gas sampling Articles

  • Train derailment prompts contaminated land investigation - Case study

    On March 30th 2015 a long freight train, transporting a variety of goods including lumber and chemicals, wound its way through the state of Mississippi. At around 5pm, part of the train failed to negotiate a curved portion of the track in a rural area near Minter City, resulting in the derailment of nine railcars, one of which leaked chemicals onto agricultural farmland and woodlands. Emergency ...


    By Gasmet Technologies Oy

  • Sampling VOCs with Supel™-Inert Film Gas Sampling Bags

    Sampling VOCs with Supel™-Inert Film Gas Sampling Bags with Thermogreen™ LB-2 Septa as an Alternative to Tedlar® For 10 years, Supelco has provided our customers with high quality Tedlar gas sampling bags. Recently, we expanded our gas sampling bag line to include an alternative to Tedlar for sampling VOCs that incorporates our low-bleed Thermogreen™ LB-2 ...


    By MilliporeSigma

  • Evaluating Leaks in a Soil Gas Sampling Train

    ABSTRACT The current advisory for active soil gas investigations in California requires leak tests to be conducted at eveiy soil gas probe while taking a sample. A leak may allow ambient ak into the sample train thus diluting the soil gas and underestimating the results. Also, the leak check compound itself may have impurities thereby contaminating the sample. The advisoiy suggests leak ...


    By Eurofins Air Toxics Inc

  • Impact of Sampling Media on Soil Gas Measurements

    Abstract To evaluate the vapor intrusion pathway for a building and to assess the associated human health risks, soil gas samples near the building site and under the building foundation may be collected. In order to meet risk assessment goals, the analytical laboratory is often required to report compounds of concern for these soil gas samples down to the part per billion ranges or lower. ...


    By Eurofins Air Toxics Inc

  • Overcoming Natural Gas Sampling Challenges in Oil & Gas Applications

    It is a fact that in order to comply with various government rules and regulations, oil and gas companies have to continually take natural gas samples to prove the gas composition and amount of gas flowing in their oil fields. The challenge comes in trying to actually take an adequate gas sample representative of the gas flow. First, engineers must carefully consider where the ...


    By Sierra Instruments, Inc.

  • Area Monitoring: Diffusion Sampling

    Indoor and outdoor gas hazards that exist in open areas are usually monitored using diffusion-type sensors. A diffusion sensor has no active sample-drawing system; diffusion sensors rely on the ambient air movement and pressure to deliver the sample to the sensing element. Diffusion-type sensors are a reliable and cost-effective way to monitor open area gas hazards. When installing diffusion ...

  • Ambient Air Sampling Methods

    Pollutants are nothing but any substance that may present in an atmosphere in such a concentration that it may harmful to surrounding, living organism or human being. Sampling and analysis of air pollutants is known as Air quality monitoring and it is major part of environmental monitoring. There are many advanced types of ambient air Sampling methods. we will learn here only which are most ...


    By Perfect Pollucon Services

  • Biodegradation Tests for Wastewater Samples

    Biodegradation Tests for Wastewater Samples Biodegradation tests usually involve comparison of the oxygen uptake of a test sample – or gas production for anoxic or anaerobic tests – to that for a readily biodegradable control substrate (usually acetic acid, ethanol, or aniline). While biodegradation characteristics can vary among chemical types and wastewater sources, typical patterns are shown ...


    By Challenge Technology

  • GC/MS analysis of a complex sample in DCM using hydrogen carrier gas

    Labs worldwide have recently found that helium has been in short supply, leaving a number of labs without carrier gas. Added to this, helium prices have doubled over the past 10 years causing a number of labs to look into alternative carrier gases for GC, such as nitrogen and hydrogen. As well as lower price and unlimited availability, hydrogen has a number of potential advantages over helium, ...

  • What is a Sanitary Sample Valve?

    As its name suggests, this type of valve is used in processing industries for sampling various products in different states of matter such as liquid and gas. The different types of fluids are examined using various techniques using sampling valves. Some of the main ...


    By Adamant Valves

  • Air Sampling During NPP Accident

    There has been considerable interest recently generated regarding emergency air sampling protocols as a result of the Fukushima accident in Japan. A major concern involving air sampling requirements is the accurate determination of gaseous-radioactive iodine species emitted from the NPP to the environment as a result of an accident. During normal NPP operation gaseous radioactive iodine ...


