gas feed chlorinator Articles

  • Controlling the addition of Chlorine into a Process

    There are several methods for controlling the addition of chlorine into a process. These methods include flow proportional injection, ORP (oxidation reduction potential) or a residual chlorine analyzer. Each method measures a different process characteristic. Depending on the specific type of process being controlled, there generally is a best choice for controlling the injection of either ...


    By Walchem, Iwaki America Inc.

  • From Gas to Liquid: Large-Scale Chlorination System Conversion

    Abstract A number of wastewater treatment facilities using gas disinfection have decided to convert to liquid disinfection for several reasons including safety, regulatory, security, and economic factors. An optimal technology plan should be developed to facilitate the conversion. This presentation provides a case study of a large chlorine disinfection system, and demonstrates key issues of ...

  • Comparing the Realities of Elemental Chlorine vs. Sodium Hypochlorite

    Recently, we have seen a growing trend towards the use of a less reliable and more costly disinfection chemical, Sodium Hypochlorite. Much of this can be attributed to the fact that large companies making chemical metering pumps for other uses or other alternative disinfection devices as well as chemical suppliers who profit more by selling costly Sodium Hypochlorite have proliferated misleading ...


  • One of the largest ipp power plants in the middle east uses membrane desalination for boiler feed water

    The Facility Sidi Krir Unit 3 & 4 Power Plant, developed by InterGen and Edison SpA, is located about 30 kilometers west of Alexandria, Egypt. It is a natural gas fired power plant and at 685 MW generating capacity, is the largest IPP thermal power plant in the Middle East. The plant consists of two power blocks, which share a common membrane based Seawater Desalination system ...

  • Gas Detection in Public Swimming Pool Facilities

    Recreational facilities’ indoor swimming pools provide a venue for exercise, competition and fun for all ages as patrons splash, swim, dive and float around in the crystal clear water. To keep the water fit to swim in requires a disinfectant maintenance program commonly using Chlorine, or Chlorine and Ozone. Chlorine is a powerful, corrosive disinfectant and in both gas and liquid forms it ...

  • Analytik Jena AG: State of the Art - Fully Automated and Matrix-Optimized Gas Analysis with multi EA 5000

    The analysis of gaseous matrices is still a real challenge. No matrix type is as versatile in its behavior and the requirements for sample feed and combustion process. This makes it difficult to gain quick, precise, and reliable results. Thanks to the outstanding flexibility of the application-optimized gas sampling systems, the elemental analyzer multi EA 5000 can analyze liquefied gases (LPG), ...


    By Analytik Jena AG

  • Converting a Major Water Treatment Plant: Westfall Mixer Answers the Needs

    The Challenge: Plant Conversion While Maintaining Water QualityThe Portland Water District needed to convert a major chlorine gas feed system to liquid sodium hypochlorite in order to eliminate hazards associated with gas systems and to enhance chlorine residual throughout the distribution system. Wright-Pierce was selected to engineer the project. The largest water treatment facility in ...

  • West Columbia, SC, municipal drinking water

    The Lake Murray Water Treatment Plant (LMWTP) in West Columbia, S.C., was dedicated in 1991 with a capacity of 6 million gal per day (mgd). With upgrades completed in 2007, the plant has a current capacity of 22.5 mgd. Most of the water from LMWTP is sold; 19% of the water is distributed to the system for which the LMWTP management and staff is responsible. 0In the early 1990s, the water ...


    By MIOX Corporation

  • Mixed Oxidants show disinfection benefits for municipalities

    “The most significant advantage over gas chlorination or hypochlorination is an ability to maintain chlorine residuals further along the water distribution system, due to better biofilm removal. Other noted advantages of mixed oxidants are ease of operation with self-cleaning electrolytic cell on-site generators, fewer safety issues in comparison to gas chlorination, and lower costs ...


    By MIOX Corporation

  • Grundfos reference – disinfection case study

    First SELCOPERM unit installed within the Czech Republic to serve for potable water disinfection through the electrical chlorination method ŽLUTICE, Czech Republic: 1/3 of the total capacity of the waterworks at Žlutice has been designed for supplying drinking water to a group of communities found within the catchment area of Žlutice (approximate population of 14,000), the remaining 2/3 ...


