hg analysis instrument Articles

  • Two Detector Solution to Analyzing Sulfur

    Sulfur compounds are reactive, corrosive to pipes, and destructive to catalysts in petroleum refineries. Sulfur emission are strictly regulated globally. When released into the atmosphere sulfur dioxide converts to sulfuric acid resulting in adverse effects on human health and the environment. Sulfur detection is found useful in many other industries; therefore, detection of sulfur compounds in ...


    By Restek Corporation

  • Mercury Analysis

    Characteristics of Mercury What is Mercury? Mercury is a naturally occurring silver-colored metallic element noted for its occurrence as a liquid at room temperature and toxic to living organisms. This silvery, opaque liquid metal is very dense, yet has a high surface tension that causes it to form tiny perfect spheres in the pores of the rocks it is found in. It is ...


    By HORIBA Europe GmbH

  • Tekran instruments—monitoring around the world

    Tekran provides trace-level mercury analytical and monitoring technology for a variety of applications including laboratory-based sample analysis, continuous point-source emissions and ambient air monitoring. This article focuses on and highlights the results of an application of Tekran’s Ambient Air Mercury Speciation System. In contrast to most other heavy metals, mercury (Hg) and mercury ...

  • Determination of macro, micro nutrient and trace element concentrations in Indian medicinal plants using instrumental neutron activation analysis and atomic absorption spectroscopy techniques

    Specific parts (fruits and seeds) of different medicinal plants often used in Indian Ayurvedic system were analysed for 18 elements (K, Mn, Na, Fe, Zn, Cu, Co, Br, Sm, Cl, La, Al, Cr, Ca Cd, Ni, Pb and Hg) by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the ...


    By Inderscience Publishers

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Analysis of Whole Blood for Trace Lead (Pb) by Graphite Furnace AAS

    Toxic effects from heavy metals (Pb, As, Se, Cd, Bi, Sn, Tl, and Hg) have been characterized in medical literature for decades. Originally, complex extractions were performed to isolate the poisonous components from the complex biological matrices: blood, serum, urine and tissues. Recently, optical emission and atomic absorption spectroscopy techniques were developed to determine these toxic ...


    By Buck Scientific Inc

  • A comparison of two solid phase extraction methods for the analysis of Polyaromatic Hydrocarbons in butter

    Background Polyaromatic hydrocarbons (PAHs) are ubiquitous in the environment, resulting from both natural and manmade sources of combustion. Farm animals, such as cows, can become exposed to them through both consumption of contaminated feed and water, and inhalation of contaminated atmosphere ...


    By Sigma-Aldrich Co., LLC

  • Using FIMS to determine mercury content in sewage sludge, sediment and soil samples

    Tim Flow Injection Mercury System (FIMS) is a dedicated system that integrates flow injection mercury cold vapor generation with a very sensitive detector. The exceptional system stability and the long path measurement cell provide instrumental detection limits as low as 5 ng/L using a sample volume of 5(H) jxL. The improved sensitivity of the FIMS permits sample dilution, therefore reducing the ...


    By PerkinElmer, Inc.

  • INAA and AAS study of essential trace elements in ayurvedic Indian medicinal plants

    Specific parts (leaves and fruits) of different medicinal plants often used in Indian ayurvedic system were analysed for 18 elements (K, Mn, Na, Fe, Zn, Cu, Co, Br, Sm, Cl, La, Al, Cr, Ca Cd, Ni, Pb and Hg) by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the ...


    By Inderscience Publishers

  • Atmospheric chemical element pollution in an urban water-associated environment

    Nowadays, sustainability has become a complicated issue mainly in urban centres. Owing to the atmospheric emissions, the incorporation of toxic chemical elements is still not well known for urban water-associated ecosystems. Tillandsia bromeliads were employed as passive biomonitors of air pollution. Otherwise, the tank bromeliad Canistropsis billbergioides, native to the Atlantic Forest, was ...


    By Inderscience Publishers

  • Detecting Mercury in Water

    Determination of Mercury (Hg) in Water by Hand-Held, Portable Cold Vapor Atomic Fluorescence SpectrometryWater is the most familiar and most abundant compound on Earth, making up 71% of its surface area.[1]It is a vital component for all known forms of life and is the aquatic habitat for thousands of species of microalgae, fish and shellfish. [2] With the presence of running water in our ...


    By Arizona Instrument LLC

  • Native plant bioaccumulation strategies: a baseline study for biomonitoring the Atlantic Forest

    The atmosphere may act as an important source of chemical elements for the Atlantic Forest, one of the hottest world biodiversity hotspots. However, chemical responses for chemical element availability are not expected to be equal for each plant species. In this sense, the present work encompasses a baseline study for biomonitoring purposes based on the identification of different strategies of ...


    By Inderscience Publishers

  • The scalp hair as a monitor for trace elements in biomonitoring of atmospheric pollution

    The chemical element contents in scalp hair of 80 apparently healthy 15- to 58-year-old citizens (36 females and 44 males) of a non-industrial region in the Central European part of Russia were investigated by Instrumental Neutron Activation Analysis (INAA) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The summary of statistics, arithmetic mean, standard deviation, ...


    By Inderscience Publishers

  • Human bone as a biological material for environmental monitoring

    The effect of age and gender on major, minor and trace element contents in the intact rib-bone of 84 apparently healthy 15?58 year-old citizens (38 females and 46 males) of a non-industrial region in the Central European part of Russia was investigated by Instrumental Neutron Activation Analysis (INAA) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The summary of ...


    By Inderscience Publishers

  • The application of Flow Injection Technology to automating cold vapor MERCURY analyses

    This document describes the application of flow injection technology to cold vapor mercury analyses. It can be obtained from PerkinElmer by requesting method number ENVA-100. Appendices 1 and 2 show letters from the US EPA indicating acceptability through the Alternate Test Program for both drinking water and wastewater sample analysis. 1.0 Scope and Application 1.1 This ...


    By PerkinElmer, Inc.

  • Mining Water Quality Application

    Isaac Plains Coal Mine Isaac Plains is an open cut coal mine, in Northern Queensland, Australia. The Isaac Plains Project operates under an Environmental Authority (EA). One of the environmental monitoring requirements which must be met is monitoring water. These include potable water, mine affected water, natural creek flows, water releases, groundwater and the receiving environment. The ...


    By ANDalyze

  • Innovation in Offshore Separation Process

    CLOV is a deep-sea oil production project offshore Angola. Sulzer helped to lower the cost of the floating production, storage, and offloading (FPSO) ship. There, Sulzer’s patented distributor technology and state-of-the-art pumps are brought to life by Total’s innovative wash tank process. This combination achieves significant cost savings on the FPSO design. With a processing ...


    By Sulzer

  • Annual European Union greenhouse gas inventory 1990–2014 and inventory report 2016

    ES.1 Background information on greenhouse gas inventories and climate change The European Union (EU), as a party to the United Nations Framework Convention on Climate Change (UNFCCC), reports annually on greenhouse gas (GHG) inventories for the years between 1990 and the current calendar year (t) minus two (t–2), for emissions and removals within the area covered by its Member ...

  • Some notes about Fats and Oils in Food and about FAME and FAMEWAX

    In Europe, the last transition periods named in REGULATION (EU) No 1169/2011 on the provision of food information to consumers are running out on Dec. 13th, 2016. Since then, a nutrition declaration is mandatory for nearly all packed food in Europe, wherein the amounts of fat, saturates, carbohydrate, sugars, protein and salt have to be included. The content of the mandatory nutrition ...


    By Restek Corporation

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you