    By F&J Specialty Products, Inc.

  • Groundwater: Low-flow Purging and Sampling

    Significant timesavings, improved sample process integrity, quality assurance and minimal quantities of potentially contaminated purge water to manage - are attractive as the focus on groundwater quality sharpens and economics demand best cost-benefit based methods Water has become a vitally important resource.  Maintaining its quality and quantity and avoiding pollution are set to be ...


    By Geotech

  • Soil CO2 Flux Measurements -- Using the LI-8100 System to Collect Air Samples for Estimating Soil Trace Gas Flux

    Air samples can be collected from the same air stream used to measure soil CO2 flux with the LI-8100 Automated Soil CO2 Flux System, for estimating the flux of trace gas, such as methane (CH4), ammonia (NH3), nitrous oxide (N2O), isotopic species, etc. This application note describes a simple method for obtaining air samples from the LI- ...


    By LI-COR

  • Isolate & sample up to 7 zones in one borehole

    CMT Multilevel Systems isolate and monitor up to seven discrete zones in one borehole; monitor 7 zones in the 1.7" (43 mm) System; 3 in the narrow 1.1" (28 mm) System. Both options are low cost. The single tube design makes them fast and easy to drill and install in one day. System flexibility allows port locations and monitoring strategy to be finalized right on site. CMT wells are ideal for ...


    By Solinst Canada Ltd.

  • News on Air 2013, Volume 1: Products for Sampling

    For decades, Sigma-Aldrich has been a key supplier of innovative & high technology air monitoring products for various areas of gas/air sampling. Enclosed, you will find an overview on new and interesting devices to improve or simplify your air sampling. Supelco and Sigma-Aldrich offer a range of active and passive air sampling products, in addition to various analytical chemistry tools ...


    By MilliporeSigma

  • The 10 Key Factors in Selecting a Stack Sampling Firm

    Summary: This document is a summary of the key factors that you should take into consideration when hiring a stack testing firm.This has been prepared in conjunction with the ASTM criteria for standard practice of testing companies.The ASTM criteria has been supplemented, based on 125 years of direct testing experience, which is the combined years of experience of the individuals that contributed ...

  • Analysis of pesticide residues in drinking water samples using solid-phase micro-extraction (SPME) coupled to a gas chromatography-electron-capture detector (GC-ECD)

    The headspace solid-phase micro-extraction (HS-SPME) method with polydimethylsiloxane (PDMS, 100 μm) fiber is a cost-effective technique for the determination of different pesticide residues in environmental and biological samples followed by a gas chromatography-electron-capture detector (GC-ECD). In the present study more than 147 water samples collected in and around Lucknow city were ...


    By IWA Publishing

  • Knotted in-tube and mini-column solid phase extraction of polycyclic aromatic compounds and nitroaromatics from aqueous samples for their determination by gas chromatography–mass spectrometry

    The selectivity of in-tube extraction by PTFE tubing vis-a-vis mini-column SPE has been evaluated for preconcentration and cleanup of PACs in their natural matrix, and has been found to effectively remove many polar analytes such as nitrogen containing aromatic heterocyclic compounds, anilines, phenols and certain organophosphorus pesticides. Knitting of tubings created a secondary flow pattern ...


    By Inderscience Publishers

  • Learn How to Implement a More Effective Emissions Monitoring Strategy with Our Application Note, “The Art of Emissions Monitoring and Sampling: Maintaining Gas Integrity”

    Over the past 15 years, all of us here at E Instruments have used our expertise to design, manufacture, and distribute quality emissions monitoring equipment, air quality monitors, and many other products to clients all over the world. Aside from creating many high-quality and reliable instrumentation solutions, something else we've always ...

  • Manufactured gas plant investigation

    A two-person BEACON field team installed 304 PSG Samplers over a two-day period. Samplers were installed through soils, gravel, asphalt, and concrete. To accommodate field schedules, the Samplers were exposed for eight days in the field and the two-person field team required one day for retrieval of the Samplers. Survey results clearly showed where source areas are present on the site, as well as ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you