  • ClorTec™ On-site Disinfection Helps Ensure Safety at British Columbia Water Treatment Facility

    Constructed in 1997, the District of Chetwynd Water Treatment Plant (British Columbia, Canada) treats nearly 2,500 cubic meters of water per day using gas chlorination as its primary form of drinking water disinfection. With recent concerns about the safety of chlorine gas, including potential eye, skin and respiratory irritation and the risk of death with high exposure, the district elected ...


    By De Nora Water Technologies

  • Case study - Mobile remediation system

    OVERVIEW A large consulting and contracting firm owns and operates several ex-situ Thermal Desorption Units (TDUs). Each single-load Thermal Desorption Unit has the capacity of desorbing 15 tons of soil per hour at a temperature of 400°F - 900°F. These Thermal Desorber Units have been designed to operate on both chlorinated and non-chlorinated RCRA, CERCLA, and private industry ...

  • Performance of a conventional surface water plant using mixed-oxidants for microflocculation and final disinfection

    The City of Santa Fe, NM utilizes both surface water and well water to achieve a system-wide peak production of 22 million gallons per day (MGD). In March 1998, the city incorporated MIOX mixedoxidant disinfection technology for pre-treatment and final disinfection of the water treated in an 8 MGD surface water plant. Concurrently, a filter backwash recycling system was installed as well as ...


    By MIOX Corporation

  • Preliminary Report on CANSOLV® System Commercial Experience

    Three reference plants utilizing the CANSOLV® System aqueous diamine based regenerable SO2 scrubbing technology are now operating in regular commercial production. A unit in Europe is treating the tailgas from an incinerator burning a ...

  • Dressing down groundwater contamination

    Unlike the late Paul Newman, who bottled his special-recipe salad dressing and sold it in supermarkets, Dr. Robert Borden simply mixes up his own 'dressing' and pumps it into the ground. That’s because the environmental engineering professor and his graduate students are more interested in feeding microbes to clean up contaminated groundwater than in making just another Ranch dressing. “It’s ...


    By EOS Remediation, LLC

  • City of Roswell, Georgia - Case Study

    In late 2011, the United States Army Corps of Engineers (USACE) approved plans to install a new well and build a new water treatment facility for the City of Roswell, Georgia. Barlovento LLC was selected during a competitive bidding process to provide an iron and manganese removal system for the new water supply. AdEdge Water Technologies, LLC was contracted to design, manufacture, and commission ...

  • Cost effective boiler makeup system using membrane desalination for power plant in dominican republic

    The Facility Andres Power Plant, developed by Caribbean Thermal Electric LLC, is located in Boca Chica, near Santo Domingo, Dominican Republic. It is a 300 MW gas fired combined cycle power plant and is one of the largest IPP power plants in the Dominican Republic and will supply electricity to Corporacion Dominicana de Electricidad. The plant consists of two power blocks, which ...

  • Chloramines

    OVERVIEW When chlorine is added to a water supply containing certain organics, the formation of halogenated organics occurs. Called 'trihalogenated methanes' (THM's) these reaction products are suspected carcinogens and maximum allowable limits in municipal supplies are imposed by the U.S. Environmental Protection Agency (EPA). To reduce the potential for the formation of THM's, many U.S. ...

  • Northern Indiana Power, NIPSCO cooling tower

    A new onsite mixed oxidant system at the R.M. Schahfer Generating Station of Northern Indiana Public Service Co. (NIPSCO) in Wheatfield, IN, has yielded substantial treatment chemical cost savings and improved summer operation compared to the control unit cooling tower. NIPSCO, an electric and gas utility and subsidiary of NiSource Inc., was approached about the system during a biannual ...


    By MIOX Corporation

  • Technology Spotlight: BIONOxSOLVER NOx: An Eco-Friendly Scubbing Solution

    NOx scrubber installations employing Bionomic Industries' BIONOxSOLVER have proven to be simpler, safer and considerably more cost effective than systems using sodium sulfide or hydrosulfide scrubbing reagents. Sodium sulfide and hydrosulfide are DOT libeled hazardous compounds that require dealing with major worker safety issues. They are extremely corrosive, causing difficulties in safe ...


    By Bionomic Industries Inc.