geotechnical equipment Articles

  • Soil Column Drainage Modelling Using a Geotechnical Centrifuge

    Equipment has been developed to facilitate supplying a soil column with water or draining a soil column under conditions of constant head while the soil column is under centrifugal forces in a geotechnical centrifuge. Accurate monitoring of the water mass transfer is also facilitated by the equipment. At the completion of a modelling sequence, the soil column may be partitioned for moisture ...


    By ASTM International

  • Geotechnical Geophysics: Seismic refraction and refraction microtremor (ReMi) surveys

    ReMi Surveys are superior to MASW Surveys in the following ways: Ambient (ie, traffic and aircraft) “noise” is a hindrance to MASW surveys, yet is readily embraced / utilized by “passive” ReMi surveys Longer ReMi data records (ie, 30 seconds vs 8 seconds or less with MASW) capture lower frequency events We introduce high frequency impulsive energy that ...


    By ECA Geophysics

  • Combination of TenCate corporate capabilities offer distinct advantage with both geotechnical and geosystems expertise - Case Study

    Mirafi and Geotube Technology combine for demanding, large-scale dewatering project in Brazil. Geotechnical projects come in a variety of sizes and scope — each presenting unique challenges. Many times these challenges are multi-faceted and require engineers to apply different disciplines and use a mix of products and methodologies to solve their project issues. ...

  • Case study - G200 detects N20 leak in sedation equipment at dental surgery

    About the customer Dental practice, Dover, England Challenge the customer faced A dental engineer was sent to investigate N2O problems at the dental surgery after complaints from staff about the effects of the gas. Previous passive monitoring in the surgery had indicated a time weighted average (TWA) of N2O at 90ppm, and a suspected leak in a faulty ...

  • Guidelines for specification writing for Deep Soil Mixing

    Abstract: Deep Soil Mixing (DSM) was recently introduced into the United States as a geotechnical and environmental construction method. Primarily, DSM is used for deep foundation improvements. With the onset of this new technology, the need for guidelines for specification writing and the interpretation of testing results arises. This need would include guidelines for specifying construction ...


    By Geo-Con, Inc.

  • ASTM Symposium on Design, Construction, and Testing of Deep foundation improvement; Stone columns and other related techniques Las Vegas, Nevada

    Abstract Deep Soil Mixing (DSM) was recently introduced into the United States as a geotechnical and environmental construction method. Primarily, DSM is used for deep foundation improvements. With the onset of this new technology, the need for guidelines for specification writing and the interpretation of testing results arises. This need would include guidelines for specifying construction ...


    By Geo-Con, Inc.

  • Random fields in SVSlope and SVFlux

    Geotechnical engineering, as a general practice, has always struggled with quantifying the significant amount of variability that can be present at any given site. There may be variability present in field sampling methods, equipment, lab testing procedures, level of training of field personnel, or many other such factors. One particular problematic aspect of slope stability analysis is the ...


    By SoilVision Systems Ltd.

  • National Grid, Croydon case study

    Morgan Est Contractors for National Grid Supply and installation of telemetred groundwater monitoring network, May 2006 - ongoing Hydro-Logic recently completed the supply and installation of borehole instrumentation and a telemetry monitoring system to monitor groundwater conditions in 28 observation wells located at 19 sites in the vicinity of Croydon. The project was required to ...


    By Hydro-Logic Services

  • Turbidity Warning System

    Morgan Est Contractors for National Grid Supply and installation of telemetred groundwater monitoring network, May 2006 ongoing Hydro-Logic recently completed the supply and installation of borehole instrumentation and a telemetry monitoring system to monitor groundwater conditions in 28 observation wells located at 19 sites in the vicinity of Croydon. The ...

  • National Grid, Croydon case study

    National Grid, Croydon Morgan Est Contractors for National Grid Supply and installation of telemetred groundwater monitoring network, May 2006 - ongoing Hydro-Logic recently completed the supply and installation of borehole instrumentation and a telemetry monitoring system to monitor groundwater conditions in 28 observation wells ...


    By Hydro-Logic Services

  • Interview with Ronald Ebelhar, 2015 Chairman of the ASTM Board

    Ron Ebelhar has provided leadership in civil engineering projects and ASTM technical committee work since the 1970s. This year, he brings his experience to his elected position as chairman of the ASTM board of directors. You have worked on dozens of engineering projects since getting your degrees in civil engineering. What are some of the most interesting and challenging jobs you ...


    By ASTM International

  • Incotec Bolivia CPT case study

    Vertek partner Incotec recently entered the cone penetration test business area with the purchase of a Vertek S4 Push System. Learn more about the geotechnical market in their home country of Bolivia and  ...

  • Boulder Concrete Cloth Erosion Repair

    Concrete Cloth provides an affordable solution for an eroded hard-to-access residential slope. After a period of heavy rainfall, a Boulder, Colorado, homeowner discovered severe erosion in his backyard at the end of his leach field (also known as a septic drain field). He had to find a way to repair this damage and stop it from happening again; nearly half of his lawn had dropped three ...


    By Nilex

  • Understanding Geographical Instrumentation

    Geographical instrumentation is one of the much heard terms especially in the field of building. Anywhere, where construction is carried out then services rendered for site examination plays an important role. It helps in identifying possible risks and also effectiveness present within the current site or structure.  Designing of the Site The basic step which is carried out ...


    By Soldata Limited

  • Case study - Redvale Energy Park pleased with GA3000 PLUS

    Application Continuous inline monitoring of incoming landfill gas Equipment GA3000 PLUS Location New Zealand Customer Revdale Energy Park Requirement The ...

  • GA3000 monitors graves in Korea case study

    Application Research into gases produced by animal carcasses Equipment GA3000 Location Korea Customer A Korean government research facility supplied and supported by ENInstrument. ...

  • Scanning for Leaks & Sinkhole Detection in a Retention Pond - Case Study

    In January 2015, one of our clients used AGI tools and software for leak and sinkhole detection in the liner of a retention pond in Tennessee. Process Our client’s customer had a retention pond that was designed to hold liquid, but it was leaking through a hole in the liner. The client used the ...


    By Advanced Geosciences, Inc.

  • Bali’s first modern landfill design case study

    Bangli Regional Landfill in Indonesia’s Bali province is located about 60km outside of Denpasar, the provincial capital and home to more than 500,000 residents. The region hosts Ngurah Rai International Airport—the main entry point into Bali—and numerous tourist destinations along Bali’s popular white sands beaches. When the Indonesian central government approved ...


    By NAUE GmbH & Co.KG

  • Case study - LFG pumping trials with Automatic Flare Systems (AFS)

    Application Landfill gas Equipment GA3000 Location United Kingdom Customer Automatic Flare Systems (AFS) Requirement Managing director at AFS, Steve Willacy said, “We want continuous landfill gas monitoring and analysis and to use a data logger to ...

  • Standard Chlorine of Delaware Remediation

    By designing a 70-foot deep barrier wall, Black & Veatch was able to cut off contaminant source areas from a creek near New Castle, Delaware. The groundwater treatment system that Black & Veatch designed prevents site contamination from reaching the underlying drinking water aquifer. The Standard Chlorine of Delaware Site is a 65 acre area including an abandoned chlorobenzene ...


    By Black & Veatch Corporation

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you