gas sampling train Articles

  • Evaluating Leaks in a Soil Gas Sampling Train

    ABSTRACT The current advisory for active soil gas investigations in California requires leak tests to be conducted at eveiy soil gas probe while taking a sample. A leak may allow ambient ak into the sample train thus diluting the soil gas and underestimating the results. Also, the leak check compound itself may have impurities thereby contaminating the sample. The advisoiy suggests leak ...


    By Eurofins Air Toxics Inc

  • Impact of Sampling Media on Soil Gas Measurements

    Abstract To evaluate the vapor intrusion pathway for a building and to assess the associated human health risks, soil gas samples near the building site and under the building foundation may be collected. In order to meet risk assessment goals, the analytical laboratory is often required to report compounds of concern for these soil gas samples down to the part per billion ranges or lower. ...


    By Eurofins Air Toxics Inc

  • The 10 Key Factors in Selecting a Stack Sampling Firm

    Summary: This document is a summary of the key factors that you should take into consideration when hiring a stack testing firm.This has been prepared in conjunction with the ASTM criteria for standard practice of testing companies.The ASTM criteria has been supplemented, based on 125 years of direct testing experience, which is the combined years of experience of the individuals that contributed ...

  • Gas Safety in Confined Spaces

    Introduction An offshore worker ensures a vessel is safe to enter; a plant manager enters a small plant room; a contractor inspects the lining of a sewage pipe.  All these personnel face common dangers, despite working in widely different industries.  Gas-related injury poses a serious threat in any confined space where the free movement of air is limited. A confined space ...

  • Gas safety in confined spaces

    An engineer repairs buried cables; a plant manager enters a small plant room; a contractor inspects the lining of a sewage pipe.  All these personnel face a common danger, despite working in widely different industries.  Gas-related injury poses a serious threat in any confined space where the free movement of air is limited.  ...

  • Sample Handling Strategies for Accurate Lead-In-Soil Measurements in the Field and Laboratory

    ABSTRACT The inhomogenous lead-in-soil matrix can present serious obstacles to accurate sample collection and handling. In typical lead-in-soil measurement, particle size related errors in sampling and sample handling often exceed all other sources of error. The magnitude of error can vary widely depending on the particulate nature of the lead contaminant and the effectiveness of control ...

  • Low-Flow (Minimal Drawdown) Ground-Water Sampling Procedures

    Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water ...


    By Solinst Canada Ltd.

  • EPA studies identify techniques for critical leak testing prior to soil-vapor sampling

    Researchers at EPA’s National Risk Management Research Laboratory (NRMRL) in Ada, OK, are developing quality assurance (QA) measures for soil-gas and sub-slab sampling methods that help differentiate contaminant vapors due to vapor intrusion from background sources. Recent research focused on measures to identify leakage of ambient air into conventional vapor probes, which can significantly ...

  • Gas analysers support management of Swindon fire

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents. Arrangements have been made in England to bring together experts from the Environment Agency ...


    By Quantitech Ltd

  • Quantitative leak testing for soil gas wells using a commercially available helium tracer shroud

    In this paper we present design considerations, use, procedures and validation data for a commercially available Helium tracer soil gas sampling shroud that can be rented from an internationally accredited environmental testing laboratory with soil gas measurement capabilities. Soil Gas Sampling using the Helium shroud technique described in Appendix C, page 57, CA DTSC Soil Gas Advisory Document ...

  • FTIR gas analyzers support management of fire at UK waste facility

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents.  Arrangements have been made in England to bring together experts from the Environment ...


    By Gasmet Technologies Oy

  • The World’s Largest Gas to Liquids Facility Runs on Thermo Scientific SampleManager LIMS

    Established by Shell and Qatar Petroleum in 2006, Pearl GTL is the largest gas to liquids facility on the planet. Gas to liquids (GTL) is the conversion of natural gas to liquid fuels and other products, including gasoil, naphtha, kerosene, normal-paraffin and lubricants. Pearl GTL has a capacity of 140,000 barrels per day of these products and 120,000 barrels per day of liquefied petroleum gas, ...

