gas filter correlation Articles

  • Gas analysers support management of Swindon fire

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents. Arrangements have been made in England to bring together experts from the Environment Agency ...


    By Quantitech Ltd

  • Comparing TGA, FTIR and fixed filter infrared analyzers for measuring soot levels in in-service lubricants

    Measuring soot in diesel engine oil has become more important as soot levels get higher due to exhaust gas recirculation. As soot isone of the key indicators for the condition of the oil, diesel engine maintenance programs performing regular soot checks can realize cost savings by extending drain periods and reducing used oil disposal. TGA (Thermal Gravimetric Analysis) is the traditional method ...


    By Spectro Scientific

  • Laboratory, pilot and industrial-scale validation of numerically optimized reverse-flow gas cyclones

    This paper addresses the experimental validation of the optimum design of reverse-flow gas-cyclones, obtained through the solution of a numerical non-linear optimization problem, viz. maximizing cyclone collection. The simulation model is based on the predictive properties of a finite diffusivity model, where the particles' turbulent dispersion coefficient is estimated through an empirical ...

  • Is H2S a suitable process indicator for odour abatement performance of sewer odours?

    Odour abatement units are typically designed and maintained on H2S concentrations, but operational failures are reported in terms of overall odour removal, suggesting a wide range of malodorous compounds emitted from sewers that may not be efficiently removed by existing odour abatement processes. Towards providing greater insight into this issue, several activated carbon filters and biofilters ...


    By IWA Publishing

  • Low-mass PM analyzer MEXA-1370PM — Improvement of the Performance for PM Composition Analysis —

    Particulate matter (PM) emitted from engines is currently measured by the filter weight method. The filter weight method passes diluted emission gases through a filter collecting the PM, and post test weighs the mass of the collected PM on a precision balance. However, this method is time consuming, and with decreasing PM emission volumes, improvements in accuracy were needed. So the MEXA-1370PM ...


    By HORIBA Europe GmbH

  • Biotreatment of Odors from the Zimpro Sludge Conditioning Process

    Management of odor emissions generated during thermal sludge conditioning is a well known disadvantage of the “Zimpro” process. Traditional methods of using chemical oxidation and high temperature destruction result in the formation of secondary products, such as chlorine gas, organic halocarbons or nitrogen oxides. In this study, biotrickling filter technology was evaluated at the Villa Hills ...


    By PRD Tech, Inc.

  • Observation based analysis for the determination of equilibrium time constant between ammonia, acid gases, and fine particles

    Experimental measurements of ammonia, acid gases, and the inorganic components of atmospheric aerosols were made at a commercial hog farm in eastern North Carolina from May 1998 to June 1999 by an annular denuder system (ADS). The ADS consisted of a cyclone separator, one diffusion denuder coated with sodium carbonate, another diffusion denuder with citric acid, and a filter pack containing ...


    By Inderscience Publishers

  • Case study - GRO in soil at gasoline UST site

    These case studies show the performance using Sitelab’s UVF-3100 analyzer testing gasoline range organic hydrocarbons.  This includes benzene, xylene, BTEX and other volatile petroleum compounds in the GRO or VPH C6 to C10 hydrocarbon range. When calibrated using Sitelab's GRO calibration kit (CAL-025), the UVF analyzer produces test results that correlate well to laboratory ...


    By Sitelab Corporation

  • Case study - Performance testing PAHs in soil

    These case studies highlight Sitelab’s accuracy from customers who have used the UVF-3100D for testing Target PAHs. This test correlates well to U.S. EPA Method 8270 or similar GC methods, which includes a list of 16 or more compounds. The analyzer is fitted with special optical filters sensitive to this same group of hydrocarbons. Examples of UVF-3100D testing Polycyclic Aromatic ...


    By Sitelab Corporation

  • Upstream Particulate Removal for Rtos on Direct-Fired Osb Dryers – How much is enough?

