+, Ca2+, Al3+, or Fe3+, especially in the presence of Ca2+, while ...


    By Inderscience Publishers

  • Continuous Emissions Monitoring Equipment – Guidance & Selection

    There has never been such a wide range of analysers and systems available for continuous emissions monitoring as there is today. In the UK there are over 12 manufacturers and distributors offering CEMS (continuous emissions monitoring systems) using a variety of technologies including UV and IR absorption, FTIR, DOAS, chemiluminescence and photoacoustic spectroscopy (PAS). The majority of CEMS ...

  • Identification of forensic fabrics using a portable Raman spectrometer

    At a crime scene, a police officer collects a fiber sample that may prove to be invaluable evidence in identifying a criminal or exonerating an innocent person. While FTIR has been used for analysis in the past, the strong absorption of the fabric or the glass slide where it is mounted makes the spectrum very hard to interpret. In recent years, Raman spectroscopy has been studied extensively for ...


    By B&W Tek

  • Monitoring greenhouse gases from biofuel crops

    Global issues such as climate change and energy security have driven rapid growth in renewable energy production - wind, solar, tidal, geothermal, hydro, biofuels etc. However, logically, each of these methods should deliver a net benefit in terms of greenhouse gas (GHG) reduction, so researchers in the United States have employed portable FTIR analysers to study the GHG emissions of biomass ...


    By Gasmet Technologies Oy

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you