  • FTIR analyser improves anaesthetic gas detection at Torbay Hospital

    A unique gas measurement technology has enabled South Devon Healthcare’s Pharmacy Manufacturing Unit (PMU) at Torbay Hospital to conduct highly effective and detailed analysis of anaesthetic gases in a variety of hospital locations. The primary function of the PMU’s quality control department is to check active ingredient levels and sterility in manufactured pharmaceutical ...


    By Gasmet Technologies Oy

  • So Your Greenhouse Gas (GHG) Monitoring Plan is Complete... Now What?!?

    U.S. EPA's Greenhouse Gas Mandatory Reporting Rule (GHG MRR) codified at 40 CFR Part 98 required that facilities subject to the rule have a complete written GHG Monitoring Plan by April 1, 2010. At a minimum, the GHG Monitoring Plan must identify (1) methods used to collect GHG emissions information and supporting data, (2) personnel responsible for collecting the data, and (3) quality assurance, ...


    By All4 Inc.

  • A Comparison Between EPA Compendium TO-15 and EPA MEthod 8260B for VOC Determination of Soil Gas

    ABSTRACT Evaluations of vapor intrusion pathways of chemical contaminants often include soil gas measurements to assess the potential for indoor inhalation. No longer just a screening tool, soil gas measurements are requiring a level of quality and defensibility which should be incorporated in soil gas analytical protocols. While both EPA Compendium Method TO-15 and EPA SW-S46 Method 8260B ...


    By Eurofins Air Toxics Inc

  • St. Landry Parish Solid Waste Disposal District: Turning Landfill Gas Into Biofuel

    One of the pioneers in biogas use, St. Landry Parish Solid Waste Disposal District has used its landfill gas to fuel vehicles in their local Sheriff’s Department. Born out of the need to deal with open dumps in the late 1970s, the St Landry Parish Solid Waste Disposal District’s purpose was to deal with the growing problem. Before its creation, waste was collected by a ...


    By Waste Advantage Magazine

  • Food packaging designs tested using Systech Illinois gas analysis equipment - case study

    At the Loughry Campus, Systech Illinois' headspace gas analyzer and oxygen permeation analyzer are used in the testing of food packaging. Located in Cookstown, County Tyrone, Northern Ireland, Loughry Campus offers educational and training programmes in all elements of Food Management. Students have access to a purpose built food technology centre and laboratories where they can develop ...


    By Systech Instruments Ltd

  • System Description for Monitoring Volatile Hydrocarbons

    To help build a comprehensive Industrial Hygiene program, Buck Scientific introduces the IH910 vapor monitoring system utilizing our model 910 gas chromatograph and IH300 air sampling train. Designed to analyze hydrocarbons in air, such as degreasing solvents and paint vapors emitted during plant operations, the IH910 penetrates the 1mg/m3 detection barrier erected by other field portable gas ...


    By Buck Scientific Inc

  • Recent papers in groundwater remediation

    Computational cost is a critical issue for large-scale water resource optimization under uncertainty, since time-intensive Monte Carlo simulations are often required to evaluate over multiple parameter realizations. This paper presents an efficient approach for replacing most Monte Carlo simulations with efficient surrogate models within a noisy genetic algorithm (GA). The surrogates are trained ...


    By IWA Publishing

  • Sakhalin energy utilizes Thermo Scientific SampleManager LIMS for largest Russian LNG project ever - case study

    Sakhalin Energy is bringing onstream one of the largest integrated oil and gas projects in the world in Russia's Far East. The Sakhalin II Project combines partnership incorporating the recovery, production and transportation of oil and liquefied natural gas (LNG). Sakhalin Energy standardized on Thermo Scientific SampleManager LIMS (Laboratory Information Management System) for use in its main ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you