    Abstract Since 1994 Regenerative Thermal Oxidizers (RTOs) have been applied to direct wood-fired OSB dryers for the purpose of VOC abatement. In early direct wood-fired OSB dryer applications many OSB producers felt that upstream particulate control was not necessary. However, the ash from the combustion of wood waste created a host of new operational problems for the RTO systems. This paper ...

  • Method 301 Evaluation of Candidate conditional methods case study

    A new metal emissions measurement and validation system has recently been developed that has the potential to significantly improve our understanding of metal emissions from a wide range of source categories. This system consists of: A continuous emission monitoring system (Xact-CEMS) An instrumental analyzer procedure (Xact-IAP) A sampling and analysis measurement method ...


    By Cooper Environmental

  • Field Detection of Chlorinated Alkenes in Well Water using the FROG-4000 Portable GC - Case Study

    Introduction Defiant’s FROG 4000, a portable GCPID system, was used to identify and determine the concentration of chlorinated alkenes in several extraction wells located in Tacoma Washington. Split samples were taken at each well and sent to an offsite lab for analysis. This case study examines the field exercise and highlights the high degree of agreement between the offsite lab and ...


    By Northern ANI Solutions Ltd.

  • Pilot-Scale Biofilter Test for Treating Zimpro Odors

    The thermal sludge conditioning process of U.S. Filter/Zimpro Corporation, Rothschild, Wisconsin (Zimpro process) is primarily used to improve dewatering characteristics of the waste sludge. The process entails a partial breakdown through oxidation and hydrolysis of complex, high molecular weight organic compounds, such as, proteins, fibers, carbohydrates, and fats. The partial breakdown of ...


    By PRD Tech, Inc.

  • Continous Emission Monitoring (CEMs)

    Presented in Track B1: CEMs at EUEC 2011,January 31 Phoenix, Arizona   B1.1  | Particulate CEM for wet FGD plant William Averdieck |  Managing ...

  • Smart LDAR — more cost-effective?

    On December 19, 2008, EPA issued a final rule establishing a voluntary Alternative Work Practice (AWP) to detect leaks of volatile organic compounds (VOC) and hazardous air pollutants (HAP) from process equipment (FR Vol. 73, Number 246), thereby providing the regulated community additional flexibility in complying with leak detection and repair (LDAR) requirements. The AWP allows owners or ...


    By Trinity Consultants

  • Treatment plant protected by effluent monitor at major drinks factory

    The installation of a BioTector continuous TOC (Total Organic Carbon) monitor to police the front end of Cobevco’s wastewater treatment plant has enabled tight control of the treatment process. Delivering results 20 times faster than laboratory techniques, the monitor at the Elton facility in Cheshire provides advance notice of organic overload so that the plant is able to instantly divert ...


  • Low-Flow (Minimal Drawdown) Ground-Water Sampling Procedures

    Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water ...


    By Solinst Canada Ltd.

  • Reducing Odor and VOC Emissions

    The Montgomery County Regional Composting Facility (MCRCF) in Silver Spring, Maryland is designed to process 400 wet tons/day of lime amended biosolids from the Blue Plains Wastewater Treatment Plant (WWTP) in Washington, D.C. Recently, political pressures forced operations to cease at the MCRCF. Although the aerated static pile composting plant’s fate has not been completely decided, its owner, ...


    By BioCycle Magazine

  • New laser-based dust emission monitoring system

    Abstract A new generation of continuous particulate matter concentration monitoring instruments is presented, covering a measuring range of 0 to 1000 mg/m3. The laser-based scattered light instrument gives an improved stability as well as excellent resolution in the low range. This enables high concentration measurement as well as especially low emission monitoring down to 0.01 mg/m3 with a ...


    By Sigrist-Photometer AG

  • Peroxygen Mediated Bioremediation of MTBE.

    ABSTRACT: Evidence is mounting, from laboratory and field studies, that oxygen plays a role in the bioremediation of methyl tertiary butyl ether (MTBE). Our experience with a number of commercial applications of peroxygen, in the form of Oxygen Release Compound (ORCâ), correlates the provision of enhanced aerobic conditions with enhanced MTBE biodegradation. Subsequent laboratory and field ...


    By REGENESIS

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you