hcl scrubber Articles

  • Automotive: Scrubber system removes HCL from Exhaust case study

    Although Indiana’s environmental protection agency has not yet added hydrochloric acid (HCl) standards to its Title 5 regulation of emissions sources, Allomatic Products Co., Sullivan, IN, was determined to erase HCI vapors from its plant discharge. In the mixed industrial/ residential neighborhood where its manufacturing plant is located, Allomatic wanted to be known as a good neighbor. ...


    By CR Clean Air Group, LLC

  • 3-K-Series Tellerette® Packing for HCl removal in a Crossflow Scrubber

    A number of sources in the wastewater treatment process such as the headworks, aeration tanks, settling tanks andd ewatering press can produce high-intensity odors fromgaseous sulfide emissions. The most common sulfides are hydrogen sulfide (H2S) and methyl mercaptan (CH3SH.)The highlighted installation was for a major municipalityin the southeast and utilizes our new high efficiency ...

  • Metals: Scrubber System Removes HCL from Exhaust Case Study

    Although Indiana’s environmental protection agency has not yet added hydrochloric acid (HCl) standards to its Title 5 regulation of emissions sources, Allomatic Products Co., Sullivan, IN, was determined to erase HCI vapors from its plant discharge. In the mixed industrial/ residential neighborhood where its manufacturing plant is located, Allomatic wanted to be known as a good neighbor. ...


    By CR Clean Air Group, LLC

  • Wet Scrubbing HCL & SiCl4 Fumes

    This two-stage scrubbing system utilizes a jet venturi scrubber in conjunction with a counter current packed tower including entrainment mist eliminator. It was designed to eliminate the HC1 (hydrochloric acid) fumes generated when S1C14 (silicon tetrachioride) comes in contact with moisture cluring processing operations at a zirconium processing tank farrn, and also the remaining smail amount of ...


  • HCL System Exceeds Current Regulations

    Chemron manufactures high-quality specialty chemicals and surfactants for personal care products, industrial, institutional, oil field, mining, coatings, lubricants and water treatment. Some of the operations result in the creation of hydrochloric acid with high variable rates. As expressed by Bill Frost, of Chemron: “Chemronmaintains a strong environmental commitment, which views regulations as ...


  • Sale of by-Product HCl Covers Cost of Emission Control System

    Problem: Some of the specialty chemical processes at a major chemical manufacturer's plant result in considerable HCl loading in the off-gas. The HCl must be removed before the off-gas can be discharged to the atmosphere. Production of saleable by-product HCl solution was an important goal when looking for a high-efficiency HCl removal system. The company wanted to achieve a very low ...


  • Chemical Industry: Wet Scrubbing HCL & SiCl4 Fumes Case Study

    This two-stage scrubbing system utilizes a jet venturi scrubber in conjunction with a counter current packed tower including entrainment mist eliminator. It was designed to eliminate the HCl (hydrochloric acid) fumes generated when SiC14 (silicon tetrachloride) comes in contact with moisture during processing operations at a zirconium processing tank farm, and also the remaining small amount of ...


    By CR Clean Air Group, LLC

  • Case History - Sale of By-product HCl Covers Cost of Emission-Control System

    Problem: Some of the specialty chemical processes at a major chemical manufacturer's plant result in considerable HCl loading in the off-gas. The HCl must be removed before the off-gas can be discharged to the atmosphere. Production of saleable by-product HCl solution was an important goal when looking for a high-efficiency HCl removal system. The company wanted to achieve a very low ...


  • Chemical Industry: Sale of by-Product HCl Covers Cost of Emission Control System Problem Case Study

    Some of the specialty chemical processes at a major chemical manufacturer’s plant result in considerable HCl loading in the off-gas. The HCl must be removed before the off-gas can be discharged to the atmosphere. Production of saleable by-product HCl solution was an important goal when looking for a high-efficiency HCl removal system. The company wanted to achieve a very low level of ...


    By CR Clean Air Group, LLC

  • Chemical Industry: HCL System Exceeds Current Regulations Emission control meets requirements while recovering by-product for sale Case Study

    Chemron manufactures high-quality specialty chemicals and surfactants for personal care products, industrial, institutional, oil field, mining, coatings, lubricants and water treatment. Some of the operations result in the creation of hydrochloric acid with high variable rates. As expressed by Bill Frost, of Chemron: “Chemron maintains a strong environmental commitment, which views ...


