grit dewatering Articles

  • DMax grit washing and recycling video demonstrates recycling success

    Following the installation of the DMax grit recovery and recycling plant at the Coleshill Seeage treatment works in Birmingham, England there has been a video produced by CDEnviro to demonstrate the efficiency of the plant in reducing waste to landfill volumes.As previously reported the Dmax plant has helped Severn Trent to reduce their waste to landfill volumes arising from a variety of waste ...


    By CDEnviro

  • Processing Wastewater Sludge Using Dewatering Containers

    The relative cost of dewatering equipment varies widely and is directly related to the processing rate. For smaller utilities that need to dewater sludge in batches, dewatering containers are an alternative that can be relatively inexpensive and simple when compared to other technologies on the market. The most common type of dewatering container is based on a roll-off box design, although any ...


    By Flo Trend® Systems, Inc.

  • Implementation of an Innovative, Severe Duty, Grit Removal System at the Blue Plains Advanced Wastewater Treatment Plant in Washington, D.C.

    The District of Columbia Water and Sewer Authority’s Blue Plains Advanced Wastewater Treatment Plant has headworks facilities capable of treating an average daily design flow of 370 million gallons per day (mgd) and a design peak flow of over 1.0 billion gallons per day (1,000 mgd). The facilities are prone to very heavy grit loads during wet weather events, and the facilities are forced to ...

  • Development of wet pre-treatment and pulper technology

    Since 1984 BTA is involved in activities in the area of waste pre-treatment. This process was first implemented in 1986 in a pilot plant. The patented BTA-Process is consisting of the following main steps: - Wet pre-treatment of waste with separation of the contaminants and production of a pumpable suspension- Sand separation by a hydrodynamic grit removal system- Digestion of the suspension in ...


    By ORBIT e.V.

  • Newport News, VA case study

    The Challenge - Retrofit The James River Treatment Plant (JRTP) is one of nine major treatment plants operated by the Hampton Roads Sanitation District (HRSD) in southeast Virginia. The JRTP discharges into the James River, a major tributary to the lower Chesapeake Bay. To meet the goals of the James River Waste Load Allocation, the Virginia Department of Environmental Quality issued HRSD a ...

  • Heard County Water Authority - Holistic approach - Case Study

    Location: Franklin, Georgia Owner: Heard County Water Authority Engineer: Hayes, James, & Associates Contractor: P.F. Moon Outdated Equipment The Heard County Water Authority serves over 380 connections in and around Franklin, Georgia. With a growing population, Heard County was beginning to  exceed the capacity of the existing wastewater treatment ...


    By WesTech Engineering, Inc.

  • New technology for sludge management reduces waste to landfill by 80%

    The first batch of results from a new sludge management and waste reduction system at Severn Trent's Coleshill Sewage Treatment Works in Birmingham, England show a consistent 80% reduction in waste to landfill volumes. The DMax system has specifically been developed by CDE Ireland Ltd to process a variety of wastes as detailed below. This list is not exhaustive and represents the material for ...


    By CDEnviro

  • Municipal waste water treatment plant case study

    A municipal WWTP in the North of England was experiencing significant problems with accumulations of FOG in the Wetwell at the head of the treatment plant. The FOG would form a solid cap over the well several feet thick. This put considerable strain on the pumping gear, interrupted the performance of the float switches and required regular manual intervention from the staff. High costs were also ...


    By Cleveland Biotech Ltd.

  • Case study - Daphne utilities water reclamation facility

    With significant TSS and BOD reductions from their Salsnes Filter system, Daphne Utilities has restored previously lost plant capacity. More than that, loading reductions have cut back aerator maintenance and lowered energy consumption of blowers. Project Background Daphne Utilities, situated on the eastern shore of Mobile Bay in Alabama, provides water, sewer and natural ...

  • Sludge Disposal that’s Sustainable, Safe and Economically Viable

    The Kemwater Recycling Process – KREPRO for treatment of sewage sludge is based on a completely new separation technology, which uses existing knowledge in an innovative way. It reduces both the organic and inorganic content of the sludge. The organic content is re-duced by about 30% and the inorganic about 70% if digested sludge is treated. All metals and salts are dissolved; the remaining ...


  • Process Alternative Comparisons Assisted with Biowin Modeling

    ABSTRACTPermitted at 6.4 mgd on an annual average day basis, the City of Avondale Wastewater Treatment Plant currently employs Nitrification/Denitrification process to produce effluent with maximum total nitrogen of 10 mg/L. The process consists of Aeration Basins followed by Secondary Clarifiers to treat the screened influent after the grit removal. On the solids handling side, the Wasted ...

  • A Reinvigorated Approach to Operational Safety in the Design of a New Digestion System for Spokane, Washington

    ABSTRACTThe failure of Digester No. 3 at the Riverside Park Water Reclamation Facility (RPWRF) in Spokane, Washington triggered a host of changes to many aspects of project implementation, as well as daily operation. Planning, design, construction and startup of  improvements now emphasize improved communication and collaboration between the design team and plant staff, as well as a ...

  • Wastewater treatment facility uses ‘monsters’ to better manage screening, odor and trash

    As wastewater pours into the Cobourg Water Pollution Control Facility located on the outskirts of this Canadian town, it comes loaded with organics, trash, debris and chemicals. A large perforated plate screen system, called a Monster Separation SystemTM, is the plant’s first line of defense and removes all unwanted solids in order to protect downstream processes.Managers at the facility report ...


    By JWC Environmental

  • Strategic Abatement of Emission to Economically Support Development of High Profile Real Estate Adjacent to a Wastewater Reclamation Facility

    ABSTRACTThe Des Moines Wastewater Reclamation Authority operates a 97-million gallon per day regional wastewater reclamation facility (WRF) largely constructed in the mid 1980s to serve the greater Des Moines, Iowa metropolitan area. Originally constructed in a largely rural area, current plans for the area around the WRF establish a need for emissions control to reduce offsite odor impacts, in ...

  • The Devil is in The Details: Full-Scale Optimization of the EBPR Process at the City of Las Vegas WPCF

    ABSTRACTTo optimize the enhanced biological phosphorus (P) removal (EBPR) at the City of Las Vegas’ Water Pollution Control Facility, the effects of dissolved oxygen (DO) level, hydraulic retention time in aeration basin and the operation mode of UCT versus A2O on phosphorus removal performance were investigated. DO levels in the range of 0.5 to 3.5 mg/L in the aeration basin did not have ...

  • What is Wastewater?

    What is wastewater? Wastewater, the waste discharge that first comes to mind in any discussion of stream pollution, is the discharge of domestic wastewater, which contains a large amount of organic waste. Industry also contribute substantial amounts of organic waste, some of which comes from vegetable and fruit packing; dairy processing; meat packing; tanning; processing of poultry, ...

  • Full Scale Test on Chemical P Removal During a Step Feed BNR Study at John E. Egan Water Reclamation Plant

    ABSTRACTA full scale nutrient removal study was conducted at the 30-MGD John E. Egan Water Reclamation Plant with a single-stage nitrification activated sludge process and sand filtration. One quarter of the plant’s secondary treatment capacity was used in the study. Simultaneous nitrogen removal through a step feed BNR process and phosphorus (P) removal by chemical precipitation with ferric ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you