    By CR Clean Air Group, LLC

  • Automotive: At Sandvik Coromant, Clean Air Group Scrubber Handle Emissions Emergencies case study

    Mr. Tahvanainen heads up a staff of eight maintenance personnel and a supervisor. He is a mechanical engineer with a background in power production and thermodynamics. Editorial Background: Sandvik Coromant of Fair Lawn, NJ is part of Sandvik’s tooling division. The overall Sandvik Corporation employs 35,000 in one hundred and thirty (130) countries. ...


    By CR Clean Air Group, LLC

  • Heavy metals in wet scrubber residue from a medium–sized (32 MW) municipal district heating plant incinerating wood and peat in a fluidised bed boiler

    Due to the low total concentrations of heavy metals and extractable compounds, it is recommended that the wet scrubber residue be used as a construction agent instead of being disposed of in landfills. According to five–stage sequential extraction, the highest concentrations of most of the heavy metals occurred in the residual fraction (i.e., HF + HNO3 + HCl), which means that ...


    By Inderscience Publishers

  • Abbott Labs North Chicago, IL case study

    In process manufacturing of a ScrubPac Thermal Oxidizer Scrubber System with Quencher and pump skid components shown. Scrubber system designed to remove HCL for meeting Pharmaceutical MACT standards. System designed to clean over 61000 ACFM of 1700 deg. F oxidizer exhaust ...


    By Bionomic Industries Inc.

  • Pharmaceutical: HCI Fumes Eliminated at Two Plants Case Study

    Little Maintenance Needed On Jet-Venturi Scrubbers; New Solutions Of Plant Problems: Two plants -Tenneco Chemicals, Reading, Pennsylvania and Hoffmann-La Roche, Nutley, New Jersey – are preventing the escape of HCl fumes from their plants by the use of jetventuri wet scrubbers and separators. Fiberglass-reinforced polyester construction of scrubber units is major factor that ...


    By CR Clean Air Group, LLC

  • Integrated maximum efficiency air pollution control system

    A major uranium refiner required an air pollution control system to control emissions from their hazardous incinerator. The presence of radioactive material demanded that outlet emissions approach non-detectable levels. Macrotek was contracted to design and supply the system. Advanced, cutting edge technology was used to design a system with the lowest possible emissions, which has been ...


    By Macrotek Inc.

  • Multiple stage scrubbing and adsorption system for Incinerator exhaust at an industrial waste processing plant

    Challenge Monroe Environmental was called upon to purify a 20,000 CFM exhaust stream that was being discharged from an industrial waste incinerator at 2000° F. The pollutants that needed to be removed were: Fine Ash Particulate HCL Gas Mercury Dioxins The combination of soluble and solid pollutants, coupled with the ...

  • Case study - Mobile remediation system

    OVERVIEW A large consulting and contracting firm owns and operates several ex-situ Thermal Desorption Units (TDUs). Each single-load Thermal Desorption Unit has the capacity of desorbing 15 tons of soil per hour at a temperature of 400°F - 900°F. These Thermal Desorber Units have been designed to operate on both chlorinated and non-chlorinated RCRA, CERCLA, and private industry ...

  • Liquid waste off-gas treatment - Case Study

    Application Biffa Waste Services operate a major waste disposal site at Kilsyth in Scotland where they handle many types of industrial liquid effluent. This can give rise to a range of emissions from both the tank farm and the road tanker deliveries. In addition, significant NO2 and nitric acid fume releases can arise from process upset conditions. ERG provided an emergency NO2 ...

  • Case study - Pharmacuetical Company chooses the QUADRANT NRV Thermal Oxidizer

    Faced with meeting the needs of their Pharma Industry MACT Standards, one Fortune 100 Pharmaceutical Manufacturer called on Catalytic Products International, Inc. The challenge for Catalytic Products International was to design a system that was able to process the ultra-high LEL (high concentration of VOC’s) and deal with corrosive acids produced in the process off gas and the ...

  • Pharmaceutical Gas Scrubbing - Case Study

    Application Novartis Ringaskiddy Limited needed to scrub a variety of aggressive acid and volatile organic compounds from the vents of pharmaceutical batch reactors. These make up part of the manufacturing process of a range of pharmaceutical ingredients. The compounds included HCl and methyl bromide fumes within air or nitrogen streams. System description ...